Abstract
In this study, the common mode voltage (CMV) of photo-voltaic grid connected inverter (PVGCI) is reduced due to minimal switching constraints and lower PVGCI input dc voltage during low power injection. In the absence of a transformer at the grid side, a high frequency CMV in PVGCI can cause electromagnetic interference, magnetic saturation, and circulating currents among other things. In the literature on reducing CMV, various topologies, control algorithms, and filter components have been used. The design recommended in the paper uses a two-level four-leg inverter with fourteen switching states to reduce CMV. The grid current THD increases as the number of switching states evaluated decreases; however, the approach suggested minimizes grid current THD by decreasing the dc voltage during low-power flow from PVGCI, and the CMV amplitude is determined by PVGCI input dc voltage, which decreases during low-power injection. A cost function of average switching frequency is considered for decreasing the switching frequency of PVGCI. The suggested approach is simulated in MATLAB simulation and a hardware experiment is performed in hardware lab to demonstrate its superiority over existing models.

This publication has 34 references indexed in Scilit: