Validation of the femoral component placement during hip resurfacing: a comparison between the conventional jig, patient‐specific template, and CT‐based navigation
- 5 March 2013
- journal article
- research article
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 9 (2) , 223-229
Abstract
Background Appropriate insertion of a femoral guidewire is essential for hip resurfacing. A simulation study was planned using synthetic femoral bone models and the accuracy and precision of femoral guidewire alignment and insertion point were compared between conventional jigs, patient‐specific templates, and computed tomography (CT) based navigation techniques. Methods Anteversion, stem‐shaft angle, and the three‐dimensional insertion point were measured postoperative with CT. Errors between planned and postoperative measurement and precision were evaluated. Results There were no statistically significant differences in error for anteversion or insertion point, although the mechanical jig showed greater error in the stem‐shaft angle than the others. Patient‐specific template and CT‐based navigation showed good precision with high intraclass correlation (ICC) (template, 0.908 to 1.000; navigation, 0.929 to 0.995) and small root mean square error (RMSE) (0.954 to 2.969; 1.468 to 3.213). The mechanical jig group performance was inferior to the others. Conclusions Patient‐specific templates and CT‐based navigation had good accuracy and precision. The mechanical jig technique was inferior to the others. Copyright © 2013 John Wiley & Sons, Ltd.Keywords
This publication has 15 references indexed in Scilit:
- Does CT-Based Navigation Improve the Long-Term Survival in Ceramic-on-Ceramic THA?Clinical Orthopaedics and Related Research, 2012
- Evaluation of the Accuracy of Computed Tomography–Based Navigation for Femoral Stem Orientation and Leg Length DiscrepancyThe Journal of Arthroplasty, 2011
- A Comparison of Conventional Guidewire Alignment Jigs with Imageless Computer Navigation in Hip Resurfacing ArthroplastyJournal of Bone and Joint Surgery, 2010
- A custom-made guide-wire positioning device for Hip Surface Replacement Arthroplasty: description and first resultsBMC Musculoskeletal Disorders, 2010
- Computer-Assisted Hip Resurfacing Using Individualized Drill TemplatesThe Journal of Arthroplasty, 2010
- Femoral Component Positioning in Hip Resurfacing With and Without NavigationClinical Orthopaedics and Related Research, 2009
- Results and Lessons Learned from a United States Hip Resurfacing Investigational Device Exemption TrialJournal of Bone and Joint Surgery, 2008
- Learning How to Resurface Cam-Type Femoral Heads with Acceptable Accuracy and Precision: The Role of Computed Tomography-Based NavigationJournal of Bone and Joint Surgery, 2008
- The accuracy of image-free computer navigation in the placement of the femoral component of the Birmingham Hip ResurfacingThe Journal of Bone and Joint Surgery. British volume, 2007
- Femoral neck fractures following Birmingham hip resurfacingThe Journal of Bone and Joint Surgery. British volume, 2005