Anna-Maria Spehar-Deleze
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Anna-Maria Spehar-Deleze has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
Sakari Kulmala
Laboratory of Inorganic and Analytical Chemistry, Helsinki University of Technology, P.O. Box 6100, FIN-02015 HUT, Finland
6 shared publicationsSalzitsa Anastasova
Queen Mary, University of London, Mile End Road, London, E1 4NS, UK
6 shared publicationsQinghong Jiang
Helsinki University of Technology
5 shared publications- Johanna Suomi
Risk Assessment Unit Finnish Food Authority Helsinki Finland
4 shared publications Markus Håkansson
Laboratory of Analytical and Inorganic Chemistry, Helsinki University of Technology, P.O. Box 6100, FIN-02015 HUT, Finland
4 shared publicationsPankaj Vadgama
Queen Mary University of London Mile End Road, E14N, London United Kingdom
4 shared publications
Latest Publications
- 13 November 2013
- Published by Wiley in Electroanalysis
- Vol. 26 (6) , 1335-1344
Electropolymerised Phenolic Films as Internal Barriers for Oxidase Enzyme Biosensors
The properties of electropolymerised phenolic films at amperometric needle electrodes were investigated and their applicability as selective, internal barriers for potential in vivo oxidase enzyme based biosensors evaluated. Polyphenol, poly(phenol red) and dual layer poly(phenol red)/poly(4‐aminophenol) films were formed by electropolymerisation and compared with a solvent deposited sulfonated polyether ether sulfonepolyether sulfone (SPEES‐PES) membrane. Phenol red had two distinct cyclic voltammetry peaks on platinum: an oxidative peak at +0.70 V and a reduction peak at −0.2 V vs. Ag/AgCl, respectively. Also, the film enhanced the oxidation of hydrogen peroxide by a factor of 3–4, making it an attractive barrier for oxidase based biosensors. Lactate sensors made with polyphenolic electropolymers and solvent deposited SPEES/PES were compared for selectivity and lactate response; the latter showed better selectivity against acetaminophen but less selectivity against ascorbic acid. When sensors were sterilised by standard gamma – irradiation for in vivo application, the polyphenolic films degraded and lost selectivity, whilst SPEES/PES survived unchanged. Salivary lactate was monitored during exercise with electropolymerised film sensors and demonstrated mean lactate increases of 0.3–0.6 mM.
- 13 November 2013
- Published by Wiley in Electroanalysis
- Vol. 26 (6) , 1335-1344
Electropolymerised Phenolic Films as Internal Barriers for Oxidase Enzyme Biosensors
The properties of electropolymerised phenolic films at amperometric needle electrodes were investigated and their applicability as selective, internal barriers for potential in vivo oxidase enzyme based biosensors evaluated. Polyphenol, poly(phenol red) and dual layer poly(phenol red)/poly(4‐aminophenol) films were formed by electropolymerisation and compared with a solvent deposited sulfonated polyether ether sulfonepolyether sulfone (SPEES‐PES) membrane. Phenol red had two distinct cyclic voltammetry peaks on platinum: an oxidative peak at +0.70 V and a reduction peak at −0.2 V vs. Ag/AgCl, respectively. Also, the film enhanced the oxidation of hydrogen peroxide by a factor of 3–4, making it an attractive barrier for oxidase based biosensors. Lactate sensors made with polyphenolic electropolymers and solvent deposited SPEES/PES were compared for selectivity and lactate response; the latter showed better selectivity against acetaminophen but less selectivity against ascorbic acid. When sensors were sterilised by standard gamma – irradiation for in vivo application, the polyphenolic films degraded and lost selectivity, whilst SPEES/PES survived unchanged. Salivary lactate was monitored during exercise with electropolymerised film sensors and demonstrated mean lactate increases of 0.3–0.6 mM.
- 23 September 2013
- Published by Royal Society of Chemistry (RSC)
- p. 35-64
Integrated Chemistries for Analytical Simplification and Point of Care Testing
With the convergence of immobilisation chemistries for complex biomolecules and reaction sequences with microfabrication and lamination technologies it is now possible to integrate bench‐level laboratory assays into miniaturised devices. Main‐frame laboratories analysers have retained soluble reagent system capable of high throughput assays by the incorporation of sophisticated fluidics, but the “miniaturised device” approval has seen considerable innovation and diversification in recent years for point of care (POC) diagnosis. It has empowered both patients and clinical staff to undertake timely sampling and analysis with the minimum of specimen manipulation and separation. Sample movement and separation through lateral flow and microfluidics have been a key first step with sample presentation in the right form to a detector or binding surface. There is no reaction product as outcome. A smart adaptation of label‐based assays is necessary and whilst the principles of this may not be new, their design, and means of miniaturised integration are definitely engineering advances. We have come a long way from the original dry reagent concept for extralaboratory testing, but with now more complex chemistries and the prospects of array technologies, POC testing is set to become a more prominent feature of the diagnostic scene.
- 23 September 2013
- Published by Royal Society of Chemistry (RSC)
- p. 35-64
Integrated Chemistries for Analytical Simplification and Point of Care Testing
With the convergence of immobilisation chemistries for complex biomolecules and reaction sequences with microfabrication and lamination technologies it is now possible to integrate bench‐level laboratory assays into miniaturised devices. Main‐frame laboratories analysers have retained soluble reagent system capable of high throughput assays by the incorporation of sophisticated fluidics, but the “miniaturised device” approval has seen considerable innovation and diversification in recent years for point of care (POC) diagnosis. It has empowered both patients and clinical staff to undertake timely sampling and analysis with the minimum of specimen manipulation and separation. Sample movement and separation through lateral flow and microfluidics have been a key first step with sample presentation in the right form to a detector or binding surface. There is no reaction product as outcome. A smart adaptation of label‐based assays is necessary and whilst the principles of this may not be new, their design, and means of miniaturised integration are definitely engineering advances. We have come a long way from the original dry reagent concept for extralaboratory testing, but with now more complex chemistries and the prospects of array technologies, POC testing is set to become a more prominent feature of the diagnostic scene.
- 1 May 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Wearable electronic sensor for potentiometric and amperometric measurements
To enable continuous monitoring of electrochemical sensors outside the laboratories, there is a significant demand on electrochemical measurement systems to be miniaturized. The paper presents a low-cost, portable miniature device for electrochemical measurements. The device consists of a 35mm × 20mm × 25mm wireless tag, which enables potentiometric and amperometric measurement, and a base station for data acquisition. Potentiometric performance is evaluated using solid contact ion selective electrodes for pH and sodium. High sensitivity, repeatability and fast response time have been achieved. Amperometric measurement of hydrogen peroxide shows that the measured current accuracy and sensitivity are comparable to that of a commercial potentiostat. Moreover, the device can be used for lactate concentration sensing.
- 1 May 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Wearable electronic sensor for potentiometric and amperometric measurements
To enable continuous monitoring of electrochemical sensors outside the laboratories, there is a significant demand on electrochemical measurement systems to be miniaturized. The paper presents a low-cost, portable miniature device for electrochemical measurements. The device consists of a 35mm × 20mm × 25mm wireless tag, which enables potentiometric and amperometric measurement, and a base station for data acquisition. Potentiometric performance is evaluated using solid contact ion selective electrodes for pH and sodium. High sensitivity, repeatability and fast response time have been achieved. Amperometric measurement of hydrogen peroxide shows that the measured current accuracy and sensitivity are comparable to that of a commercial potentiostat. Moreover, the device can be used for lactate concentration sensing.
- 4 May 2012
- Published by The Electrochemical Society in ECS Transactions
- Vol. 41 (20) , 43-48
Oxygen Detection Using Different Types of Membranes Deposited on Needle Based Platforms
The aim of this work was to develop needle based sensors for oxygen sensing using different types of membranes. For oxygen sensors it is important to achieve fast response time, good linearity, low biofouling and high sensitivity. The effect of different types of polymeric barrier membranes and their various combinations were assessed and compared. An optimized system was thereby selected: sensors covered with polyurethane membrane doped with surfactant showed good stability with a linear working range up to 750 mmHg pO2.
- 4 May 2012
- Published by The Electrochemical Society in ECS Transactions
- Vol. 41 (20) , 43-48
Oxygen Detection Using Different Types of Membranes Deposited on Needle Based Platforms
The aim of this work was to develop needle based sensors for oxygen sensing using different types of membranes. For oxygen sensors it is important to achieve fast response time, good linearity, low biofouling and high sensitivity. The effect of different types of polymeric barrier membranes and their various combinations were assessed and compared. An optimized system was thereby selected: sensors covered with polyurethane membrane doped with surfactant showed good stability with a linear working range up to 750 mmHg pO2.
- 1 May 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 67 (23768886) , 17-21
Extreme Physiological State: Development of Tissue Lactate Sensor
Lactate is one of the most important biomarkers of tissue oxygenation and thus of paramount importance for sports and health care applications. Lactate levels provide information on anaerobic threshold which is very important for tailoring training programs in endurance sports. In this contribution we present an implantable amperometric lactate sensor for continuous in vivo monitoring. A needle based construction is used where a sensing platinum wire is inserted into a stainless steel tube that serves as a combined counter and reference electrode allowing for easy insertion, small size and minimally invasive procedure. The sensing enzyme layer is sandwiched between two polymer membranes which allow high selectivity, a wide lactate linear range and biocompatibility. The sensors have been fully evaluated in vitro and tested in vivo in rats. The measured values of tissue lactate obtained with our sensors were compared with lactate levels measured in blood by the commercial Lactate Pro analyzer. The obtained concentrations were in the same range, however, no clear correlation between blood and tissue values was found. Coldsterilisation by gamma radiation, required for human studies, is currently being investigated. This work will provide valuable information on lactate levels in different physiological compartments and increase our understanding of physiological processes related to endurance sports.
- 1 May 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 67 (23768886) , 17-21
Extreme Physiological State: Development of Tissue Lactate Sensor
Lactate is one of the most important biomarkers of tissue oxygenation and thus of paramount importance for sports and health care applications. Lactate levels provide information on anaerobic threshold which is very important for tailoring training programs in endurance sports. In this contribution we present an implantable amperometric lactate sensor for continuous in vivo monitoring. A needle based construction is used where a sensing platinum wire is inserted into a stainless steel tube that serves as a combined counter and reference electrode allowing for easy insertion, small size and minimally invasive procedure. The sensing enzyme layer is sandwiched between two polymer membranes which allow high selectivity, a wide lactate linear range and biocompatibility. The sensors have been fully evaluated in vitro and tested in vivo in rats. The measured values of tissue lactate obtained with our sensors were compared with lactate levels measured in blood by the commercial Lactate Pro analyzer. The obtained concentrations were in the same range, however, no clear correlation between blood and tissue values was found. Coldsterilisation by gamma radiation, required for human studies, is currently being investigated. This work will provide valuable information on lactate levels in different physiological compartments and increase our understanding of physiological processes related to endurance sports.
- 5 January 2012
- Published by Springer Nature
- p. 287-303
General Platform for In Vivo Sensors for Oxygen, Glucose and Lactate Monitoring
- 5 January 2012
- Published by Springer Nature
- p. 287-303
General Platform for In Vivo Sensors for Oxygen, Glucose and Lactate Monitoring
- 20 December 2011
- Published by Wiley in Electroanalysis
- Vol. 24 (3) , 529-538
Stabilised Biosensing Using Needle‐Based Recess Electrodes
A recess disk electrode for amperometric monitoring of oxygen and glucose is reported. The basic design of sensor is a needle structure for easy implantation, embodying a gold filled silica capillary with a 80 µm inner diameter working electrode. Recess and inlaid disc electrodes, placed inside stainless steel tubes which served as a counter/reference electrode, were compared. The working electrode surface was modified with different treatments and barrier membranes to achieve selectivity for the analytes of interest. The basic needle format is ideal for in vivo use, and the format is easily extendable to other analyte targets. The sensors show linear working range for oxygen up to 160 mmHg partial pressure of oxygen, and for glucose from 1 to 10 mM. Bio‐fouling, as assessed by exposure to bovine serum albumin, was significantly reduced. Response times for the recess construct was increased but remained within the acceptable range for physiological monitoring. The operational stability of the sensors is demonstrated as well as the interference‐free detection of peroxide in the presence of physiologically relevant levels of ascorbic acid, uric acid, acetaminophen, and catechol. Preliminary in vivo tests showed excellent response towards glucose.
- 20 December 2011
- Published by Wiley in Electroanalysis
- Vol. 24 (3) , 529-538
Stabilised Biosensing Using Needle‐Based Recess Electrodes
A recess disk electrode for amperometric monitoring of oxygen and glucose is reported. The basic design of sensor is a needle structure for easy implantation, embodying a gold filled silica capillary with a 80 µm inner diameter working electrode. Recess and inlaid disc electrodes, placed inside stainless steel tubes which served as a counter/reference electrode, were compared. The working electrode surface was modified with different treatments and barrier membranes to achieve selectivity for the analytes of interest. The basic needle format is ideal for in vivo use, and the format is easily extendable to other analyte targets. The sensors show linear working range for oxygen up to 160 mmHg partial pressure of oxygen, and for glucose from 1 to 10 mM. Bio‐fouling, as assessed by exposure to bovine serum albumin, was significantly reduced. Response times for the recess construct was increased but remained within the acceptable range for physiological monitoring. The operational stability of the sensors is demonstrated as well as the interference‐free detection of peroxide in the presence of physiologically relevant levels of ascorbic acid, uric acid, acetaminophen, and catechol. Preliminary in vivo tests showed excellent response towards glucose.
- 1 January 2011
- Published by Institution of Engineering and Technology (IET)
- p. 53-62
Pervasive sensing for athletic training
Professional sports are increasingly competitive. The difference between a medallist and a participating athlete is often a fraction of a second. In order to maintain and maximise the marginal gain in performance, it is crucial to understand precisely how an athlete performs. Thus far, most of the quantitative analysis of athletic performance is only carried out in highly constrained laboratory environment, and thus the information captured may not reflect the natural competing environment. The ESPRIT (Elite Sport Performance Research in Training) programme aims to develop pervasive sensing technologies to enable real-time, continuous and quantitative measurement of athletic performance during normal training and competition settings. It is designed not only to help secure a competitive advantage for UK athletes, but also to increase our understanding of the biology of athletic performance, thus leading to improvements in the health and wellbeing of the population at large.
- 1 January 2011
- Published by Institution of Engineering and Technology (IET)
- p. 53-62
Pervasive sensing for athletic training
Professional sports are increasingly competitive. The difference between a medallist and a participating athlete is often a fraction of a second. In order to maintain and maximise the marginal gain in performance, it is crucial to understand precisely how an athlete performs. Thus far, most of the quantitative analysis of athletic performance is only carried out in highly constrained laboratory environment, and thus the information captured may not reflect the natural competing environment. The ESPRIT (Elite Sport Performance Research in Training) programme aims to develop pervasive sensing technologies to enable real-time, continuous and quantitative measurement of athletic performance during normal training and competition settings. It is designed not only to help secure a competitive advantage for UK athletes, but also to increase our understanding of the biology of athletic performance, thus leading to improvements in the health and wellbeing of the population at large.
- 23 November 2009
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 26 (3) , 2130-2135
Enhanced Electrochemiluminescence and Charge Transport Through Films of Metallopolymer-Gold Nanoparticle Composites
Water-soluble 4-(dimethylamino) pyridine (DMAP) stabilized gold nanoparticles (DMAP-AuNP) were synthesized by ligand exchange and phase transfer (toluene/water). The DMAP-AuNPs are positively charged with the core diameter of 4 +/- 1 nm. Metallopolymer-gold nanocomposites were prepared by mixing gold nanoparticles and [Ru(bpy)(2)PVP10](ClO4)(2), in water at different mole ratios: bpy is 2,2'-bipyridyl and PVP is poly (4-vinylpyridine). The photoluminescence emission intensity of the metallopolymer decreases with increasing AuNP loading and approximately 57% of the emission intensity is quenched when the Au NP:Ru mole ratio is 14.8 x 10(-2). The rate or homogeneous charge transfer through thin layers of the nanocomposite deposited oil glassy carbon electrodes increases with increasing nanoparticle loading. The homogeneous charge transport diffusion coefficient, D-CT., for the composite (AuNP:Ru mole ratio 13.2 x 10(-2)) is (2.8 +/- 0.8) X 10(-11) cm(-2) s(-1) and is approximately 3-fold higher than that found for the pure metallopolymer. Significantly, despite the ability of the metal nanoparticles to quench the ruthenium-based emission, the electrochemiluminescence of the nanocomposite with a AuNP:Ru mole ratio of 4.95 x 10(-2) is approximately three times more intense than the parent metallopolymer. This enhancement arises from the increased rate of charge transport that leads to it greater number of excited states per unit time while minimizing lie quenching effects. The implications of these findings for the design of electrochemiluminescent sensors are discussed.
- 23 November 2009
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 26 (3) , 2130-2135
Enhanced Electrochemiluminescence and Charge Transport Through Films of Metallopolymer-Gold Nanoparticle Composites
Water-soluble 4-(dimethylamino) pyridine (DMAP) stabilized gold nanoparticles (DMAP-AuNP) were synthesized by ligand exchange and phase transfer (toluene/water). The DMAP-AuNPs are positively charged with the core diameter of 4 +/- 1 nm. Metallopolymer-gold nanocomposites were prepared by mixing gold nanoparticles and [Ru(bpy)(2)PVP10](ClO4)(2), in water at different mole ratios: bpy is 2,2'-bipyridyl and PVP is poly (4-vinylpyridine). The photoluminescence emission intensity of the metallopolymer decreases with increasing AuNP loading and approximately 57% of the emission intensity is quenched when the Au NP:Ru mole ratio is 14.8 x 10(-2). The rate or homogeneous charge transfer through thin layers of the nanocomposite deposited oil glassy carbon electrodes increases with increasing nanoparticle loading. The homogeneous charge transport diffusion coefficient, D-CT., for the composite (AuNP:Ru mole ratio 13.2 x 10(-2)) is (2.8 +/- 0.8) X 10(-11) cm(-2) s(-1) and is approximately 3-fold higher than that found for the pure metallopolymer. Significantly, despite the ability of the metal nanoparticles to quench the ruthenium-based emission, the electrochemiluminescence of the nanocomposite with a AuNP:Ru mole ratio of 4.95 x 10(-2) is approximately three times more intense than the parent metallopolymer. This enhancement arises from the increased rate of charge transport that leads to it greater number of excited states per unit time while minimizing lie quenching effects. The implications of these findings for the design of electrochemiluminescent sensors are discussed.
- 20 March 2009
- Published by The Electrochemical Society in ECS Transactions
- Vol. 16 (28) , 69-76
Near infrared Emitting Electrochemiluminescent Ruthenium Polymer
A ruthenium polymer in which two complexes, [Ru(dp-phen)2]2+ (RuN6) and [Ru(dp-phen)2Cl]+ (RuN5Cl), were bound to PVP polymer backbone was synthesized and characterized; dp-phen is 4,7 - diphenyl- 1,10-phenanthroline and PVP is poly(4-vinylpyri-dine). Polymer solution in acetonitrile has two photoluminescence emission peaks, one centered at 620 nm belonging to the RuN6 complex, and a second one at 720 nm corresponding to the RuN5Cl complex. In aqueous solutions and films only one peak centered at 720 nm is present, indicating efficient energy transfer from RuN6 to RuN5Cl centers. Electrochemiluminescence (ECL) is generated in two steps: first the RuN6 centers are oxidized and react with the analyte present, e.g. oxalate, to form an excited ruthenium species, and in the second step, the excited state energy is transferred to the lower energy RuN5Cl centers, which leads to the emission at 720 nm. We also investigated thepossibility of ECL multiplex analysis of guanosine and 8-oxoguanosine.
- 20 March 2009
- Published by The Electrochemical Society in ECS Transactions
- Vol. 16 (28) , 69-76
Near infrared Emitting Electrochemiluminescent Ruthenium Polymer
A ruthenium polymer in which two complexes, [Ru(dp-phen)2]2+ (RuN6) and [Ru(dp-phen)2Cl]+ (RuN5Cl), were bound to PVP polymer backbone was synthesized and characterized; dp-phen is 4,7 - diphenyl- 1,10-phenanthroline and PVP is poly(4-vinylpyri-dine). Polymer solution in acetonitrile has two photoluminescence emission peaks, one centered at 620 nm belonging to the RuN6 complex, and a second one at 720 nm corresponding to the RuN5Cl complex. In aqueous solutions and films only one peak centered at 720 nm is present, indicating efficient energy transfer from RuN6 to RuN5Cl centers. Electrochemiluminescence (ECL) is generated in two steps: first the RuN6 centers are oxidized and react with the analyte present, e.g. oxalate, to form an excited ruthenium species, and in the second step, the excited state energy is transferred to the lower energy RuN5Cl centers, which leads to the emission at 720 nm. We also investigated thepossibility of ECL multiplex analysis of guanosine and 8-oxoguanosine.