Quantification of intramyocardial hemorrhage volume using magnetic resonance imaging with three-dimensional T1-weighted sequence in patients with ischemia-reperfusion injury: a semi-automated image processing technique
- 14 September 2019
- journal article
- research article
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 36 (1) , 111-119
Abstract
Although intramyocardial hemorrhage (IMH) is a poor prognostic factor caused by ischemia reperfusion injury, little evidence is available regarding the association between IMH volume and biomarkers. In the present study, we measured IMH volume using three-dimensional (3D) T1-weighted magnetic resonance imaging (T1-MRI) and investigated its association with biomarkers. Moreover, the accuracy of semi-automatic measurement of IMH volume was validated. We retrospectively enrolled 33 consecutive patients (mean age 67 ± 11 years) who underwent cardiac MRI after reperfusion therapy for acute myocardial infarction. IMH was observed in 4 patients (12.1%). Receiver operating characteristics (ROC) analysis of creatine kinase (CK) and CK-muscle/brain (CK-MB) tests for detecting IMH were performed. IMH volume measured using semi-automatic methods by a 2 standard deviation (SD) threshold was compared to manual measurements using the Spearman’s correlation coefficient (ρ) and Bland–Altman analyses. ROC analysis revealed optimal cutoff values of CK: 2460 IU/l and CK-MB: 231 IU/l (area under the curve: 0.95 and 0.91; sensitivity: 86% and 79%; specificity: 100% for both). IMH volume with the 2SD threshold correlated with that of the manual measurement [5.84 g (3.30 to 9.00) g vs. 8.07 g (5.37 to 9.33); ρ: 0.85, p < 0.01; bias (limit of agreement): − 0.01 g (− 0.51 to 0.49); intraclass correlation coefficients 0.84 (0.75 to 0.90)]. Our findings could help identify the risk of IMH after reperfusion therapy with biomarkers. 3D T1-MRI can semi-automatically provide accurate IMH volume without being time-consuming.Keywords
Funding Information
- Japanese Circulation Society
This publication has 28 references indexed in Scilit:
- Correction with blood T1 is essential when measuring post-contrast myocardial T1 value in patients with acute myocardial infarctionJournal of Cardiovascular Magnetic Resonance, 2013
- Investigation of the freely available easy-to-use software ‘EZR’ for medical statisticsBone Marrow Transplantation, 2012
- Auto‐Threshold quantification of late gadolinium enhancement in patients with acute heart diseaseJournal of Magnetic Resonance Imaging, 2012
- Assessment of intramyocardial hemorrhage by T1-weighted cardiovascular magnetic resonance in reperfused acute myocardial infarctionJournal of Cardiovascular Magnetic Resonance, 2012
- Serum N-Terminal Pro-B-Type Natriuretic Peptide Levels at the Time of Hospital Admission Predict of Microvascular Obstructions after Primary Percutaneous Coronary Intervention for Acute ST-Segment Elevation Myocardial InfarctionJournal of Interventional Cardiology, 2010
- Reperfusion haemorrhage as determined by cardiovascular MRI is a predictor of adverse left ventricular remodelling and markers of late arrhythmic riskHeart, 2010
- Pathogenesis of Myocardial Ischemia-Reperfusion Injury and Rationale for TherapyThe American Journal of Cardiology, 2010
- Microvascular ObstructionJACC, 2010
- Impact of myocardial haemorrhage on left ventricular function and remodelling in patients with reperfused acute myocardial infarctionEuropean Heart Journal, 2009
- Magnetic resonance imaging of haemorrhage within reperfused myocardial infarcts: possible interference with iron oxide-labelled cell tracking?European Heart Journal, 2006