RLRuikuo Liu

Ruikuo Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ruikuo Liu has a total of 31 co-authors. Here are the top co-authors by number of shared publications:

  • Jun Yao

    State Key Laboratory of Power Transmission Equipment Technology, School of Electrical Engineering, Chongqing University, Chongqing, China

    10 shared publications
  • Jinxin Pei

    State Key Laboratory of Power Transmission Equipment and System Security and New Technology, School of Electrical Engineering, Chongqing University, Chongqing, China

    6 shared publications
  • Hailin Zhang

    School of Electrical Engineering Chongqing University Chongqing China

    5 shared publications
  • Jiabing Hu

    Huazhong University of Science and Technology

    3 shared publications
  • Peng Sun

    State Key Laboratory of Power Transmission Equipment and System Security and New Technology, School of Electrical Engineering, Chongqing University, Chongqing, China

    3 shared publications
  • Yuan Liu

    State Key Laboratory of Power Transmission Equipment and System Security and New Technology, School of Electrical Engineering, Chongqing University, Chongqing, China

    3 shared publications

Latest Publications

  • Inertia Evaluation and Optimal Design for PMSG-Based Wind Turbines With df/dt Control

    by Bo Hu, Donghai Zhu, Jiabing Hu, Ruikuo Liu, Xudong Zou, Yong Kang

    The df/dt control is widely used for permanent magnet synchronous generator (PMSG)-based wind turbines (WTs) to achieve inertial response. However, existing studies have only used df/dt control coefficients to characterize the inertia of WTs, which leads to inaccurate inertia evaluation and unsatisfactory design of control parameters. To deal with it, this paper presents an inertia evaluation and optimal design of PMSG-based WTs, by considering the multi-loop control dynamics. Firstly, the magnitude-phase motion model is established and the equivalent inertia in the form of a transfer function is derived. Then, the influence of multi-loop controllers and wind speed on equivalent inertia are explored, and the critical factors are revealed. Further, considering the inertia support requirements and the stable operation of the WTs, the inertia control parameters are optimally designed. Finally, the analysis and design are validated by experiments.


  • Optimized Design of Demagnetization Control for DFIG-Based Wind Turbines to Enhance Transient Stability During Weak Grid Faults

    by Yumei Ma, Donghai Zhu, Jiabing Hu, Ruikuo Liu, Xudong Zou, Yong Kang

    This letter analyzes the transient stability of DFIG-based wind turbines (WTs) with demagnetization control during weak grid faults. It is firstly pointed out that there exist transient instability issues, and the main influential factors (i.e., fault depth, short circuit ratio (SCR), and demagnetization coefficient) on stability have been revealed. On this basis, an optimized design of demagnetization control is firstly proposed for DFIG-based WTs to improve the transient stability during weak grid faults. Finally, the analysis and proposed method are validated by experiments.


  • Transient Stability Analysis and Improved Control Strategy for DC-Link Voltage of DFIG-Based WT During LVRT

    by Shiyue Chen, Jun Yao, Jinxin Pei, Yuan Liu, Ruikuo Liu, Sen Huang, Zhaoyang Chen

    In this paper, the transient stability for dc-link voltage of doubly-fed induction generator (DFIG)-based wind turbine (WT) is studied in detail during low voltage ride-through (LVRT). Firstly, referring to the rotor swing equation of synchronous generator (SG), the nonlinear large-signal model of dc-link voltage is established. In addition, the damping power, static slip power, and dynamic slip power are derived. Consequently, the transient performance of dc-link voltage under the different operation conditions of DFIG is revealed during LVRT. Furthermore, the instability form of dc-link voltage with the moving process of equivalent power angle is analyzed by the energy function of dc-link voltage. In addition, the impacts of dc voltage control loop's parameter, the active current of the stator, and the slip on the stabilization process of dc-link voltage are studied. Analysis result indicates that the insufficient damping and large unbalanced power would deteriorate the transient behavior and steady-state level of dc-link voltage. Therefore, an additional damping and slip power feedforward control strategy is proposed, which can make the transition process of dc-link voltage smoother and significantly improve the voltage steady-state level. Finally, simulation and experimental results validate the effectiveness of theoretical analysis.


  • Small-Signal Stability Analysis and Enhanced Control Strategy for VSC System During Weak-Grid Asymmetric Faults

    by Lei Guan, Jun Yao, Ruikuo Liu, Peng Sun, Siyao Gou

    Small-signal stability issues of the voltage source converters (VSC) connected weak-network during asymmetric faults is currently rarely studied. This paper develops mathematic model of VSC system during weak-grid asymmetric faults, which reveals dynamic coupling between the phase-locked loop (PLL) and both positive-sequence (PS) control system and negative-sequence (NS) control system. Based on the deduced model, the generalized Nyquist criterion (GNC) method and modal analysis are adopted to study the small-signal stability of the VSC system during asymmetric fault steady-state. The analysis demonstrates that the small-signal stability of the system during asymmetric faults is dominated by the PLL mode, and the dynamic coupling between PLL and current control loops (CCLs) will produce negative damping, which will introduce the small-signal instability risk to the system. Moreover, an improved control strategy is designed for enhancing the small-signal stability of the VSC system during weak-grid asymmetric faults, by compensating the disturbance terms related to PLL dynamic to suppress the negative damping introduced by coupling between the PLL and both the PS and NS CCLs. Finally, this paper verifies the effectiveness of the proposed control strategy through simulation and experiment.


  • Small-Signal Stability Analysis and Current Control Reference Optimization Algorithm of DFIG-Based WT During Asymmetric Grid Faults

    by Xin Fang, Jun Yao, Ruikuo Liu, Yang Zhao, Peng Sun, Sen Huang

    The stability issues of weak grid-connected doubly fed induction generator (DFIG)-based wind turbines (WT) during asymmetric grid faults become very acute. In this paper, a small signal state space model was established to deal with the stability problems of the DFIG system during asymmetric grid faults. Based on the model, the interaction mechanism between the power grid and the DFIG system during asymmetric faults is described and the modal analysis is performed. The analysis results show that the dominant unstable poles of the system are mainly affected by phase locked loop (PLL). Then, according to the vector relationships of voltages and currents, the effect of positive-sequence (PS) and negative-sequence (NS) d-axis currents on the PLL output angle is analyzed. It is pointed out that the system stability can be effectively improved by injecting reasonable d-axis components of PS and NS currents into the power grid during faults. Furthermore, considering the current capacity limitation of DFIG, a novel PS and NS current control reference optimization algorithm is proposed which can suppress the oscillation of the system. Finally, the correctness of theoretical analysis and the effectiveness of proposed control strategy are validated by the simulation and experiments.


  • Complex Impedance-Based Frequency Coupling Characteristics Analysis of DFIG-Based WT During Asymmetric Grid Faults

    by Ruikuo Liu, Jun Yao, Peng Sun, Jinxin Pei, Hailin Zhang, Yang Zhao

    In this article, the frequency coupling of weak grid-connected doubly fed induction generator (DFIG) based wind turbines (WT) during asymmetric faults have received little attention. To analyze the frequency coupling phenomenon of the system during asymmetric faults, this article established the complex transfer function model in αβ frame based on the transformation relationship between complex transfer function and transfer matrix. According to the complex transfer function, the frequency coupling mechanism of the DFIG system during asymmetric faults is revealed, and the transfer evolution law of coupling frequencies is described in detail. Finally, the correction of theoretical analysis and the validity of proposed complex transfer models are verified by the simulation and experiment.


  • Virtual Capacitance Control for Improving Dynamic Stability of the DFIG-Based Wind Turbines During a Symmetrical Fault in a Weak AC Grid

    by Peng Sun, Jun Yao, Ruikuo Liu, Jinxin Pei, Hailin Zhang, Yuan Liu

    As the share of wind power in the power system increases, the power grid exhibits the characteristics of a weak grid. The dynamic stability issues of the grid-connected doubly fed induction generator (DFIG)-based wind turbines caused by the interaction between the phase-looked loop (PLL) and rotor current controller (RCC) by high grid impedance have become acute, especially during low-voltage ride-through. In this article, the output impedance model of the DFIG is derived, where the dynamics of the PLL have been first taken into account. In addition, the interaction between the PLL and RCC is analyzed. Furthermore, a novel virtual capacitance control strategy that directly controls the input voltage of the PLL and does not need to change the internal controller parameters and structure is proposed. The proposed control strategy can reduce the effect of the high line impedance by compensating for the PLL output angle deviation. Subsequently, the interaction between the PLL and RCC becomes weaker, and the phase margin of the DFIG system during the severe grid fault increases. Meanwhile, the applicability of the proposed control strategy is presented. Finally, the effectiveness of simulation and experimental results is presented.


  • Characteristic Analysis and Risk Assessment for Voltage–Frequency Coupled Transient Instability of Large-Scale Grid-Connected Renewable Energy Plants During LVRT

    by Jinxin Pei, Jun Yao, Ruikuo Liu, Deyin Zeng, Peng Sun, Hailin Zhang, Yuan Liu

    The voltage-frequency coupled transient stability and risk assessment issues of weak grid-connected large-scale renewable energy plants (REPs) during low voltage ride-through (LVRT) have received little attention to date. The shape and mechanism of voltage-frequency coupled transient instability during LVRT was investigated in detail by the voltage-vector-triangle graphic (VTG) method utilized in this study, which avoids complex mathematical calculations. In addition, the margin of the transmission line's voltage angle (MTVA) was defined in this paper and was then used to quantitatively assess the transient instability risk of the large-scale REPs during LVRT. Furthermore, the expressions of the MTVA were deduced under different conditions and the major influencing factors which resulted in instability risk were determined correspondingly. On this basis, the transient instability risk assessment standard of the large-scale REPs is built and the instability risk minimized scheduling strategy is proposed in this paper, which does not change the internal control structure and parameters of the REPs during LVRT. Finally, both the correctness of the VTG method and the risk assessment standard, and the effectiveness of the scheduling strategy proposed in this paper are validated by experiments and simulations.


  • Analysis and Damping Control of Small-Signal Oscillations for VSC Connected to Weak AC Grid During LVRT

    by Xuewei Wang, Jun Yao, Jinxin Pei, Peng Sun, Hailin Zhang, Ruikuo Liu

    The instability issues of grid-connected voltage source converters (VSC) may easily occur during low voltage ride-through (LVRT), especially when connected to a weak AC grid. In this study, a small-signal model of the grid-connected VSC system was developed to deal with the stability problems during deep voltage sags. Based on the model, the interaction between the phase-locked loop (PLL) and current control has been illustrated. In addition, the eigenvalue and modal analysis method was employed to investigate the influencing factors of the VSC system stability, which include the bandwidths of the PLL and current control loop, grid strength, and voltage sags. Furthermore, on the basis of the interaction between PLL and current control loop, a novel additional damping controller which is placed in the active current control loop was proposed and designed. Finally, experiments were conducted to verify the theoretical analysis and proposed control strategy for enhancing VSC system stability during LVRT with a high impedance grid connection.


  • Dynamic Stability Analysis and Improved LVRT Schemes of DFIG-Based Wind Turbines During a Symmetrical Fault in a Weak Grid

    by Ruikuo Liu, Jun Yao, Xuewei Wang, Peng Sun, Jinxin Pei, Jiabing Hu

    With the increasing penetration of the wind power, the stability issues of the weak AC grid-connected doubly fed induction generator (DFIG)-based wind turbines during low voltage ride through (LVRT) cannot be neglected. In order to explore the instability mechanism of DFIG system during weak grid fault, the small signal state space model is established in this paper. The results of the modal analysis show that the dominant unstable poles are mainly impacted by the phase locked loop (PLL), rotor current control loop (RCCL) and terminal voltage during the fault, where the PLL is the dominant factor. Furthermore, the impact of each factors on the system dynamic stability are comprehensively evaluated, which indicates that the controller bandwidth under normal grid condition is no longer apply to the fault condition due to the interaction between the controller and grid. Then, the optimal current proportion which can significantly improve the system stability is deduced. Finally, based on the analysis, this paper proposes the improved LVRT control schemes from two aspects of either injecting active current or decreasing PLL bandwidth to enhance the system small signal stability. The effectiveness of the proposed LVRT control strategies is validated by the simulation and experiments.