SFSichen Fan

Sichen Fan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Sichen Fan has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Development of the Ramsey Microwave Cavity for a Time-Keeping 87 Rb Fountain Clock

    by Hui Zhang, Shaojie Yang, Yong Guan, Sichen Fan, Dandan Liu, Yang Bai, Fan Liu, Jun Ruan, Shougang Zhang

    The time-keeping 87Rb fountain clock (TKRFC) is a microwave atomic clock with superior long-term frequency stability. However, as the core component, the Ramsey microwave cavity introduces key limitations for future engineering applications, particularly in system complexity, production consistency, and temperature sensitivity. This paper presents a novel cavity design, offering a new approach to overcoming these challenges. The core innovations are as follows: (1) A structural design incorporating a copper shielding tube and an extended lower end-cap with a cut-off waveguide physically suppresses microwave leakage interference on the atoms. This ensures performance while reducing or even eliminating the need for traditional external microwave interference switches. (2) A fully welded packaging process is employed, providing a viable and standardized solution for both vacuum and microwave sealing. (3) The cavity is designed with a relatively low loaded quality factor (~3120) to minimize temperature-driven cavity pulling frequency shifts. Theoretical and simulation analyses indicate that the cavity exhibits the potential to contribute to a relative frequency stability of the clock output below 1.3 × 10-17. This work explores a potential technical route to address key bottlenecks in the cavity, aiming to facilitate the future engineering application of the clock.

  • Open Access

    Design a Robust Control System for Rubidium Fountain Clock

    by Dandan Liu, Hui Zhang, Yang Bai, Sichen Fan, Jun Ruan, Shougang Zhang

    Rubidium fountain clocks are operated by a control system. In this study, first, the control requirements of a rubidium fountain clock are analyzed; then, a control system is designed and divided into a timing sequence control system, a data acquisition system, and a servo control system. Multiple boards based on PCI extensions for the instrumentation (PXI) bus and Labwindows/CVI software 2019 are adopted. The timing sequence control system outputs 16 transistor–transistor logic (TTL) signals and three arbitrary waveforms. The results show that these signals are synchronized within 380 ns. Moreover, the digital locking frequency of the master laser is triggered by one of the timing signal, sweeping the laser frequency in a wide range during polarization gradient cooling. Two time-of-flight signals are acquired, and Ramsey fringes are scanned using the data acquisition system. An error signal is obtained every two cycles, and it is feed back to the frequency synthesizer and a high resolution offset generator using the servo control system. Then the frequency synthesizer is locked to the Ramsey center resonance. The rubidium atomic fountain clock exhibited a frequency stability of 7.4 × 10−16 at 86,400 s. Moreover, the phase of the Rb fountain clock is compared with that of UTC (NTSC) in real time, demonstrating a frequency drift of 0.00044 ns/day/day. The whole control system is full-featured, robust and flexible, thus satisfying the requirements of rubidium fountain clocks.


  • Open Access

    Frequency Stabilization Technology of 1560 nm Fiber Laser Based on Rubidium Modulation Transfer Spectroscopy

    by Yang Bai, Jun Ruan, Dandan Liu, Sichen Fan, Yong Guan, Pengyue Lei

    The modulation transfer spectroscopy (MTS) technique used to stabilize two different transition lines of rubidium, required for laser cooling of atoms, is investigated. The laser source is based on a 1560 nm semiconductor laser diode that is amplified by an erbium doped fiber amplifier (EDFA). The laser output is frequency doubled with a fiber coupled periodically poled Lithium Niobate (PPLN) crystal to 780 nm. To address the weak spectral features of repumping laser, a theoretical study is conducted followed by experimental verification. The 87Rb D2 line F = 1 → F' = 0 transition temperature-enhanced MTS signal is observed, which provides a choice to stabilize the repumping laser frquency on the F = 1 → F ' = 2 transition using frequency shifting with acousto-optic modulators (AOMs). Compared with the orignal MTS signal, this method is shown to be more stable and accurate for laser frequency locking. Laer frequency locking is realized by controlling the driving current of the seed laser using digital PID feedback. After locking, the laser linewidth is 35.36 kHz.


  • Development and Preliminary Operation of 87Rb Continuously Running Atomic Fountain Clock at NTSC

    by Hui Zhang, Jun Ruan, Dandan Liu, Fan Yang, Sichen Fan, Yang Bai, Yong Guan, Xinliang Wang, Junru Shi, Shougang Zhang

    An atomic clock with excellent long-term stability is important for maintaining the Local Atomic Time (TA(k)). The 87 Rb atomic fountain clock has the potential to fulfill these characteristics. It is required to operate continuously, similar to commercial cesium beam clocks and hydrogen masers. This paper describes the design and preliminary operation results of an 87 Rb atomic fountain continuous clock ( 87 RFCC) developed at the National Time Service Center (NTSC) of the Chinese Academy of Sciences. We adopted some improved design aspects and suppressed Majorana effect and microwave leakage to enhance the clock’s stability. Its continuous operation has been improved owing to the advantages of the high-reliability optical system and servo high-resolution offset generator (HROG) algorithm. We presented an algorithm for the 5 MHz/1 PPS signal output of the 87 RFCC through the HROG. The 87 RFCC exhibited a frequency stability of 1.91×10 -13 τ -1/2 , reaching 4.7×10 -16 at 200000 s. We referenced the 1 PPS output signal to the UTC(NTSC) and obtained the relative phase fluctuation of the 87 RFCC, which was within ±1.75 ns for approximately 90 days. We estimated the preliminary drift of the 87 RFCC relative to the UTC(NTSC) for three different periods at 0.000019±0.00148 ns/d/d, 0.00119±0.00182 ns/d/d, and -0.00155±0.00060 ns/d/d and discussed the results. During the 90-day evaluation period, although the frequency of the 87 RFCC relative to the UTC(NTSC) had changed, it still exhibited a low drift compared to cesium beam clocks and hydrogen masers, which highlights its potential for excellent long-term stability. The 87 RFCC investigated here has the potential to improve the local time scale.


  • Open Access

    Experimental Evaluation of the Blackbody Radiation Shift in the Cesium Atomic Fountain Clock

    by Fan Yang, Xinliang Wang, Jun Ruan, Junru Shi, Sichen Fan, Yang Bai, Yong Guan, Qiang Hao, Hui Zhang, Dandan Liu, et al.

    The cesium atomic fountain clock is the world’s most accurate microwave atomic clock. The uncertainty of blackbody radiation (BBR) shift accounts for an increasingly large percentage of the uncertainty associated with fountain clocks and has become a key factor in the performance of fountain clocks. The uncertainty of BBR shift can be reduced by improving the system environment temperature. This study examined the mechanism by which the BBR shift of the transition frequency between the two hyperfine energy levels of the 133Cs ground state is generated and the calculation method for the BBR shift in the atomic fountain. Methods used to reduce the uncertainty of BBR shift were also examined. A fountain system structure with uniform temperature and good heat preservation was designed, and related technologies, such as that for measuring the temperature of the cesium fountain system, were studied. The results of 20 days of measurements, in combination with computer simulation results, showed that the temperature uncertainty of the atomic action zone is 0.12 °C and that the resulting uncertainty of BBR shift is 2.4 × 10−17.


  • Eelectromagnetic field distribution of whispering gallery mode in a sapphire resonator

    by Si-Chen Fan, Fan Yang, Jun Ruan

    蓝宝石谐振体内的电磁场为回音壁模式时具有极低的介质损耗. 本文采用径向-轴向模式匹配法, 理论分析了蓝宝石谐振体内的场模式分布, 分析了谐振频率与谐振体几何尺寸的关系; 其次, 基于有限元分析仿真了蓝宝石圆柱体内场分布情况; 研制了三维转动位移台, 采用磁环/探针耦合的方式激发蓝宝石谐振体内的回音壁电磁场, 测量了谐振体表面的S参数, 由此确定了谐振体内的回音壁模式参数, 得到谐振器的无载Q值为94000. 利用该谐振体可制成低相位噪声的微波振荡器.