Electropolymerised Phenolic Films as Internal Barriers for Oxidase Enzyme Biosensors
- 13 November 2013
- journal article
- research article
- Published by Wiley in Electroanalysis
- Vol. 26 (6) , 1335-1344
Abstract
The properties of electropolymerised phenolic films at amperometric needle electrodes were investigated and their applicability as selective, internal barriers for potential in vivo oxidase enzyme based biosensors evaluated. Polyphenol, poly(phenol red) and dual layer poly(phenol red)/poly(4‐aminophenol) films were formed by electropolymerisation and compared with a solvent deposited sulfonated polyether ether sulfonepolyether sulfone (SPEES‐PES) membrane. Phenol red had two distinct cyclic voltammetry peaks on platinum: an oxidative peak at +0.70 V and a reduction peak at −0.2 V vs. Ag/AgCl, respectively. Also, the film enhanced the oxidation of hydrogen peroxide by a factor of 3–4, making it an attractive barrier for oxidase based biosensors. Lactate sensors made with polyphenolic electropolymers and solvent deposited SPEES/PES were compared for selectivity and lactate response; the latter showed better selectivity against acetaminophen but less selectivity against ascorbic acid. When sensors were sterilised by standard gamma – irradiation for in vivo application, the polyphenolic films degraded and lost selectivity, whilst SPEES/PES survived unchanged. Salivary lactate was monitored during exercise with electropolymerised film sensors and demonstrated mean lactate increases of 0.3–0.6 mM.Keywords
This publication has 34 references indexed in Scilit:
- Sulfonated polyphenyl ether by electropolymerizationElectrochimica Acta, 2012
- Electrosynthesized polymers for biosensingChemical Society Reviews, 2011
- Enzyme-based choline and l-glutamate biosensor electrodes on silicon microprobe arraysBiosensors and Bioelectronics, 2010
- Polypyrrole based amperometric glucose biosensorsSensors and Actuators B: Chemical, 2009
- Micromachined sensor for lactate monitoring in salivaBiosensors and Bioelectronics, 2006
- Immobilisation of enzyme throughout a polytyramine matrix: a versatile procedure for fabricating biosensorsAnalytica Chimica Acta, 1999
- Electrochemical characteristics of two model electropolymerised films for enzyme electrodesBiosensors and Bioelectronics, 1996
- Chemical indicators as enhancers of the chemiluminescent luminol-H2O2-horseradish peroxidase reactionJournal of Photochemistry and Photobiology A: Chemistry, 1995
- Microarray electrodes as biosensorsElectroanalysis, 1991
- Electrochemically Modified Electrodes: Poly(2‐Methyl‐8‐Quinolinol) and Poly(8‐Quinolinol) Complexing Films Obtained by Electropolymerizing Substituted Phenols: Their Voltammetric and Electrical Properties in Relation to Their Geometric StructureJournal of the Electrochemical Society, 1983