Effects of Dynamic Compression Plate (DCP) and Limited Contact Dynamic Compression Plate (LC-DCP) on Resistance of Radius against Axial Compression: Biomechanical Investigation
Open Access
- 26 August 2025
- journal article
- Published by KTO Karatay University in KTO Karatay Üniversitesi Sağlık Bilimleri Dergisi
- Vol. 6 (2) , 254-264
Abstract
Objective: Dynamic compression plate (DCP) and limited contact dynamic compression plate (LC- DCP) are used for open reduction internal fixation of radial shaft fractures. They are distinguished from other systems by the principles of reduced plate-bone contact and dynamic compression. This study aims to compare the stress and deformation under axial forces in DCP and LC-DCP. Materials and Methods: The DCP and LC-DCP were applied to 16 artificial radius bones by an experienced surgeon fixed at the distal and proximal of the fracture line with three cortical screws for each. In axial loading tests, the amount of force applied to the sawbones with DCP and LC-DCP and the amount of extension were calculated. Results: DCP and LCDCP fixation plates on forearm fracture models were found to be statistically similar in terms of the applied force and displacement (p=0.161). Conclusion: The study showed both implant types (DCP and LC-DCP) could be appropriate for the fixation of forearm fractures and osteotomies due to no mechanically significant difference under axial loadings. The plate to be applied can definitely be chosen considering the cost of the plate and the anatomical requirements.Keywords
This publication has 33 references indexed in Scilit:
- Evolution of fracture treatment with bone platesInjury, 2018
- Evaluation of Bone Atrophy After Treatment of Forearm Fracture Using Nonlinear Finite Element Analysis: A Comparative Study of Locking Plates and Conventional PlatesThe Journal of Hand Surgery, 2017
- Pre- and postoperative complications of adult forearm fractures treated with plate fixationOrthopaedics & Traumatology: Surgery & Research, 2016
- Optimizing compression: Comparing eccentric plate holes and external tensioning devicesInjury, 2016
- The dynamisation of locking plate osteosynthesis by means of dynamic locking screws (DLS)—An experimental study in sheepInjury, 2013
- The dynamic locking screw (DLS) can increase interfragmentary motion on the near cortex of locked plating constructs by reducing the axial stiffnessLangenbeck's Archives of Surgery, 2010
- Comparison of interface contact profiles of a new minimum contact locking compression plate and the limited contact dynamic compression plateInternational Orthopaedics, 2009
- The initial phase of fracture healing is specifically sensitive to mechanical conditionsJournal of Orthopaedic Research, 2003
- Internal fixation of forearm fractures in the 1980s: lessons to be learntInjury, 1991
- The concept of biological plating using the limited contact — dynamic compression plate (LC-DCP)Injury, 1991