Direct 17O MRI with partial volume correction: first experiences in a glioblastoma patient
- 1 April 2014
- journal article
- case report
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 27 (6) , 579-587
Abstract
In tumor cells the energy production is shifted from aerobic to anaerobic metabolization of glucose, which makes the cerebral metabolic rate of oxygen consumption (CMRO2) a diagnostic parameter for tissue viability. Direct oxygen-17 (17O) MRI during inhalation of 17O gas allows for a non-invasive determination of the CMRO2. However, the low spatial resolution and the fast transverse relaxation of 17O lead to partial volume effects that severely bias the quantification of signal intensities. The aim of this work was to determine the CMRO2 in a tumor patient by 17O MRI in combination with a partial volume correction (PVC) scheme. Direct 17O MRI was performed in a glioblastoma patient (F, 51 years) prior to surgery at 7 T. The ‘geometric transfer matrix’ algorithm for volume of interest based PVC was adapted to 17O MRI to recover the true signal intensities. We determined the CMRO2 values of gray matter (GM), white matter (WM), cerebrospinal fluid (CSF) and the tumor areas of the contrast enhancing rim (CE), the necrotic center (NE), and the perifocal edema (PE) using a three-phase metabolic model. Large differences in the signal increase during 17O2 inhalation were obtained ranging from less than 2 % in the tumor center up to more than 20 % in GM areas. After PVC of the signal time curves, we determined CMRO2 values of 0.67 ± 0.08 μmol/g/min (WM), 3.57 ± 0.67 μmol/g/min (GM), 0.35 ± 0.09 μmol/g/min (CE), and 0.42 ± 0.05 μmol/g/min (PE). In CSF and NE no oxygen uptake (i.e. CMRO2 = 0) was determined from the corrected signals, well in accordance with the underlying physiology in these regions. The results show that PVC has a strong effect on the resulting CMRO2 values obtained by 17O MRI. We found substantial differences—especially in GM tissue—between corrected and non-corrected CMRO2 values. Additionally, we demonstrated the feasibility of CMRO2 assessment in a glioblastoma patient by 17O MRI.Keywords
This publication has 34 references indexed in Scilit:
- An MR image-guided, voxel-based partial volume correction method for PET imagesMedical Physics, 2011
- A measurement setup for direct 17O MRI at 7 TMagnetic Resonance in Medicine, 2011
- Feasibility of mapping the tissue mass corrected bioscale of cerebral metabolic rate of oxygen consumption using 17-oxygen and 23-sodium MR imaging in a human brain at 9.4TNeuroImage, 2010
- Understanding the Warburg Effect: The Metabolic Requirements of Cell ProliferationScience, 2009
- Mechanical Ventilator for Delivery of 17O2 in Brief PulsesThe Open Biomedical Engineering Journal, 2008
- Regional Hypoxia in Glioblastoma Multiforme Quantified with [18F]Fluoromisonidazole Positron Emission Tomography before Radiotherapy: Correlation with Time to Progression and SurvivalClinical Cancer Research, 2008
- Warburg revisited: imaging tumour blood flow and metabolismCancer Imaging, 2008
- Quantification of Cerebral Blood Flow and Oxygen Metabolism with 3-Dimensional PET and 15O: Validation by Comparison with 2-Dimensional PETJournal of Nuclear Medicine, 2007
- In vivo measurement of T2 distributions and water contents in normal human brainMagnetic Resonance in Medicine, 1997
- In vivo disturbance of the oxidative metabolism of glucose in human cerebral gliomasAnnals of Neurology, 1983