RHResit Bugra Husemoglu

Resit Bugra Husemoglu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Resit Bugra Husemoglu has a total of 78 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Labral Graft Volume Augmentation and Femoral Remplissage Have Positive Impact on Hip Distraction Stability After Excessive Cam Resection: An Ovine Model

    by Resit Bugra Husemoglu, Selahaddin Aydemir, Eren Akın, Çağrı Havıtçıoğlu, Mithat İbOlar, Onur Hapa, Hasan Havıtçıoğlu

    Purpose: To biomechanically assess the effects of femoral remplissage and labral volume augmentation, individually and in combination, on restoring hip distraction stability after excessive cam resection in an ovine model. Methods: Forty‐eight fresh‐frozen ovine hips were randomized into 6 groups (n = 8): (1) remplissage, (2) baseline labral reconstruction, (3) combined baseline reconstruction, (4) increased thickness (2×), (5) combined augmented (2× + remplissage), and (6) excessive thickness (4×). A 10% over‐resection defect was created at the anterosuperior head‐neck junction. Autologous tendon grafts were fixed with 2.0 mm titanium anchors. Distraction testing at 90° flexion was performed under a 200 N load at 60 mm/min. Suction seal strength was defined as the peak resistance force (N) during femoral head separation. Two parameters were calculated: Δ 1 (Postop‐Intact) for residual loss and Δ 2 (Postop‐Excised) for stability recovery. Statistical analysis used Kruskal‐Wallis and Bonferroni‐corrected Mann‐Whitney U tests ( P < .003). Results: Excessive cam resection significantly reduced suction seal strength ( P < .001). The 4× reconstruction and 2× + remplissage groups achieved the best stability restoration (4×: Δ 1 = 0.78 N, Δ 2 = 24.06 N; 2× + remplissage: Δ 1 = 4.53 N, Δ 2 = 23.12 N; both P < .003 vs baseline). Remplissage alone provided partial recovery, whereas baseline reconstruction had the weakest performance (Δ 1 = 11.48 N, Δ 2 = 14.92 N). Increasing graft thickness improved both Δ 1 and Δ 2 , correlating with greater stability recovery. Conclusions: Standard labral reconstruction alone did not fully restore suction seal strength after excessive cam resection. Increasing graft volume improved distractive stability compared with the resected state, and combined 2× labral augmentation with femoral remplissage achieved stability restoration comparable to the 4× reconstruction group. Remplissage alone provided partial recovery but did not consistently restore intact‐level stability. Clinical Relevance: These findings suggest that increased graft thickness and femoral remplissage may improve distractive stability in an ex vivo over‐resection model.

  • Length of the fractured level screw has no significant effect on biomechanical stability in short-segment thoracolumbar fixation—in vitro biomechanical study in a sheep model

    by Selahaddin Aydemir, Anıl Murat Öztürk, Ahmet Karakaşlı, Reşit Buğra Hüsemoğlu, Mustafa Çeltik, Onur Süer, Ömer Akçalı

    Objective: While pedicle screw placement at the fracture level improves stability in short-segment posterior instrumentation for thoracolumbar fractures, the optimal screw length remains controversial. The biomechanical effect of screw length at the fracture level has not been clearly defined under controlled conditions. This study compared short (≤50% vertebral body length) and long (≥70%) screws in a sheep burst fracture model. Methods: Twenty-one fresh sheep thoracolumbar spines with experimentally induced L1 burst fractures (AO Type A4) were randomly divided into 3 groups: Group 1 (no fracture-level screw), Group 2 (short screws: ≤ 50% of the vertebral body length [20 mm]), and Group 3 (long screws: ≥ 70% of the body length [35 mm]). All specimens were instrumented with pedicle screw constructs. Stability was assessed under axial compression, flexion–extension, lateral bending, and axial rotation using a Shimadzu AG-X testing machine (Kyoto, Japan). Axial displacement was recorded to derive range of motion (ROM) as a primary indicator of construct stability. Post-hoc power analysis revealed 58% power to detect a 0.5 mm displacement difference; therefore, results are interpreted as “no statistically significant difference” rather than equivalence. Results: Incorporating a fracture-level screw significantly improved stability vs. Group 1 (P < .01). No significant differences were observed between short and long screws in axial compression ROM (0.91 ± 0.19 mm vs. 0.89 ± 0.26 mm, P = .87), flexion/extension ROM (1.41 ± 0.20 mm [3.2° ± 0.5°] vs. 1.17 ± 0.24 mm [2.7° ± 0.6°], P = .12), lateral bending ROM (1.27 ± 0.31 mm [2.9° ± 0.7°] vs. 0.88 ± 0.11 mm [2.0° ± 0.3°], P = .09), or axial rotation failure displacement (80.44 ± 41.31 mm vs. 71.44 ± 29.51 mm, P = .23). Fragment displacement was significantly greater in the long-screw group (3.51 ± 1.25 mm) than in the short-screw group (0.00 ± 0.00 mm, P < .001). Conclusion: Within the limitations of this sheep model and with only 58% power to detect a 0.5 mm difference, short screws (≤50% vertebral body length) demonstrated no statistically significant difference in biomechanical stability compared to long screws (≥70%) in short segment posterior fixation under the tested conditions. However, long screws were associated with significant anterior fragment displacement, a potentially clinically relevant finding requiring further computed tomography (CT)-based validation. These findings suggest a potential advantage of short screws in avoiding anterior fragment displacement without compromising biomechanical stability. However, given the study’s power limitations and the absence of CT-based fragment displacement validation, these results are preliminary. Clinical recommendations require confirmation in adequately powered human studies with formal equivalence testing and post-instrumentation CT imaging. Cite this article as: Aydemir S, Ozturk AM, Karakasli A, et al. Length of the fractured level screw has no significant effect on biomechanical stability in shortsegment thoracolumbar fixation—in vitro biomechanical study in a sheep model. Acta Orthop Traumatol Turc., 2026; 60(5), 01021, doi: 10.5152/j.aott.2026.261021.

  • Open Access

    Evaluation of a novel strap fixation method for biomechanical testing of sheep Achilles tendons

    by Onur Basci, Selahaddin Aydemir, Resit Bugra Husemoglu, Mustafa Çeltik

    Reliable fixation of tendon specimens is a major challenge in biomechanical testing, as slippage and tissue damage can reduce accuracy and reproducibility. Although various clamp- and suture-based fixation methods have been reported, there is still no widely accepted, practical, low-cost technique that preserves tendon integrity during testing. This study aimed to compare commonly used fixation techniques and to evaluate whether a novel strap-based fixation method provides a more stable and tissue-preserving alternative for biomechanical testing of sheep Achilles tendons. Forty fresh-frozen cadaveric sheep Achilles tendons obtained from a local butcher were used, and the specimens were stored at - 20 °C until testing. After controlled thawing at room temperature, all tendons were repaired using the Bunnell suture technique with No. 0 Vicryl. Four different proximal fixation methods were evaluated: (1) sutured fixation with strap, (2) direct clamp fixation, (3) Kocher clamp fixation, and (4) Krackow suture fixation. All specimens were mounted on a universal testing machine and subjected to a load-to-failure protocol at a constant loading rate of 10 mm/s. Maximum force (N), displacement at failure (mm), and mechanical failure mechanisms were recorded for each sample. Data were analyzed using the Kruskal-Wallis test with Bonferroni-corrected Mann-Whitney U tests for pairwise comparisons (p < 0.0083). The strap method demonstrated the highest numerical load-carrying capacity [114.58 N (73.59-135.00)] with relatively controlled displacement [16.96 mm (8.79-26.52)]. Its maximum load was significantly higher than that of the direct clamp and Kocher clamp methods; however, the difference compared with the Krackow suture method did not remain statistically significant after Bonferroni correction. Tendons fixed directly by clamp (Group 2) exhibited tissue damage due to clamp pressure and showed lower load capacity [75.41 N (58.28-110.78)] with greater displacement [28.01 mm (17.63-51.93)]. The Kocher clamp method (Group 3) provided the lowest mechanical strength, and most specimens slipped at the onset of loading [38.35 N (26.41-49.53); 15.55 mm (10.92-17.54)]. The Krackow suture method (Group 4) showed intermediate performance [82.95 N (65.62-148.50); 27.00 mm (19.49-30.75)]. The strap fixation method provided stable fixation, no visible slippage, and the highest numerical load-to-failure values among the tested techniques. It was significantly stronger than the direct clamp and Kocher clamp methods; however, it was not statistically superior to the Krackow suture method after Bonferroni correction. The strap method may therefore be considered a practical and tissue-preserving alternative for further biomechanical tendon testing.

  • Open Access

    Clinical and Radiological Outcomes of C1–C2 Fixation: 3D-Printed Template vs. Free-Hand Technique

    by Ceren Kizmazoglu, Koray Ur, Inan Uzunoglu, Bugra Husemoglu, Ersin Ikizoglu, Musa Sezer, Ege Coskun, Mert Arslan, Hatun Mine Sahin, Ercan Ozer

    Objectives: The Goel–Harms technique provides rapid stabilization and high fusion rates for atlantoaxial instability but carries a risk of neurovascular injury during lateral mass and pedicle screw insertion. Recently, 3D printing has emerged as a cost-effective and increasingly accessible tool in various surgical fields. This study aimed to compare the clinical and radiological outcomes of C1–C2 fixation using a 3D-printed template versus the free-hand technique. Methods: This retrospective cohort study included patients who underwent C1–C2 fixation with the Goel–Harms technique at two tertiary neurosurgical centers between 2021 and 2023. Operative, radiological, and functional outcomes were reviewed in 21 patients who were operated using either a patient-specific 3D-printed template applied intraoperatively (Group 1; n = 10) or the free-hand technique (Group 2; n = 11). Postoperative screw accuracy was assessed using the Gertzbein–Robbins classification. Results: A total of 84 screws were placed (Group 1: 40; Group 2: 44). In Group 1, 38 of 40 screws (95%) were accurately placed, compared with 41 of 44 screws (93.1%) in Group 2. The mean fluoroscopy and operative times were significantly shorter in Group 1 than in Group 2 (21.90 ± 4.33 s vs. 27.09 ± 13.48 s, p = 0.012; 126.60 ± 28.70 min vs. 171.36 ± 40.44 min, p = 0.010, respectively). Conclusions: The 3D-printed template technique significantly reduced operative and fluoroscopy times compared with the free-hand technique. Three-dimensional printing offers a cost-effective alternative to conventional navigation systems by eliminating their time-consuming preoperative setup in the operating room.


  • Exploring Various Labral Reconstruction Techniques in an Ovine Hip Model: A Biomechanical Perspective

    by Selahaddin Aydemir, Cagri Havitcioglu, Eren Akin, Mustafa Celtik, Firat Aydin, R. Bugra Husemoglu, Onur Hapa

    Background: Labral reconstruction using various graft materials, including autografts and allografts, is gaining popularity to address labral deficiencies. However, the biomechanical effects of graft size, type, and fixation techniques remain underexplored. Purpose/Hypothesis: The purpose was to evaluate the effects of graft size, graft type, tubularization, and anchor number on suction seal force and distractive stability in an ovine hip model. It was hypothesized that larger graft sizes and the use of allografts would improve the suction seal force and distractive stability compared with smaller grafts and fewer anchor numbers, while tubularization would have no significant effect. Study Design: Controlled laboratory study. Methods: A total of 40 sheep hip joints were randomly assigned to 5 groups. Labral excision was performed, followed by reconstruction using autografts or allografts. Ovine extensor tendons were chosen as autografts, whereas labrums from a different ovine hip were used for allografts. For group 1, autografts matching the original labral width were used. For group 2, autografts twice the original labral width were used. For group 3, allografts matching the original labral width were harvested from a different ovine hip. For group 4, autografts matching the original width were fixed with only 2 anchors. For group 5, autografts matching the original width were tubularized before use. Suction seal force was measured before and after reconstruction using an electromechanical testing system. Statistical analyses included Mann-Whitney U and Wilcoxon signed-rank tests ( P < .05). Results: Group 2 showed the highest improvement in suction seal force, outperforming all other groups ( P < .01). Group 4 exhibited the lowest distractive stability among all groups. Tubularization (group 5) did not enhance biomechanical performance ( P = .752). Group 3, reconstructed with an allograft, exhibited suction seal performance most closely approximating that of group 2, with no significant difference between them. Conclusion: The data from the ovine cadaveric model indicate that increasing the graft size enhances the suction sealing force; however, it remains below the measurements observed in an intact labrum. Furthermore, increasing the number of anchors and optimal graft selection improve postoperative biomechanical stability. Clinical Relevance: Optimizing graft size and fixation techniques in labral reconstruction may improve joint stability and suction seal function and may support surgical strategies aimed at improving outcomes and delaying the progression of osteoarthritis in patients with labral defects.


  • Open Access

    Effects of Dynamic Compression Plate (DCP) and Limited Contact Dynamic Compression Plate (LC-DCP) on Resistance of Radius against Axial Compression: Biomechanical Investigation

    by Ferhat Sayar, Hasan Havıtçıoğlu, R. Bugra Husemoglu, Yunus Emre Bektaş, Ortaç Güran, Ali İhSan Kılıç

    Objective: Dynamic compression plate (DCP) and limited contact dynamic compression plate (LC- DCP) are used for open reduction internal fixation of radial shaft fractures. They are distinguished from other systems by the principles of reduced plate-bone contact and dynamic compression. This study aims to compare the stress and deformation under axial forces in DCP and LC-DCP. Materials and Methods: The DCP and LC-DCP were applied to 16 artificial radius bones by an experienced surgeon fixed at the distal and proximal of the fracture line with three cortical screws for each. In axial loading tests, the amount of force applied to the sawbones with DCP and LC-DCP and the amount of extension were calculated. Results: DCP and LCDCP fixation plates on forearm fracture models were found to be statistically similar in terms of the applied force and displacement (p=0.161). Conclusion: The study showed both implant types (DCP and LC-DCP) could be appropriate for the fixation of forearm fractures and osteotomies due to no mechanically significant difference under axial loadings. The plate to be applied can definitely be chosen considering the cost of the plate and the anatomical requirements.

  • Open Access

    Comparative effects of hip capsule repair and cam lesion excision on capsulotomy healing: An in vivo biomechanical and histological analysis

    by Abbas Aghayev, Burak Duymaz, Selahaddin Aydemir, Pınar Akokay Yılmaz, Gurhan Tukel, Resit Bugra Husemoglu, Onur Gürsan, Onur Hapa

    Purpose: This study evaluates the effects of hip capsule repair and cam lesion excision on capsular healing by assessing biomechanical strength and histological integrity in an in vivo rabbit model.Methods: An in vivo rabbit model with 80 rabbits was used, where capsulotomy was performed on the right hip of each subject. The rabbits were assigned into four groups: Group 1 (capsulotomy without repair), Group 2 (capsulotomy with capsule repair), Group 3 (capsulotomy + cam resection without repair), Group 4 (capsulotomy + cam resection + capsule repair). Each group was stratified into 4‐week and 8‐week follow‐up subgroups. Biomechanical testing assessed maximum tensile strength, while histological evaluation included semiquantitative grading of collagen arrangement, inflammatory response, osteogenesis, and angiogenesis.Results: Histological analysis revealed superior healing in the capsule repair + cam resection group (Group 4) compared to the unrepaired capsulotomy group (Group 1) (p = 0.01). Biomechanical testing demonstrated that capsule repair (Group 2) improved strength over unrepaired capsulotomy (135.2 N vs. 111.9 N, p = 0.03). Cam resection alone (Group 3) resulted in significantly higher strength than unrepaired capsulotomy (163.2 N vs. 111.9 N, p = 0.01). The combination of cam resection and capsule repair (Group 4) demonstrated superior strength, outperforming capsule repair alone (176 N vs. 135.2 N, p = 0.01). At 8 weeks, the capsule repair + cam resection group (Group 4a) showed significantly enhanced biomechanical strength compared to the unrepaired capsulotomy group (Group 1a) (181.6 N vs. 120.9 N, p = 0.001) and capsule repair alone (Group 2a) (181.6 N vs. 125.8 N, p = 0.01).Conclusion: Our findings indicate that cam resection, particularly when combined with capsule repair, significantly improves biomechanical strength and enhances the healing process of the capsule. These findings offer practical guidance for optimising surgical strategies to enhance patient outcomes and long‐term joint function.Level of Evidence: Level III, experimental therapeutic study (prospective and controlled).


  • Open Access

    Comparison of tendon healing using local platelet-rich plasma, erythropoietin, and erythropoietin-bevacizumab in a rat achilles tenotomy model

    by Ahmet Emrah Açan, Aslı Karakılıç, Mert Emre Aydın, Özgür Bulmuş, Emrah Özcan, Gülay Turan, Özge Özmen, Reşit Buğra Hüsemoğlu

    Joint Diseases and Related Surgery (JDRS), the official journal of the Turkish Joint Diseases Foundation, is an international, peer-reviewed, immediate open access journal. All published articles in JDRS has been free for everyone, without embargo, since 1990.


  • Open Access

    Irisin and its role in fracture healing: A comparative study with hyaluronic acid and platelet-rich plasma in a rat model

    by Ahmet Emrah Açan, Mert Emre Aydın, Özgür Bulmuş, Emrah Özcan, Aslı Karakılıç, Gülay Turan, Reşit Buğra Hüsemoğlu

    Joint Diseases and Related Surgery (JDRS), the official journal of the Turkish Joint Diseases Foundation, is an international, peer-reviewed, immediate open access journal. All published articles in JDRS has been free for everyone, without embargo, since 1990.


  • Open Access

    The effects of gabapentin and pregabalin on fracture healing: A histological, radiological, and biomechanical analysis

    by Ahmet Emrah Açan, Mert Emre Aydın, Özgür Bulmuş, Emrah Özcan, Aslı Karakılıç, Gülay Turan, Reşit Buğra Hüsemoğlu

    Joint Diseases and Related Surgery (JDRS), the official journal of the Turkish Joint Diseases Foundation, is an international, peer-reviewed, immediate open access journal. All published articles in JDRS has been free for everyone, without embargo, since 1990.