One-dimensional experimental mechanical characterisation of porcine aortic root wall
- 1 March 1999
- journal article
- research article
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 37 (2) , 202-207
Abstract
The human aortic valve, in cases of disease, can be substituted with a stentless biological prosthesis that is made of both porcine aortic root and leaflets. In particular, the aortic root plays a very important part in the opening mechanics of the valve. Therefore, to understand the behaviour of the prosthesis, a knowledge of the mechanical characteristics of each element constituting the system is useful. For a structural and mechanical characterisation of the porcine aortic root wall tissue, specific measuring devices are made. A uni-axial tensile apparatus, operating in a temperature-controlled saline bath, is equipped with special pneumatic clamps. A test rig for the measurement of the specimen cross-sectional area is developed. To determine the porcine aortic root wall mechanical properties, 189 tensile tests are carried out. Specimens of both natural and chemically fixed tissue are used to consider the conditions of both natural valves and prostheses. Tensile tests are carried out on both axial and circumferential specimens taken from 12 areas of one-sixth of the entire aortic root, with the aim of identifying the anisotropic and non-homogeneous behaviour of the tissue. The behaviour changes considerably depending on the direction in which the specimen is strained, the chemical treatment and the zone from which it has been taken. The paper presents the stress-strain characteristics of fresh and fixed tissue in all zones of the aortic wall, both in circumferential and axial directions.Keywords
This publication has 14 references indexed in Scilit:
- Ex vivo biomechanical behavior of abdominal aortic aneurysm: Assessment using a new mathematical modelAnnals of Biomedical Engineering, 1996
- Aortic valve replacement with a stentless porcine aortic valve. A six-year experience.1994
- Natural preload of aortic valve leaflet components during glutaraldehyde fixation: Effects on tissue mechanicsJournal of Biomechanics, 1993
- Micromechanics of the fibrosa and the ventricularis in aortic valve leafletsJournal of Biomechanics, 1992
- Computer-controlled mechanical testing machine for small samples of biological viscoelastic materialsJournal of Biomedical Engineering, 1991
- Analysis of the Medtronic Intact bioprosthetic valve. Effects of "zero-pressure" fixation.1991
- Mechanical testing of cryopreserved aortic allografts. Comparison with xenografts and fresh tissue.1990
- The standardisation of gauge length: Its influence on the relative extensibility of natural and chemically modified pericardiumJournal of Biomechanics, 1986
- The mechanical properties of porcine aortic valve tissuesJournal of Biomechanics, 1983
- DYNAMIC AORTIC ROOT - ITS ROLE IN AORTIC-VALVE FUNCTION1976