Gianmaria Calisesi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Gianmaria Calisesi has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
Andrea Bassi
Politecnico di Milano Department of Physics 20133 Milano, Italy
3 shared publications- Andrea Farina
Istituto di fotonica e nanotecnologie
3 shared publications - Daniele Ancora
Politecnico di Milano
3 shared publications - Andrea Bassi
Dipartimento di Fisica, Politecnico di Milano, Piazza Leonardo da Vinci 32, I-20133 Milano, Italy
2 shared publications Gianluca Valentini
Politecnico di Milano Department of Physics 20133 Milano, Italy
2 shared publications- Gianluca Valentini
Dipartimento di Fisica, Politecnico di Milano, Milano, Italy
2 shared publications
Latest Publications
- 2 August 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (17) , 30246-30259
Integrated optical device for Structured Illumination Microscopy
Structured Illumination Microscopy (SIM) is a key technology for high resolution and super-resolution imaging of biological cells and molecules. The spread of portable and easy-to-align SIM systems requires the development of novel methods to generate a light pattern and to shift it across the field of view of the microscope. Here we show a miniaturized chip that incorporates optical waveguides, splitters, and phase shifters, to generate a 2D structured illumination pattern suitable for SIM microscopy. The chip creates three point-sources, coherent and controlled in phase, without the need for further alignment. Placed in the pupil of a microscope’s objective, the three sources generate a hexagonal illumination pattern on the sample, which is spatially translated thanks to thermal phase shifters. We validate and use the chip, upgrading a commercial inverted fluorescence microscope to a SIM setup and we image biological sample slides, extending the resolution of the microscope.
- 2 August 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (17) , 30246-30259
Integrated optical device for Structured Illumination Microscopy
Structured Illumination Microscopy (SIM) is a key technology for high resolution and super-resolution imaging of biological cells and molecules. The spread of portable and easy-to-align SIM systems requires the development of novel methods to generate a light pattern and to shift it across the field of view of the microscope. Here we show a miniaturized chip that incorporates optical waveguides, splitters, and phase shifters, to generate a 2D structured illumination pattern suitable for SIM microscopy. The chip creates three point-sources, coherent and controlled in phase, without the need for further alignment. Placed in the pupil of a microscope’s objective, the three sources generate a hexagonal illumination pattern on the sample, which is spatially translated thanks to thermal phase shifters. We validate and use the chip, upgrading a commercial inverted fluorescence microscope to a SIM setup and we image biological sample slides, extending the resolution of the microscope.
- Open Access
- 14 June 2022
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 28 (5) , 1622-1631
Enlarged Field of View in Spatially Modulated Selective Volume Illumination Microscopy
Three-dimensional fluorescence microscopy is a key technology for inspecting biological samples, ranging from single cells to entire organisms. We recently proposed a novel approach called spatially modulated Selective Volume Illumination Microscopy (smSVIM) to suppress illumination artifacts and to reduce the required number of measurements using an LED source. Here, we discuss a new strategy based on smSVIM for imaging large transparent specimens or voluminous chemically cleared tissues. The strategy permits steady mounting of the sample, achieving uniform resolution over a large field of view thanks to the synchronized motion of the illumination lens and the camera rolling shutter. Aided by a tailored deconvolution method for image reconstruction, we demonstrate significant improvement of the resolution at different magnification using samples of varying sizes and spatial features.
- 14 June 2022
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 28 (5) , 1622-1631
Open AccessEnlarged Field of View in Spatially Modulated Selective Volume Illumination Microscopy
Three-dimensional fluorescence microscopy is a key technology for inspecting biological samples, ranging from single cells to entire organisms. We recently proposed a novel approach called spatially modulated Selective Volume Illumination Microscopy (smSVIM) to suppress illumination artifacts and to reduce the required number of measurements using an LED source. Here, we discuss a new strategy based on smSVIM for imaging large transparent specimens or voluminous chemically cleared tissues. The strategy permits steady mounting of the sample, achieving uniform resolution over a large field of view thanks to the synchronized motion of the illumination lens and the camera rolling shutter. Aided by a tailored deconvolution method for image reconstruction, we demonstrate significant improvement of the resolution at different magnification using samples of varying sizes and spatial features.
- Open Access
- 1 January 2022
- Published by Elsevier in Progress in Biophysics and Molecular Biology
- Vol. 168, 66-80
Compressed sensing in fluorescence microscopy
- 1 January 2022
- Published by Elsevier in Progress in Biophysics and Molecular Biology
- Vol. 168, 66-80
Open AccessCompressed sensing in fluorescence microscopy
- 9 December 2021
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 13 (1) , 262-273
Aberration measurement and correction on a large field of view in fluorescence microscopy
The aberrations induced by the sample and/or by the sample holder limit the resolution of optical microscopes. Wavefront correction can be achieved using a deformable mirror with wavefront sensorless optimization algorithms but, despite the complexity of these systems, the level of correction is often limited to a small area in the field of view of the microscope. In this work, we present a plug and play module for aberration measurement and correction. The wavefront correction is performed through direct wavefront reconstruction using the spinning-pupil aberration measurement and controlling a deformable lens in closed loop. The lens corrects the aberrations in the center of the field of view, leaving residual aberrations at the margins, that are removed by anisoplanatic deconvolution. We present experimental results obtained in fluorescence microscopy, with a wide field and a light sheet fluorescence microscope. These results indicate that detection and correction over the full field of view can be achieved with a compact transmissive module placed in the detection path of the fluorescence microscope.
- 9 December 2021
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 13 (1) , 262-273
Aberration measurement and correction on a large field of view in fluorescence microscopy
The aberrations induced by the sample and/or by the sample holder limit the resolution of optical microscopes. Wavefront correction can be achieved using a deformable mirror with wavefront sensorless optimization algorithms but, despite the complexity of these systems, the level of correction is often limited to a small area in the field of view of the microscope. In this work, we present a plug and play module for aberration measurement and correction. The wavefront correction is performed through direct wavefront reconstruction using the spinning-pupil aberration measurement and controlling a deformable lens in closed loop. The lens corrects the aberrations in the center of the field of view, leaving residual aberrations at the margins, that are removed by anisoplanatic deconvolution. We present experimental results obtained in fluorescence microscopy, with a wide field and a light sheet fluorescence microscope. These results indicate that detection and correction over the full field of view can be achieved with a compact transmissive module placed in the detection path of the fluorescence microscope.
- 17 October 2019
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 10 (11) , 5776-5788
Spatially modulated illumination allows for light sheet fluorescence microscopy with an incoherent source and compressive sensing
Light sheet fluorescence microscopy has become one of the most widely used techniques for three-dimensional imaging due to its high speed and low phototoxicity. Further improvements in 3D microscopy require limiting the light exposure of the sample and increasing the volumetric acquisition rate. We hereby present an imaging technique that allows volumetric reconstruction of the fluorescent sample using spatial modulation on a selective illumination volume. We demonstrate that this can be implemented using an incoherent LED source, avoiding shadowing artifacts, typical of light sheet microscopy. Furthermore, we show that spatial modulation allows the use of Compressive Sensing, reducing the number of modulation patterns to be acquired. We present results on zebrafish embryos which prove that selective spatial modulation can be used to reconstruct relatively large volumes without any mechanical movement. The technique yields an accurate reconstruction of the sample anatomy even at significant compression ratios, achieving higher volumetric acquisition rate and reducing photodamage biological samples.
- 17 October 2019
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 10 (11) , 5776-5788
Spatially modulated illumination allows for light sheet fluorescence microscopy with an incoherent source and compressive sensing
Light sheet fluorescence microscopy has become one of the most widely used techniques for three-dimensional imaging due to its high speed and low phototoxicity. Further improvements in 3D microscopy require limiting the light exposure of the sample and increasing the volumetric acquisition rate. We hereby present an imaging technique that allows volumetric reconstruction of the fluorescent sample using spatial modulation on a selective illumination volume. We demonstrate that this can be implemented using an incoherent LED source, avoiding shadowing artifacts, typical of light sheet microscopy. Furthermore, we show that spatial modulation allows the use of Compressive Sensing, reducing the number of modulation patterns to be acquired. We present results on zebrafish embryos which prove that selective spatial modulation can be used to reconstruct relatively large volumes without any mechanical movement. The technique yields an accurate reconstruction of the sample anatomy even at significant compression ratios, achieving higher volumetric acquisition rate and reducing photodamage biological samples.