Safe procedures despite ultra low radiation doses during catheter ablations of atrial and ventricular arrhythmias—A multicenter experience
Open Access
- 5 March 2021
- journal article
- research article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 44 (5) , 807-813
Abstract
Introduction: Despite the development of non‐fluoroscopic catheter visualization options, fluoroscopy is still used in most ablation procedures. The aim of this multicenter study was to evaluate the safety and efficacy of a new ultra‐low dose radiation protocol for EP procedures in a large number of patients.Methods and results: A total of 3462 consecutive patients (male 1926 (55.6%), age 64.4 ± 14.0 years, BMI 26.65 ± 4.70) undergoing radiofrequency ablation (left atrial (n = 2316 [66.9%], right atrial (n = 675 [19.5%], or ventricular (n = 471 [13.6%]) in three German centers were included in the analysis. Procedures were performed using a new ultra‐low dose protocol operating at 8nGy for fluoroscopy and 36nGy for cine‐loops. Additionally a very low framerate (2‐3FPS) was used. Using the new protocol very low Air kerma‐area product (KAP) values were achieved for left atrial ablations (104.25 ± 84.22 μGym2), right atrial ablations (70.98 ± 94.79 μGym2) and ablations for ventricular tachycardias or PVCs (78.62 ± 66.59 μGym2). Acute procedural success was achieved in 3289/3388 (97.1%) while the rate of major complications was very low compared to previously published studies not using low dose settings (n = 20, 0.6%).Conclusion: The ultra‐low dose, low framerate protocol leads to very low radiation doses for all EP procedures while neither procedural time, fluoroscopy time nor success or complication rates were compromised. When compared to current real‐world Air KAP data the new ultra‐low dose fluoroscopy protocol reduces radiation exposure by more than 90%.Keywords
This publication has 14 references indexed in Scilit:
- Reducing radiation exposure during procedures performed in the electrophysiology laboratoryJournal of Cardiovascular Electrophysiology, 2017
- Evaluation of automatic dose rate control for flat panel imaging using a spatial frequency domain figure of meritPhysics in Medicine & Biology, 2017
- Pushing the limits: establishing an ultra-low framerate and antiscatter grid-less radiation protocol for left atrial ablationsEP Europace, 2017
- Important reduction of the radiation dose for pulmonary vein isolation using a multimodal approachEP Europace, 2016
- Development of radiation exposure in patients undergoing pulmonary vein isolation in Germany between 2007 and 2014: great potential to minimize radiation dosageClinical Research in Cardiology, 2016
- Evaluation of a new very low dose imaging protocol: feasibility and impact on X-ray dose levels in electrophysiology proceduresEP Europace, 2015
- Use of fluoroscopy in clinical electrophysiology in Europe: results of the European Heart Rhythm Association SurveyEP Europace, 2015
- Brain and Neck Tumors Among Physicians Performing Interventional ProceduresThe American Journal of Cardiology, 2013
- The occupational effects of interventional cardiology: results from the WIN for Safety surveyEuroIntervention, 2012
- Updated Worldwide Survey on the Methods, Efficacy, and Safety of Catheter Ablation for Human Atrial FibrillationCirculation: Arrhythmia and Electrophysiology, 2010