Junxu Mu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Junxu Mu has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Xiaobin Tang
Nanjing University of Aeronautics and Astronautics
4 shared publications - Yunpeng Liu
Department of Nuclear Science and Technology, Nanjing University of Aeronautics and Astronautics, Nanjing, China
4 shared publications Sheng Lai
Nanjing Univ Aeronaut & Astronaut, Dept Nucl Sci & Technol, Nanjing 210016, Peoples R China
2 shared publications- Ao Xia
Department of Nuclear Science and Technology, Nanjing University of Aeronautics and Astronautics, Nanjing, China
1 shared publication Feixu Xiong
Nanjing Univ Aeronaut & Astronaut, Dept Nucl Sci & Technol, Nanjing 210016, Peoples R China
1 shared publication- Hao Yu
Department of Nuclear Science and Technology, Nanjing University of Aeronautics and Astronautics, Nanjing, China
1 shared publication
Latest Publications
- 1 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 71 (11) , 7099-7105
Design and Testing of Metal Photocathode X-Ray Source Based on Microchannel Plate
This work developed a microchannel plate-based metal photocathode X-ray source (MCP-MPXS). The MCP-MPXS structure was optimized using the non-dominated sorting genetic algorithm (NSGA)-II algorithm. A prototype was then built based on the optimization results, and the current characteristics, X-ray pulse properties, and X-ray imaging performance of the MCP-MPXS were investigated using a dynamic vacuum system. The MCP-MPXS achieved a current gain exceeding $10^{{4}}$ and had not yet reached its performance limit. With an X-ray pulse modulation frequency (MF) exceeding 10 MHz, the MCP-MPXS outperformed current grid-controlled modulated and most photocathode X-ray sources (PXSs). Modulation rates of several tens of megahertz can be achieved by refining the LED drive circuit. Furthermore, the MCP-MPXS obtained the best focal spot with a focusing ring voltage of 2000 V, which was consistent with the simulation results and verified the effectiveness of the optimization algorithm. The optimal focal spot is $0.53\times 0.79$ mm with an imaging resolution of up to 3.9 lp/mm. The system is also capable of dynamic imaging with X-ray pulse widths as short as $50~\mu $ s. Results show that the developed MCP-MPXS solves the problem of insufficient output intensity of traditional MPXSs, realizes high-speed X-ray modulation, and is capable of high-resolution X-ray imaging. This X-ray source has broad application prospects in X-ray communication and high-speed X-ray imaging.
- 1 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 71 (11) , 7099-7105
Design and Testing of Metal Photocathode X-Ray Source Based on Microchannel Plate
This work developed a microchannel plate-based metal photocathode X-ray source (MCP-MPXS). The MCP-MPXS structure was optimized using the non-dominated sorting genetic algorithm (NSGA)-II algorithm. A prototype was then built based on the optimization results, and the current characteristics, X-ray pulse properties, and X-ray imaging performance of the MCP-MPXS were investigated using a dynamic vacuum system. The MCP-MPXS achieved a current gain exceeding $10^{{4}}$ and had not yet reached its performance limit. With an X-ray pulse modulation frequency (MF) exceeding 10 MHz, the MCP-MPXS outperformed current grid-controlled modulated and most photocathode X-ray sources (PXSs). Modulation rates of several tens of megahertz can be achieved by refining the LED drive circuit. Furthermore, the MCP-MPXS obtained the best focal spot with a focusing ring voltage of 2000 V, which was consistent with the simulation results and verified the effectiveness of the optimization algorithm. The optimal focal spot is $0.53\times 0.79$ mm with an imaging resolution of up to 3.9 lp/mm. The system is also capable of dynamic imaging with X-ray pulse widths as short as $50~\mu $ s. Results show that the developed MCP-MPXS solves the problem of insufficient output intensity of traditional MPXSs, realizes high-speed X-ray modulation, and is capable of high-resolution X-ray imaging. This X-ray source has broad application prospects in X-ray communication and high-speed X-ray imaging.
- 15 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 70 (11) , 5877-5882
X-Ray Characteristics of Four-Level Pulse Amplitude Modulation for X-Ray Communication Based on Carbon Nanotube Cold Cathode X-Ray Source
In this work, a pulse amplitude modulation with four-level (PAM-4) signal loading scheme based on carbon nanotube (CNT) cold cathode X-ray source is designed for X-ray communication (XCOM). The relationship between the X-ray waveforms and amplitude characteristics under this scheme is studied, and the XCOM performance is obtained. Results show that the amplitude difference of each level of X-ray waveforms is obvious, and it is corresponding well with the input signal amplitude. The X-ray amplitude difference of each level is 0.7–0.8 V when the ratio of the four pulse voltage signal amplitudes is 1:0.42: −0.12: −1. About 70% of the signal waveforms of each level is relatively concentrated under different frequencies, and this proves the stability and feasibility of the PAM-4 loading scheme. According to the 26-letter American standard code for information interchange (ASCII) code signal transmission experiment, the bit error rate (BER) is increased from 0 to $4.7\times 10^{-{2}}$ when the pulse frequency increases from 1 to 1000 kHz. This work designs a PAM-4 signal loading scheme for XCOM with a CNT cold cathode X-ray source, which can promote the development of XCOM technology in the future.
- 15 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 70 (11) , 5877-5882
X-Ray Characteristics of Four-Level Pulse Amplitude Modulation for X-Ray Communication Based on Carbon Nanotube Cold Cathode X-Ray Source
In this work, a pulse amplitude modulation with four-level (PAM-4) signal loading scheme based on carbon nanotube (CNT) cold cathode X-ray source is designed for X-ray communication (XCOM). The relationship between the X-ray waveforms and amplitude characteristics under this scheme is studied, and the XCOM performance is obtained. Results show that the amplitude difference of each level of X-ray waveforms is obvious, and it is corresponding well with the input signal amplitude. The X-ray amplitude difference of each level is 0.7–0.8 V when the ratio of the four pulse voltage signal amplitudes is 1:0.42: −0.12: −1. About 70% of the signal waveforms of each level is relatively concentrated under different frequencies, and this proves the stability and feasibility of the PAM-4 loading scheme. According to the 26-letter American standard code for information interchange (ASCII) code signal transmission experiment, the bit error rate (BER) is increased from 0 to $4.7\times 10^{-{2}}$ when the pulse frequency increases from 1 to 1000 kHz. This work designs a PAM-4 signal loading scheme for XCOM with a CNT cold cathode X-ray source, which can promote the development of XCOM technology in the future.
- 25 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 40 (13) , 4217-4223
Design and Performance Test of Pulse X-Ray Receiver Based on LYSO-SiPM for X-Ray Communication
X-ray communication (XCOM) is a type of wireless optical communication technology that uses modulated X-ray beam as the carrier of data transmission. As a core component of an XCOM system, the X-ray signal receiver determines the upper limit of the communication rate and the quality of communication. A pulse X-ray signal receiver based on an LYSO-SiPM detector and a field-programmable gate array signal processing module is designed to solve the problems of considerable background noise and weak signal strength in the actual XCOM process. The low bit error rate (BER) at the Mbps rate is realized first for XCOM. An XCOM performance test system is used to test the receiver's signal output characteristics and communication performance. The communication rate reaches 1.21 Mbps with BER less than 1.0 × 10 −5 . The designed pulse X-ray signal receiver can effectively identify X-ray pulse under high bandwidth and weak signal receiving power.
- 25 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 40 (13) , 4217-4223
Design and Performance Test of Pulse X-Ray Receiver Based on LYSO-SiPM for X-Ray Communication
X-ray communication (XCOM) is a type of wireless optical communication technology that uses modulated X-ray beam as the carrier of data transmission. As a core component of an XCOM system, the X-ray signal receiver determines the upper limit of the communication rate and the quality of communication. A pulse X-ray signal receiver based on an LYSO-SiPM detector and a field-programmable gate array signal processing module is designed to solve the problems of considerable background noise and weak signal strength in the actual XCOM process. The low bit error rate (BER) at the Mbps rate is realized first for XCOM. An XCOM performance test system is used to test the receiver's signal output characteristics and communication performance. The communication rate reaches 1.21 Mbps with BER less than 1.0 × 10 −5 . The designed pulse X-ray signal receiver can effectively identify X-ray pulse under high bandwidth and weak signal receiving power.