Experimental Evaluation on Low Global Warming Potential HFO-1336mzz-Z as an Alternative to HCFC-123 and HFC-245fa
- 29 January 2019
- journal article
- research article
- Published by ASME International in Journal of Thermal Science and Engineering Applications
- Vol. 11 (3)
Abstract
HFO-1336mzz-Z with low global warming potential (GWP) was considered as a promising alternative of HCFC-123, HFC-245fa in air conditioning (AC) and heat pump (HP), respectively. In order to understand the operation performances of HFO-1336mzz-Z and HCFC-123, HFC-245fa in different working conditions, an experimental setup for testing the refrigeration cycle performance was built. The cycle performances of HFO-1336mzz-Z and HCFC-123 in AC conditions, HFO-1336mzz-Z and HFC-245fa in HP conditions were investigated by experiment. It was found in AC conditions, the discharge temperatures for the systems with HFO-1336mzz-Z and HCFC-123 were lower than 115 °C, the cooling capacity of the system with HFO-1336mzz-Z was 27% less than that with HCFC-123 at least, and the coefficient of performance (COP) of the system with HFO-1336mzz-Z was 0.1 lower than that with HCFC-123; in HP conditions, the discharge temperature with HFO-1336mzz-Z was lower than that with HFC-245fa, the former was never over 115 °C while the latter was up to 126 °C, the power input to the compressor with HFO-1336mzz-Z was 20% less than that with HFC-245fa in the same HP conditions, the heating capacity of the system with HFO-1336mzz-Z was 30–40% less than that with HFC-245fa.Keywords
Funding Information
- National Natural Science Foundation of China (51376159)
- Science and Technology Department of Zhejiang Province (2016F50053)
- Hong Kong Polytechnic University (G-SB76)
This publication has 18 references indexed in Scilit:
- Low GWP refrigerants R1234ze(E) and R1234ze(Z) for high temperature heat pumpsInternational Journal of Refrigeration, 2014
- Sustainability with prospective refrigerantsInternational Journal of Energy Research, 2013
- Cycle performance studies on HFC-161 in a small-scale refrigeration system as an alternative refrigerant to HFC-410AEnergy and Buildings, 2012
- The refrigerant R1234yf in air conditioning systemsEnergy, 2011
- Atmospheric Chemistry of (Z)-CF3CH═CHCF3: OH Radical Reaction Rate Coefficient and Global Warming PotentialThe Journal of Physical Chemistry A, 2011
- The fluorinated olefin R-1234ze(Z) as a high-temperature heat pumping refrigerantInternational Journal of Refrigeration, 2009
- Evolving an optimal composition of HFC407C/HC290/HC600a mixture as an alternative to HCFC22 in window air conditionersInternational Journal of Thermal Sciences, 2007
- Experimental study on HFC-161 mixture as an alternative refrigerant to R502International Journal of Refrigeration, 2005
- Options and outlook for chiller refrigerantsInternational Journal of Refrigeration, 2002
- Large losses of total ozone in Antarctica reveal seasonal ClOx/NOx interactionNature, 1985