Abstract
The aberrations induced by the sample and/or by the sample holder limit the resolution of optical microscopes. Wavefront correction can be achieved using a deformable mirror with wavefront sensorless optimization algorithms but, despite the complexity of these systems, the level of correction is often limited to a small area in the field of view of the microscope. In this work, we present a plug and play module for aberration measurement and correction. The wavefront correction is performed through direct wavefront reconstruction using the spinning-pupil aberration measurement and controlling a deformable lens in closed loop. The lens corrects the aberrations in the center of the field of view, leaving residual aberrations at the margins, that are removed by anisoplanatic deconvolution. We present experimental results obtained in fluorescence microscopy, with a wide field and a light sheet fluorescence microscope. These results indicate that detection and correction over the full field of view can be achieved with a compact transmissive module placed in the detection path of the fluorescence microscope.Keywords
All Related Versions
Funding Information
- Office of Naval Research Global (GRANT12789919)
- H2020 Marie Skłodowska-Curie Actions (799230)
- Laserlab-Europe (871124)
This publication has 25 references indexed in Scilit:
- Wavefront correction and high-resolution in vivo OCT imaging with an objective integrated multi-actuator adaptive lensOptics Express, 2015
- Conjugate adaptive optics in widefield microscopy with an extended-source wavefront sensorOptica, 2015
- Adaptive optical microscopy: the ongoing quest for a perfect imageLight: Science & Applications, 2014
- Structural and molecular interrogation of intact biological systemsNature, 2013
- High-resolution imaging of entire organs by 3-dimensional imaging of solvent cleared organs (3DISCO)Experimental Neurology, 2013
- Dual Conjugate Adaptive Optics Prototype for Wide Field High Resolution Retinal Imaging2012
- Three-dimensional imaging of solvent-cleared organs using 3DISCONature Protocols, 2012
- Multilayer mounting enables long-term imaging of zebrafish development in a light sheet microscopeDevelopment, 2012
- Adaptive optics via pupil segmentation for high-resolution imaging in biological tissuesNature Methods, 2009
- Adaptive-optics corrections available for the whole skyNature, 2000