Abstract
Rubidium fountain clocks are operated by a control system. In this study, first, the control requirements of a rubidium fountain clock are analyzed; then, a control system is designed and divided into a timing sequence control system, a data acquisition system, and a servo control system. Multiple boards based on PCI extensions for the instrumentation (PXI) bus and Labwindows/CVI software 2019 are adopted. The timing sequence control system outputs 16 transistor–transistor logic (TTL) signals and three arbitrary waveforms. The results show that these signals are synchronized within 380 ns. Moreover, the digital locking frequency of the master laser is triggered by one of the timing signal, sweeping the laser frequency in a wide range during polarization gradient cooling. Two time-of-flight signals are acquired, and Ramsey fringes are scanned using the data acquisition system. An error signal is obtained every two cycles, and it is feed back to the frequency synthesizer and a high resolution offset generator using the servo control system. Then the frequency synthesizer is locked to the Ramsey center resonance. The rubidium atomic fountain clock exhibited a frequency stability of 7.4 × 10−16 at 86,400 s. Moreover, the phase of the Rb fountain clock is compared with that of UTC (NTSC) in real time, demonstrating a frequency drift of 0.00044 ns/day/day. The whole control system is full-featured, robust and flexible, thus satisfying the requirements of rubidium fountain clocks.Keywords
Funding Information
- Natural Science Basic Research Program of Shaanxi Province (2023-JC-YB-078, DSS-WXGZ-2020-0005)
- Large Research Infrastructures Improvement Funds of Chines Academy of Sciences (2023-JC-YB-078, DSS-WXGZ-2020-0005)
This publication has 19 references indexed in Scilit:
- Frequency Stabilization Technology of 1560 nm Fiber Laser Based on Rubidium Modulation Transfer SpectroscopyIEEE Photonics Journal, 2024
- Development and Preliminary Operation of 87Rb Continuously Running Atomic Fountain Clock at NTSCIEEE Transactions on Instrumentation and Measurement, 2022
- Design and operation of a transportable 87Rb atomic fountain clockReview of Scientific Instruments, 2021
- Advances in the accuracy, stability, and reliability of the PTB primary fountain clocksMetrologia, 2018
- Microwave-clock timescale with instability on order of 10−17Metrologia, 2017
- The USNO rubidium fountainsJournal of Physics: Conference Series, 2016
- LabVIEW-based control software for para-hydrogen induced polarization instrumentationReview of Scientific Instruments, 2014
- A distributed, graphical user interface based, computer control system for atomic physics experimentsReview of Scientific Instruments, 2013
- First accuracy evaluation of the NPL-CsF2 primary frequency standardMetrologia, 2010
- Fast line-based experiment timing system for LabVIEWReview of Scientific Instruments, 2004