Design and Performance Test of Pulse X-Ray Receiver Based on LYSO-SiPM for X-Ray Communication
- 25 March 2022
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 40 (13) , 4217-4223
Abstract
X-ray communication (XCOM) is a type of wireless optical communication technology that uses modulated X-ray beam as the carrier of data transmission. As a core component of an XCOM system, the X-ray signal receiver determines the upper limit of the communication rate and the quality of communication. A pulse X-ray signal receiver based on an LYSO-SiPM detector and a field-programmable gate array signal processing module is designed to solve the problems of considerable background noise and weak signal strength in the actual XCOM process. The low bit error rate (BER) at the Mbps rate is realized first for XCOM. An XCOM performance test system is used to test the receiver's signal output characteristics and communication performance. The communication rate reaches 1.21 Mbps with BER less than 1.0 × 10 −5 . The designed pulse X-ray signal receiver can effectively identify X-ray pulse under high bandwidth and weak signal receiving power.Keywords
Funding Information
- Chinese Aeronautical Establishment (2018ZC52029)
This publication has 15 references indexed in Scilit:
- Potential application of X-ray communication in Martian dust stormActa Astronautica, 2020
- Power budget and performance analysis of X-ray communication during the Earth re-entry of spacecraftOptik, 2019
- Understanding the intrinsic radioactivity energy spectrum from 176Lu in LYSO/LSO scintillation crystalsScientific Reports, 2018
- Would Scaling to Extreme Ultraviolet or Soft X-Ray Communications Resolve the Capacity Crunch?Journal of Lightwave Technology, 2018
- Transmission properties and physical mechanisms of X-ray communication for blackout mitigation during spacecraft reentryPhysics of Plasmas, 2017
- The Test and Analysis on Pulse Signal Detection Abilities of the X-ray Detector MCP for Pulsar NavigationLecture Notes in Electrical Engineering, 2017
- Potential application of X-ray communication through a plasma sheath encountered during spacecraft reentry into earth's atmosphereJournal of Applied Physics, 2017
- NICER instrument detector subsystem: description and performance2016
- Next Generation of Space Wireless Communication Technology Based on X-rayACTA PHOTONICA SINICA, 2013
- Quality of a 28 cm Long LYSO Crystal and Progress on Optical and Scintillation PropertiesIEEE Transactions on Nuclear Science, 2012