Stefan H. Hoffmann
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Stefan H. Hoffmann has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Armin Michael Nagel
Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-University Erlangen-Nürnberg, Germany (A.M.N.).
2 shared publications Alexander Radbruch
German Cancer Research Center (DKFZ)
1 shared publication- Ana Resetar
Division of Medical Physics in Radiology, German Cancer Research Center (dkfz), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany
1 shared publication - Andreas Graessl
Berlin Ultrahigh Field Facility (B.U.F.F.), Max-Delbrueck-Center for Molecular Medicine, Robert-Roessle-Strasse 10, 13125 Berlin, Germany
1 shared publication - Helmar Waiczies
MRI.TOOLS GmbH Berlin Germany
1 shared publication - Lukas Winter
Physikalisch‐Technische Bundesanstalt (PTB) Braunschweig and Berlin Germany
1 shared publication
Latest Publications
- 1 November 2015
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 33 (9) , 1091-1097
Retrospectively-gated CINE 23Na imaging of the heart at 7.0 Tesla using density-adapted 3D projection reconstruction
- 1 November 2015
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 33 (9) , 1091-1097
Retrospectively-gated CINE 23Na imaging of the heart at 7.0 Tesla using density-adapted 3D projection reconstruction
- 1 April 2014
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 27 (6) , 579-587
Direct 17O MRI with partial volume correction: first experiences in a glioblastoma patient
In tumor cells the energy production is shifted from aerobic to anaerobic metabolization of glucose, which makes the cerebral metabolic rate of oxygen consumption (CMRO2) a diagnostic parameter for tissue viability. Direct oxygen-17 (17O) MRI during inhalation of 17O gas allows for a non-invasive determination of the CMRO2. However, the low spatial resolution and the fast transverse relaxation of 17O lead to partial volume effects that severely bias the quantification of signal intensities. The aim of this work was to determine the CMRO2 in a tumor patient by 17O MRI in combination with a partial volume correction (PVC) scheme. Direct 17O MRI was performed in a glioblastoma patient (F, 51 years) prior to surgery at 7 T. The ‘geometric transfer matrix’ algorithm for volume of interest based PVC was adapted to 17O MRI to recover the true signal intensities. We determined the CMRO2 values of gray matter (GM), white matter (WM), cerebrospinal fluid (CSF) and the tumor areas of the contrast enhancing rim (CE), the necrotic center (NE), and the perifocal edema (PE) using a three-phase metabolic model. Large differences in the signal increase during 17O2 inhalation were obtained ranging from less than 2 % in the tumor center up to more than 20 % in GM areas. After PVC of the signal time curves, we determined CMRO2 values of 0.67 ± 0.08 μmol/g/min (WM), 3.57 ± 0.67 μmol/g/min (GM), 0.35 ± 0.09 μmol/g/min (CE), and 0.42 ± 0.05 μmol/g/min (PE). In CSF and NE no oxygen uptake (i.e. CMRO2 = 0) was determined from the corrected signals, well in accordance with the underlying physiology in these regions. The results show that PVC has a strong effect on the resulting CMRO2 values obtained by 17O MRI. We found substantial differences—especially in GM tissue—between corrected and non-corrected CMRO2 values. Additionally, we demonstrated the feasibility of CMRO2 assessment in a glioblastoma patient by 17O MRI.
- 1 April 2014
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 27 (6) , 579-587
Direct 17O MRI with partial volume correction: first experiences in a glioblastoma patient
In tumor cells the energy production is shifted from aerobic to anaerobic metabolization of glucose, which makes the cerebral metabolic rate of oxygen consumption (CMRO2) a diagnostic parameter for tissue viability. Direct oxygen-17 (17O) MRI during inhalation of 17O gas allows for a non-invasive determination of the CMRO2. However, the low spatial resolution and the fast transverse relaxation of 17O lead to partial volume effects that severely bias the quantification of signal intensities. The aim of this work was to determine the CMRO2 in a tumor patient by 17O MRI in combination with a partial volume correction (PVC) scheme. Direct 17O MRI was performed in a glioblastoma patient (F, 51 years) prior to surgery at 7 T. The ‘geometric transfer matrix’ algorithm for volume of interest based PVC was adapted to 17O MRI to recover the true signal intensities. We determined the CMRO2 values of gray matter (GM), white matter (WM), cerebrospinal fluid (CSF) and the tumor areas of the contrast enhancing rim (CE), the necrotic center (NE), and the perifocal edema (PE) using a three-phase metabolic model. Large differences in the signal increase during 17O2 inhalation were obtained ranging from less than 2 % in the tumor center up to more than 20 % in GM areas. After PVC of the signal time curves, we determined CMRO2 values of 0.67 ± 0.08 μmol/g/min (WM), 3.57 ± 0.67 μmol/g/min (GM), 0.35 ± 0.09 μmol/g/min (CE), and 0.42 ± 0.05 μmol/g/min (PE). In CSF and NE no oxygen uptake (i.e. CMRO2 = 0) was determined from the corrected signals, well in accordance with the underlying physiology in these regions. The results show that PVC has a strong effect on the resulting CMRO2 values obtained by 17O MRI. We found substantial differences—especially in GM tissue—between corrected and non-corrected CMRO2 values. Additionally, we demonstrated the feasibility of CMRO2 assessment in a glioblastoma patient by 17O MRI.