Effectiveness and robustness of an asymmetric nonlinear energy sink‐inerter for dynamic response mitigation
- 5 January 2021
- journal article
- research article
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 50 (6) , 1628-1650
Abstract
Nonlinear energy sinks (NESs) have outperformed tuned mass dampers in mitigating undesired responses against changes in structural frequencies. However, the dilemma of gaining frequency robustness at the cost of energy sensitivity as well as the large masses of devices required for civil engineering structures impede the applications of existing NESs. To solve the issue of lacking energy robustness and take advantage of inerters to reduce physical mass, an asymmetric NES‐inerter (Asym NESI) is developed in this study. This passive inerter‐based nonlinear mass damper is configured based on an energy‐robust NES with an inerter added between the auxiliary mass and a fixed point. The paper commences with the formulation of the Asym NESI through mathematical derivations. Then an Asym NESI is designed and evaluated on a three‐story structure in comparison with other counterpart mass dampers. The effectiveness of the Asym NESI can be attributed to its unique dynamics which are revealed analytically using the harmonic balance method through free vibrations and harmonically forced vibrations. The ensuing numerical validations show that due to the integrated linear and nonlinear dynamics of the Asym NESI, the proposed device exhibits strong robustness against changes in both structural frequency and energy level. Moreover, driven by the large inertial effect induced by the auxiliary inerter, the Asym NESI shows flexibility in choosing a practical installation location without sacrificing excellent control capacity. Importantly, the benefits of the Asym NESI are further confirmed by the responses subjected to a suite of ground motions. This study provides analytical insights into the effectiveness and robustness of Asym NESIs and demonstrates substantial performance enhancement by the inerter in structural response mitigation.Keywords
Funding Information
- National Natural Science Foundation of China (52078151, 51978182)
This publication has 50 references indexed in Scilit:
- Seismic control of single‐degree‐of‐freedom structure using tuned viscous mass damperEarthquake Engineering & Structural Dynamics, 2012
- Effective Stiffening and Damping Enhancement of Structures With Strongly Nonlinear Local AttachmentsJournal of Vibration and Acoustics, 2012
- Targeted energy transfer with parallel nonlinear energy sinks. Part I: Design theory and numerical resultsNonlinear Dynamics, 2011
- Mitigation of wind‐induced response of Shanghai Center Tower by tuned mass damperThe Structural Design of Tall and Special Buildings, 2010
- Optimum design of linear tuned mass dampers for structures with nonlinear behaviourMechanical Systems and Signal Processing, 2010
- Mitigation of wind‐induced motion of Milad Tower by tuned mass damperThe Structural Design of Tall and Special Buildings, 2008
- Optimum parameters of tuned mass damper for damped main systemStructural Control and Health Monitoring, 2006
- Experimental study of non-linear energy pumping occurring at a single fast frequencyInternational Journal of Non-Linear Mechanics, 2005
- State of the Art of Structural ControlJournal of Structural Engineering, 2003
- Inducing Passive Nonlinear Energy Sinks in Vibrating SystemsJournal of Vibration and Acoustics, 2001