Design and path tracking control of a continuum robot for maxillary sinus surgery
- 29 December 2022
- journal article
- research article
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 18 (4) , 753-761
Abstract
Purpose Continuum robots (CRs) have been developed for maxillary sinus surgery (MSS) in recent years. However, due to the anatomically curved and narrow pathway of the maxillary sinus and the deformable characteristics of the CR, it is still a challenge to accurately approach the target in the sinus. Thus, the CR-assisted MSS demands further research, whether in robotic system design or in reliable motion control. Methods A continuum robotic system integrated with essential instruments and sensors for MSS is developed, and the path tracking control of the designed CR is studied. The differential kinematic model of the CR is constructed. By analyzing the potential problem of the traditional Jacobian-based control, an iterative Jacobian transpose-based closed-loop control method is proposed to improve the path tracking performance. To validate the design of the CR and the effectiveness of the proposed control scheme, different groups of experiments are performed. Results With the proposed method, the path tracking performance of the CR is improved. Compared with the open-loop Jacobian transpose-based control method, the path tracking error of the proposed method is much less. The maxillary sinus phantom tests are conducted to verify the reachability of the designed CR. Given the reference path from the nostril to the target in the maxillary sinus phantom, experiments show a mean error of 0.96 mm. Conclusions The designed CR is slender, flexible, and able to smoothly approach the target in a tortuous and constrained environment without colliding with or damaging the surrounding tissue. The designed continuum robotic system and the proposed iterative Jacobian transpose-based closed-loop control strategy have great potential for MSS. The limitations of the proposed method are also discussed.Keywords
Funding Information
- National Natural Science Foundation of China (62133009, 61973211, M-0221)
- Science and Technology Commission of Shanghai Municipality (21550714200)
- Project of Institute of Medical Robotics of Shanghai Jiao Tong University
This publication has 21 references indexed in Scilit:
- Iterative Jacobian-Based Inverse Kinematics and Open-Loop Control of an MRI-Guided Magnetically Actuated Steerable Catheter SystemIEEE/ASME Transactions on Mechatronics, 2017
- Design and control of a tendon-driven continuum robotTransactions of the Institute of Measurement and Control, 2017
- Continuum Robots for Medical Applications: A SurveyIEEE Transactions on Robotics, 2015
- Development of the SJTU Unfoldable Robotic System (SURS) for Single Port LaparoscopyIEEE/ASME Transactions on Mechatronics, 2014
- Closed-Loop Inverse Kinematics for Redundant Robots: Comparative Assessment and Two EnhancementsIEEE/ASME Transactions on Mechatronics, 2014
- Maxillary sinus disease: diagnosis and treatmentBritish Dental Journal, 2011
- Design and Kinematic Modeling of Constant Curvature Continuum Robots: A ReviewThe International Journal of Robotics Research, 2010
- Robotics2009
- Selectively Damped Least Squares for Inverse KinematicsJournal of Graphics Tools, 2005
- Kinematics and the Implementation of an Elephant's Trunk Manipulator and Other Continuum Style RobotsJournal of Robotic Systems, 2003