Quantification of left ventricular function and mass in cardiac Dual-Source CT (DSCT) exams: comparison of manual and semiautomatic segmentation algorithms
- 22 February 2008
- journal article
- research article
- Published by Springer Nature in European Radiology
- Vol. 18 (5) , 939-946
Abstract
The purpose of our study was to evaluate reliability of left ventricular (LV) function and mass quantification in cardiac DSCT exams comparing manual contour tracing and a region-growing-based semiautomatic segmentation analysis software. Thirty-three consecutive patients who underwent cardiac DSCT exams were included. Axial 1-mm slices were used for the semiautomated technique, and short-axis 8-mm slice thickness multiphase image reconstructions were the basis for manual contour tracing. Left ventricular volumes, ejection fraction and myocardial mass were assessed by both segmentation methods. Length of time needed for both techniques was also recorded. Left ventricular functional parameters derived from semiautomatic contour detection algorithm were not statistically different from manual tracing and showed an excellent correlation (p<0.001). The semiautomatic contour detection algorithm overestimated LV mass (180.30±44.74 g) compared with manual contour tracing (156.07±46.29 g) (p<0.001). This software allowed a significant reduction of the time needed for global LV assessment (mean 174.16±71.53 s, p<0.001). Objective quantification of LV function using the evaluated region-growing-based semiautomatic segmentation analysis software is feasible, accurate, reliable and time-effective. However, further improvements are needed to equal results achieved by manual contour tracing, especially with regard to LV mass quantification.Keywords
This publication has 51 references indexed in Scilit:
- Dual-Source Computed Tomography for Assessing Cardiac FunctionInvestigative Radiology, 2007
- Coronary Angiography by 64-Detector Row Computed Tomography Using Low Dose of Contrast Material with Saline ChaserJournal of Computer Assisted Tomography, 2007
- Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate controlEuropean Radiology, 2006
- Cardiovascular Function in Multi-Ethnic Study of Atherosclerosis: Normal Values by Age, Sex, and EthnicityAmerican Journal of Roentgenology, 2006
- Helical cardiac cone beam CT reconstruction with large area detectors: a simulation studyPhysics in Medicine & Biology, 2005
- Assessment of Left Ventricular Parameters Using 16-MDCT and New Software for Endocardial and Epicardial Border DelineationAmerican Journal of Roentgenology, 2005
- Time-effectiveness, Observer-dependence, and Accuracy of Measurements of Left Ventricular Ejection Fraction Using 4-channel MDCTRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2004
- Räumliche und zeitliche Auflösung für die Herzdiagnostik mit 16-Schicht-ComputertomographieRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2003
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Variables predictive of survival in patients with coronary disease. Selection by univariate and multivariate analyses from the clinical, electrocardiographic, exercise, arteriographic, and quantitative angiographic evaluations.Circulation, 1979