Hideo Arai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hideo Arai has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Masateru Kawakubo
Department of Science and Engineering, Saga University, Honjo-machi, Saga-shi 840-8502, Saga, Japan
9 shared publications Toshiaki Kadokami
Department of Cardiology, Fukuokaken Saiseikai Futsukaichi Hospital, 3-13-1 Yumachi Chikushino, Fukuoka, Japan
9 shared publicationsHiroshi Nishimura
Department of Radiology, Fukuokaken Saiseikai Futsukaichi Hospital, 3-13-1 Yumachi Chikushino, Fukuoka, Japan
7 shared publicationsKenichi Sanui
Department of Radiology, Fukuokaken Saiseikai Futsukaichi Hospital, 3-13-1 Yumachi Chikushino, Fukuoka, Japan
6 shared publications- Hideaki Yokoo
Department of Human Pathology Gunma University Graduate School of Medicine Maebashi Japan
2 shared publications Masateru Kawakubo
Department of Health Sciences, Faculty of Medical Sciences Kyushu University Fukuoka Japan
2 shared publications
Latest Publications
- Open Access
- 9 August 2024
- Published by Elsevier in Radiology Case Reports
- Vol. 19 (11) , 4708-4712
Relevance of increased negative T waves in apical hypertrophic cardiomyopathy with progressive myocardial damage: Insights from repeat cardiac magnetic resonance studies
- 9 August 2024
- Published by Elsevier in Radiology Case Reports
- Vol. 19 (11) , 4708-4712
Open AccessRelevance of increased negative T waves in apical hypertrophic cardiomyopathy with progressive myocardial damage: Insights from repeat cardiac magnetic resonance studies
- Open Access
- 10 August 2023
- Published by Elsevier in Radiology Case Reports
- Vol. 18 (10) , 3710-3715
Differentiation between mild and severe myocarditis using multiparametric cardiac magnetic resonance
- 10 August 2023
- Published by Elsevier in Radiology Case Reports
- Vol. 18 (10) , 3710-3715
Open AccessDifferentiation between mild and severe myocarditis using multiparametric cardiac magnetic resonance
- Open Access
- 21 April 2023
- Published by Elsevier in World Neurosurgery
- Vol. 175, e1075-e1088
Preoperative Novel Magnetic Resonance Fusion Imaging for Carotid Endarterectomy Patients with Contrast Contraindications: A Pilot Study
- 21 April 2023
- Published by Elsevier in World Neurosurgery
- Vol. 175, e1075-e1088
Open AccessPreoperative Novel Magnetic Resonance Fusion Imaging for Carotid Endarterectomy Patients with Contrast Contraindications: A Pilot Study
- 22 March 2023
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 58 (6) , 1813-1814
Editorial for “Image‐Based Biological Heart Age Estimation Reveals Differential Aging Patterns Across cardiac chambers”
- 22 March 2023
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 58 (6) , 1813-1814
Editorial for “Image‐Based Biological Heart Age Estimation Reveals Differential Aging Patterns Across cardiac chambers”
- Open Access
- 11 July 2022
- Published by MDPI AG in Journal of Imaging
- Vol. 8 (7) , 194
Cardiac Disease Classification Using Two-Dimensional Thickness and Few-Shot Learning Based on Magnetic Resonance Imaging Image Segmentation
Cardiac cine magnetic resonance imaging (MRI) is a widely used technique for the noninvasive assessment of cardiac functions. Deep neural networks have achieved considerable progress in overcoming various challenges in cine MRI analysis. However, deep learning models cannot be used for classification because limited cine MRI data are available. To overcome this problem, features from cine image settings are derived by handcrafting and addition of other clinical features to the classical machine learning approach for ensuring the model fits the MRI device settings and image parameters required in the analysis. In this study, a novel method was proposed for classifying heart disease (cardiomyopathy patient groups) using only segmented output maps. In the encoder–decoder network, the fully convolutional EfficientNetB5-UNet was modified to perform the semantic segmentation of the MRI image slice. A two-dimensional thickness algorithm was used to combine the segmentation outputs for the 2D representation of images of the end-diastole (ED) and end-systole (ES) cardiac volumes. The thickness images were subsequently used for classification by using a few-shot model with an adaptive subspace classifier. Model performance was verified by applying the model to the 2017 MICCAI Medical Image Computing and Computer-Assisted Intervention dataset. High segmentation performance was achieved as follows: the average Dice coefficients of segmentation were 96.24% (ED) and 89.92% (ES) for the left ventricle (LV); the values for the right ventricle (RV) were 92.90% (ED) and 86.92% (ES). The values for myocardium were 88.90% (ED) and 90.48% (ES). An accuracy score of 92% was achieved in the classification of various cardiomyopathy groups without clinical features. A novel rapid analysis approach was proposed for heart disease diagnosis, especially for cardiomyopathy conditions using cine MRI based on segmented output maps.
- 11 July 2022
- Published by MDPI AG in Journal of Imaging
- Vol. 8 (7) , 194
Open AccessCardiac Disease Classification Using Two-Dimensional Thickness and Few-Shot Learning Based on Magnetic Resonance Imaging Image Segmentation
Cardiac cine magnetic resonance imaging (MRI) is a widely used technique for the noninvasive assessment of cardiac functions. Deep neural networks have achieved considerable progress in overcoming various challenges in cine MRI analysis. However, deep learning models cannot be used for classification because limited cine MRI data are available. To overcome this problem, features from cine image settings are derived by handcrafting and addition of other clinical features to the classical machine learning approach for ensuring the model fits the MRI device settings and image parameters required in the analysis. In this study, a novel method was proposed for classifying heart disease (cardiomyopathy patient groups) using only segmented output maps. In the encoder–decoder network, the fully convolutional EfficientNetB5-UNet was modified to perform the semantic segmentation of the MRI image slice. A two-dimensional thickness algorithm was used to combine the segmentation outputs for the 2D representation of images of the end-diastole (ED) and end-systole (ES) cardiac volumes. The thickness images were subsequently used for classification by using a few-shot model with an adaptive subspace classifier. Model performance was verified by applying the model to the 2017 MICCAI Medical Image Computing and Computer-Assisted Intervention dataset. High segmentation performance was achieved as follows: the average Dice coefficients of segmentation were 96.24% (ED) and 89.92% (ES) for the left ventricle (LV); the values for the right ventricle (RV) were 92.90% (ED) and 86.92% (ES). The values for myocardium were 88.90% (ED) and 90.48% (ES). An accuracy score of 92% was achieved in the classification of various cardiomyopathy groups without clinical features. A novel rapid analysis approach was proposed for heart disease diagnosis, especially for cardiomyopathy conditions using cine MRI based on segmented output maps.
- 28 April 2022
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 57 (1) , 189-190
Editorial for “First‐Pass Myocardial Perfusion With Increased Anatomic Coverage at 3T Using Autocalibrated Multiband Imaging”
- 28 April 2022
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 57 (1) , 189-190
Editorial for “First‐Pass Myocardial Perfusion With Increased Anatomic Coverage at 3T Using Autocalibrated Multiband Imaging”
- Open Access
- 27 January 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (3) , 1401
Assessment of Bi-Ventricular and Bi-Atrial Areas Using Four-Chamber Cine Cardiovascular Magnetic Resonance Imaging: Fully Automated Segmentation with a U-Net Convolutional Neural Network
Four-chamber (4CH) cine cardiovascular magnetic resonance imaging (CMR) facilitates simultaneous evaluation of cardiac chambers; however, manual segmentation is time-consuming and subjective in practice. We evaluated deep learning based on a U-Net convolutional neural network (CNN) for fully automated segmentation of the four cardiac chambers using 4CH cine CMR. Cine CMR datasets from patients were randomly assigned for training (1400 images from 70 patients), validation (600 images from 30 patients), and testing (1000 images from 50 patients). We validated manual and automated segmentation based on the U-Net CNN using the dice similarity coefficient (DSC) and Spearman’s rank correlation coefficient (ρ); p < 0.05 was statistically significant. The overall median DSC showed high similarity (0.89). Automated segmentation correlated strongly with manual segmentation in all chambers—the left and right ventricles, and the left and right atria (end-diastolic area: ρ = 0.88, 0.76, 0.92, and 0.87; end-systolic area: ρ = 0.81, 0.81, 0.92, and 0.83, respectively; p < 0.01). The area under the curve for the left ventricle, left atrium, right ventricle, and right atrium showed high scores (0.96, 0.99, 0.88, and 0.96, respectively). Fully automated segmentation could facilitate simultaneous evaluation and detection of enlargement of the four cardiac chambers without any time-consuming analysis.
- 27 January 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (3) , 1401
Open AccessAssessment of Bi-Ventricular and Bi-Atrial Areas Using Four-Chamber Cine Cardiovascular Magnetic Resonance Imaging: Fully Automated Segmentation with a U-Net Convolutional Neural Network
Four-chamber (4CH) cine cardiovascular magnetic resonance imaging (CMR) facilitates simultaneous evaluation of cardiac chambers; however, manual segmentation is time-consuming and subjective in practice. We evaluated deep learning based on a U-Net convolutional neural network (CNN) for fully automated segmentation of the four cardiac chambers using 4CH cine CMR. Cine CMR datasets from patients were randomly assigned for training (1400 images from 70 patients), validation (600 images from 30 patients), and testing (1000 images from 50 patients). We validated manual and automated segmentation based on the U-Net CNN using the dice similarity coefficient (DSC) and Spearman’s rank correlation coefficient (ρ); p < 0.05 was statistically significant. The overall median DSC showed high similarity (0.89). Automated segmentation correlated strongly with manual segmentation in all chambers—the left and right ventricles, and the left and right atria (end-diastolic area: ρ = 0.88, 0.76, 0.92, and 0.87; end-systolic area: ρ = 0.81, 0.81, 0.92, and 0.83, respectively; p < 0.01). The area under the curve for the left ventricle, left atrium, right ventricle, and right atrium showed high scores (0.96, 0.99, 0.88, and 0.96, respectively). Fully automated segmentation could facilitate simultaneous evaluation and detection of enlargement of the four cardiac chambers without any time-consuming analysis.
- Open Access
- 1 October 2020
- Published by Elsevier in Radiology Case Reports
- Vol. 15 (10) , 1954-1959
Assessing myocardial circumferential strain using cardiovascular magnetic resonance after magnetic resonance-conditional cardiac resynchronization therapy
- 1 October 2020
- Published by Elsevier in Radiology Case Reports
- Vol. 15 (10) , 1954-1959
Open AccessAssessing myocardial circumferential strain using cardiovascular magnetic resonance after magnetic resonance-conditional cardiac resynchronization therapy
- 14 September 2019
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 36 (1) , 111-119
Quantification of intramyocardial hemorrhage volume using magnetic resonance imaging with three-dimensional T1-weighted sequence in patients with ischemia-reperfusion injury: a semi-automated image processing technique
Although intramyocardial hemorrhage (IMH) is a poor prognostic factor caused by ischemia reperfusion injury, little evidence is available regarding the association between IMH volume and biomarkers. In the present study, we measured IMH volume using three-dimensional (3D) T1-weighted magnetic resonance imaging (T1-MRI) and investigated its association with biomarkers. Moreover, the accuracy of semi-automatic measurement of IMH volume was validated. We retrospectively enrolled 33 consecutive patients (mean age 67 ± 11 years) who underwent cardiac MRI after reperfusion therapy for acute myocardial infarction. IMH was observed in 4 patients (12.1%). Receiver operating characteristics (ROC) analysis of creatine kinase (CK) and CK-muscle/brain (CK-MB) tests for detecting IMH were performed. IMH volume measured using semi-automatic methods by a 2 standard deviation (SD) threshold was compared to manual measurements using the Spearman’s correlation coefficient (ρ) and Bland–Altman analyses. ROC analysis revealed optimal cutoff values of CK: 2460 IU/l and CK-MB: 231 IU/l (area under the curve: 0.95 and 0.91; sensitivity: 86% and 79%; specificity: 100% for both). IMH volume with the 2SD threshold correlated with that of the manual measurement [5.84 g (3.30 to 9.00) g vs. 8.07 g (5.37 to 9.33); ρ: 0.85, p < 0.01; bias (limit of agreement): − 0.01 g (− 0.51 to 0.49); intraclass correlation coefficients 0.84 (0.75 to 0.90)]. Our findings could help identify the risk of IMH after reperfusion therapy with biomarkers. 3D T1-MRI can semi-automatically provide accurate IMH volume without being time-consuming.
- 14 September 2019
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 36 (1) , 111-119
Quantification of intramyocardial hemorrhage volume using magnetic resonance imaging with three-dimensional T1-weighted sequence in patients with ischemia-reperfusion injury: a semi-automated image processing technique
Although intramyocardial hemorrhage (IMH) is a poor prognostic factor caused by ischemia reperfusion injury, little evidence is available regarding the association between IMH volume and biomarkers. In the present study, we measured IMH volume using three-dimensional (3D) T1-weighted magnetic resonance imaging (T1-MRI) and investigated its association with biomarkers. Moreover, the accuracy of semi-automatic measurement of IMH volume was validated. We retrospectively enrolled 33 consecutive patients (mean age 67 ± 11 years) who underwent cardiac MRI after reperfusion therapy for acute myocardial infarction. IMH was observed in 4 patients (12.1%). Receiver operating characteristics (ROC) analysis of creatine kinase (CK) and CK-muscle/brain (CK-MB) tests for detecting IMH were performed. IMH volume measured using semi-automatic methods by a 2 standard deviation (SD) threshold was compared to manual measurements using the Spearman’s correlation coefficient (ρ) and Bland–Altman analyses. ROC analysis revealed optimal cutoff values of CK: 2460 IU/l and CK-MB: 231 IU/l (area under the curve: 0.95 and 0.91; sensitivity: 86% and 79%; specificity: 100% for both). IMH volume with the 2SD threshold correlated with that of the manual measurement [5.84 g (3.30 to 9.00) g vs. 8.07 g (5.37 to 9.33); ρ: 0.85, p < 0.01; bias (limit of agreement): − 0.01 g (− 0.51 to 0.49); intraclass correlation coefficients 0.84 (0.75 to 0.90)]. Our findings could help identify the risk of IMH after reperfusion therapy with biomarkers. 3D T1-MRI can semi-automatically provide accurate IMH volume without being time-consuming.