Small-Signal Stability Analysis and Current Control Reference Optimization Algorithm of DFIG-Based WT During Asymmetric Grid Faults
- 9 December 2020
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 36 (7) , 7750-7768
Abstract
The stability issues of weak grid-connected doubly fed induction generator (DFIG)-based wind turbines (WT) during asymmetric grid faults become very acute. In this paper, a small signal state space model was established to deal with the stability problems of the DFIG system during asymmetric grid faults. Based on the model, the interaction mechanism between the power grid and the DFIG system during asymmetric faults is described and the modal analysis is performed. The analysis results show that the dominant unstable poles of the system are mainly affected by phase locked loop (PLL). Then, according to the vector relationships of voltages and currents, the effect of positive-sequence (PS) and negative-sequence (NS) d-axis currents on the PLL output angle is analyzed. It is pointed out that the system stability can be effectively improved by injecting reasonable d-axis components of PS and NS currents into the power grid during faults. Furthermore, considering the current capacity limitation of DFIG, a novel PS and NS current control reference optimization algorithm is proposed which can suppress the oscillation of the system. Finally, the correctness of theoretical analysis and the effectiveness of proposed control strategy are validated by the simulation and experiments.Keywords
Funding Information
- Joint Research Fund in Smart Grid (U1966208)
- State Grid Corporation of China
- National Natural Science Foundation of China (51977019)
- 111 project of China (B18062)
- State Grid Chongqing Electric Power Company (52202319004G)
This publication has 30 references indexed in Scilit:
- Low-Complexity Model Predictive Direct Power Control for DFIG under both Balanced and Unbalanced Grid ConditionsIEEE Transactions on Industrial Electronics, 2016
- Adaptive Hierarchical Voltage Control of a DFIG-Based Wind Power Plant for a Grid FaultIEEE Transactions on Smart Grid, 2016
- Co-Ordinated Control Strategy for Hybrid Wind Farms With PMSG and FSIG Under Unbalanced Grid Voltage ConditionIEEE Transactions on Sustainable Energy, 2016
- Enhanced Dynamic Voltage Control of Type 4 Wind Turbines During Unbalanced Grid FaultsIEEE Transactions on Energy Conversion, 2015
- Implementation of Fault Ride-Through Techniques of Grid-Connected Inverter for Distributed Energy Resources With Adaptive Low-Pass Notch PLLIEEE Transactions on Power Electronics, 2014
- Stability Analysis of Unbalanced Distribution Systems With Synchronous Machine and DFIG Based Distributed GeneratorsIEEE Transactions on Smart Grid, 2014
- Power controllability of three-phase converter with unbalanced AC source2013
- Long Transmission Lines Fault Location Based on Parameter Identification Using One-Terminal Data2012
- Equivalent models of wind farms by using aggregated wind turbines and equivalent windsEnergy Conversion and Management, 2009
- Dual current control scheme for PWM converter under unbalanced input voltage conditionsIEEE Transactions on Industrial Electronics, 1999