Zefeng Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Zefeng Liu has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Le Xie
Harvard University
8 shared publications - Yongfeng Cao
School of Materials Science and Engineering and the Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai, China
8 shared publications - Wentuo Yang
School of Materials Science and Engineering and the Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai, China
3 shared publications - Fan Feng
School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai, China
2 shared publications - Shuang Wang
Shanghai Key Laboratory of Flexible Medical Robotics, Tongren Hospital, Shanghai, China
2 shared publications - Wuzhou Hong
Institute of Forming Technology and Equipment, Shanghai Jiao Tong University,China
2 shared publications
Latest Publications
- 24 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (1) , 973-983
Temperature-Based Contact Sensing and Force Estimation for Discrete-Jointed Continuum Robots
Contact force is a critical feedback mechanism for ensuring safe robot-environment interactions. Integrating dedicated force sensors into continuum robots (CRs) is difficult due to strict size constraints. Consequently, estimating contact forces based on the robot’s shape/curvature feedback has gained widespread recognition. This involves solving an optimization problem that minimizes the discrepancy between predicted and actual shapes/curvatures. However, this optimization problem is typically high-dimensional, which often leads the optimization to converge to local minima. This article introduces a novel framework for external force estimation based on temperature sensing. The number of external forces, their application points and directions are uniquely determined from the temperature variation during CR-human contact. These identified parameters are incorporated as known inputs into the optimization problem, substantially reducing its dimensionality and consequently improving global convergence, estimation accuracy, and computational efficiency. Based on the CR shape obtained from electromagnetic sensors, force estimation under conditions of known and unknown contact information was compared through simulations and experiments. Results show that the proposed framework significantly improves global convergence compared with methods without contact information, while also greatly reducing computation time. Furthermore, the framework requires only a few compact temperature sensors, which do not increase the overall size of the CR.
- 24 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (1) , 973-983
Temperature-Based Contact Sensing and Force Estimation for Discrete-Jointed Continuum Robots
Contact force is a critical feedback mechanism for ensuring safe robot-environment interactions. Integrating dedicated force sensors into continuum robots (CRs) is difficult due to strict size constraints. Consequently, estimating contact forces based on the robot’s shape/curvature feedback has gained widespread recognition. This involves solving an optimization problem that minimizes the discrepancy between predicted and actual shapes/curvatures. However, this optimization problem is typically high-dimensional, which often leads the optimization to converge to local minima. This article introduces a novel framework for external force estimation based on temperature sensing. The number of external forces, their application points and directions are uniquely determined from the temperature variation during CR-human contact. These identified parameters are incorporated as known inputs into the optimization problem, substantially reducing its dimensionality and consequently improving global convergence, estimation accuracy, and computational efficiency. Based on the CR shape obtained from electromagnetic sensors, force estimation under conditions of known and unknown contact information was compared through simulations and experiments. Results show that the proposed framework significantly improves global convergence compared with methods without contact information, while also greatly reducing computation time. Furthermore, the framework requires only a few compact temperature sensors, which do not increase the overall size of the CR.
- Open Access
- 10 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 48202-48211
Active Disturbance Rejection Control With Data-Driven Compensation for a Novel Extensible Continuum Robot
Continuum robots (CRs) are widely used in minimally invasive surgery due to their inherent flexibility, compliance, and ease of miniaturization. To overcome the limitations of existing CRs in terms of operation dexterity, we design a novel extensible CR that combines spring structures and rod actuation. This design features a slim profile, large working channels, and the ability to independently control both bending length and curvature, enabling a wide range of configurations and enhanced dexterity. On the other hand, due to the nonlinear deformation and infinite degrees of freedom of the CR, controlling the robot presents many challenges, including nonlinearity and uncertainties. Thus, we propose an active disturbance rejection control with data-driven compensation (ADRC-DDC). This method uses a constant curvature model to capture the main dynamic behavior of the CR and combines data-driven disturbance estimation and disturbance estimation from an extended state observer (ESO). The proposed method can better handle system uncertainties, alleviate the burden on the ESO, and improve both robustness and control performance. Experimental results demonstrate the superiority of the designed extensible CR and the proposed ADRCDDC method.
- 10 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 48202-48211
Open AccessActive Disturbance Rejection Control With Data-Driven Compensation for a Novel Extensible Continuum Robot
Continuum robots (CRs) are widely used in minimally invasive surgery due to their inherent flexibility, compliance, and ease of miniaturization. To overcome the limitations of existing CRs in terms of operation dexterity, we design a novel extensible CR that combines spring structures and rod actuation. This design features a slim profile, large working channels, and the ability to independently control both bending length and curvature, enabling a wide range of configurations and enhanced dexterity. On the other hand, due to the nonlinear deformation and infinite degrees of freedom of the CR, controlling the robot presents many challenges, including nonlinearity and uncertainties. Thus, we propose an active disturbance rejection control with data-driven compensation (ADRC-DDC). This method uses a constant curvature model to capture the main dynamic behavior of the CR and combines data-driven disturbance estimation and disturbance estimation from an extended state observer (ESO). The proposed method can better handle system uncertainties, alleviate the burden on the ESO, and improve both robustness and control performance. Experimental results demonstrate the superiority of the designed extensible CR and the proposed ADRCDDC method.
- 29 May 2024
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 19 (9) , 1809-1820
Development of a continuum manipulator with variable bending length and piecewise stiffness for transoral laryngeal surgery
Purpose Continuum manipulators (CMs) show great potential in transoral laryngeal surgery due to their flexibility. However, CMs for transoral surgery face several issues: large size, which reduces practicality; intersegment coupling, which causes undesired deflection; and a lack of versatility that limits their applicability across different patient groups. Methods This work combines a rod-driven proximal segment and a cable-driven distal segment to achieve piecewise stiffness, alleviating the issue of intersegment coupling. A rigid constraint tube is integrated into the proximal segment to diversify its bending behavior. Preliminary experiments are conducted to validate the design concept. Results The proposed CM has an overall diameter of only 6.5 mm. The proximal segment can achieve a 90° bending with various curvatures. At the working configuration, the coupling error between the proximal segment and the distal segment is less than 1 mm. The effectiveness of the proposed CM is successfully validated using a human model. Conclusion The proposed continuum manipulator possesses the desirable characteristics of small size, low coupling, and high versatility, indicating its great potentialities for the diagnosis and treatment of laryngeal lesion.
- 29 May 2024
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 19 (9) , 1809-1820
Development of a continuum manipulator with variable bending length and piecewise stiffness for transoral laryngeal surgery
Purpose Continuum manipulators (CMs) show great potential in transoral laryngeal surgery due to their flexibility. However, CMs for transoral surgery face several issues: large size, which reduces practicality; intersegment coupling, which causes undesired deflection; and a lack of versatility that limits their applicability across different patient groups. Methods This work combines a rod-driven proximal segment and a cable-driven distal segment to achieve piecewise stiffness, alleviating the issue of intersegment coupling. A rigid constraint tube is integrated into the proximal segment to diversify its bending behavior. Preliminary experiments are conducted to validate the design concept. Results The proposed CM has an overall diameter of only 6.5 mm. The proximal segment can achieve a 90° bending with various curvatures. At the working configuration, the coupling error between the proximal segment and the distal segment is less than 1 mm. The effectiveness of the proposed CM is successfully validated using a human model. Conclusion The proposed continuum manipulator possesses the desirable characteristics of small size, low coupling, and high versatility, indicating its great potentialities for the diagnosis and treatment of laryngeal lesion.
- 18 April 2024
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 19 (9) , 1783-1795
Design and navigation method of a soft robot for single-port transvesical radical prostatectomy
Purpose Currently, the rigid instruments used for laparoscopic radical resection of prostate cancer not only have the risk of damage to tissues, blood vessels, and nerves, but their limited freedom will also cause surgical blind areas. Soft robots are expected to solve these issues due to inherent flexibility, compliance, and safe interaction with tissues and organs. In addition, to achieve high surgical accuracy and provide precise guidance for surgeons, the navigation method should be studied for the soft robot. Methods A soft robot system for single-port transvesical radical prostatectomy (STRP) is developed, and a navigation method combining fiber Bragg gratings and electromagnetic tracking is proposed for the soft robot. To validate the soft robot design and the effectiveness of the navigation method, different groups of experiments are conducted. Results The proposed navigation method can achieve accurate location and shape sensing of the soft manipulator. The experiments show that the maximum tip sensing error is 2.691 mm, which is 5.38\(\%\) of the robot length for static configurations, and that the average tip sensing error is 1.966 mm, which corresponds to 3.93\(\%\) of the robot length for dynamic scenarios. Additionally, phantom tests demonstrate that the designed soft robot can enter the prostate through navigation guidance in a master–slave control mode and cover the entire prostate space. Conclusions The designed soft robot system, due to its soft structure, good flexibility, and accurate navigation, is expected to improve surgical safety and precision, thereby exhibiting significant potential for STRP.- 18 April 2024
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 19 (9) , 1783-1795
Design and navigation method of a soft robot for single-port transvesical radical prostatectomy
Purpose Currently, the rigid instruments used for laparoscopic radical resection of prostate cancer not only have the risk of damage to tissues, blood vessels, and nerves, but their limited freedom will also cause surgical blind areas. Soft robots are expected to solve these issues due to inherent flexibility, compliance, and safe interaction with tissues and organs. In addition, to achieve high surgical accuracy and provide precise guidance for surgeons, the navigation method should be studied for the soft robot. Methods A soft robot system for single-port transvesical radical prostatectomy (STRP) is developed, and a navigation method combining fiber Bragg gratings and electromagnetic tracking is proposed for the soft robot. To validate the soft robot design and the effectiveness of the navigation method, different groups of experiments are conducted. Results The proposed navigation method can achieve accurate location and shape sensing of the soft manipulator. The experiments show that the maximum tip sensing error is 2.691 mm, which is 5.38\(\%\) of the robot length for static configurations, and that the average tip sensing error is 1.966 mm, which corresponds to 3.93\(\%\) of the robot length for dynamic scenarios. Additionally, phantom tests demonstrate that the designed soft robot can enter the prostate through navigation guidance in a master–slave control mode and cover the entire prostate space. Conclusions The designed soft robot system, due to its soft structure, good flexibility, and accurate navigation, is expected to improve surgical safety and precision, thereby exhibiting significant potential for STRP.- 29 December 2022
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 18 (4) , 753-761
Design and path tracking control of a continuum robot for maxillary sinus surgery
Purpose Continuum robots (CRs) have been developed for maxillary sinus surgery (MSS) in recent years. However, due to the anatomically curved and narrow pathway of the maxillary sinus and the deformable characteristics of the CR, it is still a challenge to accurately approach the target in the sinus. Thus, the CR-assisted MSS demands further research, whether in robotic system design or in reliable motion control. Methods A continuum robotic system integrated with essential instruments and sensors for MSS is developed, and the path tracking control of the designed CR is studied. The differential kinematic model of the CR is constructed. By analyzing the potential problem of the traditional Jacobian-based control, an iterative Jacobian transpose-based closed-loop control method is proposed to improve the path tracking performance. To validate the design of the CR and the effectiveness of the proposed control scheme, different groups of experiments are performed. Results With the proposed method, the path tracking performance of the CR is improved. Compared with the open-loop Jacobian transpose-based control method, the path tracking error of the proposed method is much less. The maxillary sinus phantom tests are conducted to verify the reachability of the designed CR. Given the reference path from the nostril to the target in the maxillary sinus phantom, experiments show a mean error of 0.96 mm. Conclusions The designed CR is slender, flexible, and able to smoothly approach the target in a tortuous and constrained environment without colliding with or damaging the surrounding tissue. The designed continuum robotic system and the proposed iterative Jacobian transpose-based closed-loop control strategy have great potential for MSS. The limitations of the proposed method are also discussed.
- 29 December 2022
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 18 (4) , 753-761
Design and path tracking control of a continuum robot for maxillary sinus surgery
Purpose Continuum robots (CRs) have been developed for maxillary sinus surgery (MSS) in recent years. However, due to the anatomically curved and narrow pathway of the maxillary sinus and the deformable characteristics of the CR, it is still a challenge to accurately approach the target in the sinus. Thus, the CR-assisted MSS demands further research, whether in robotic system design or in reliable motion control. Methods A continuum robotic system integrated with essential instruments and sensors for MSS is developed, and the path tracking control of the designed CR is studied. The differential kinematic model of the CR is constructed. By analyzing the potential problem of the traditional Jacobian-based control, an iterative Jacobian transpose-based closed-loop control method is proposed to improve the path tracking performance. To validate the design of the CR and the effectiveness of the proposed control scheme, different groups of experiments are performed. Results With the proposed method, the path tracking performance of the CR is improved. Compared with the open-loop Jacobian transpose-based control method, the path tracking error of the proposed method is much less. The maxillary sinus phantom tests are conducted to verify the reachability of the designed CR. Given the reference path from the nostril to the target in the maxillary sinus phantom, experiments show a mean error of 0.96 mm. Conclusions The designed CR is slender, flexible, and able to smoothly approach the target in a tortuous and constrained environment without colliding with or damaging the surrounding tissue. The designed continuum robotic system and the proposed iterative Jacobian transpose-based closed-loop control strategy have great potential for MSS. The limitations of the proposed method are also discussed.
- 21 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 28 (2) , 715-725
Spatial Shape Sensing of a Multisection Continuum Robot With Integrated DTG Sensor for Maxillary Sinus Surgery
Owing to the curved and narrow pathway of the maxillary sinus, reaching blind regions using rigid instruments in the traditional method of treatment is difficult. In this article, a novel multisection continuum robot (CR) integrated with essential instruments and sensors is developed for the maxillary sinus surgery. Moreover, shape sensing is important for the control of the CR, but this is still a challenge due to the confined operating space. To track the spatial shape of the developed CR, a draw tower grating (DTG) sensor is integrated. A shape sensing algorithm is proposed to reconstruct the shape of the CR based on the relation between the DTG sensor and the CR centerline. Simulations and experiments on a maxillary sinus phantom are conducted to test the ability of the CR to reach the blind regions. Different groups of experiments are performed to evaluate the performance of the shape reconstructions, including DTG sensor shape tests and CR shape tests in planar and spatial space. Experiments show a mean planar error of 0.23 mm (0.51%) and a mean spatial error of 0.61 mm (1.36%). The results demonstrate the effectiveness of the multisection CR shape sensing method suggested in this study.
- 21 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 28 (2) , 715-725
Spatial Shape Sensing of a Multisection Continuum Robot With Integrated DTG Sensor for Maxillary Sinus Surgery
Owing to the curved and narrow pathway of the maxillary sinus, reaching blind regions using rigid instruments in the traditional method of treatment is difficult. In this article, a novel multisection continuum robot (CR) integrated with essential instruments and sensors is developed for the maxillary sinus surgery. Moreover, shape sensing is important for the control of the CR, but this is still a challenge due to the confined operating space. To track the spatial shape of the developed CR, a draw tower grating (DTG) sensor is integrated. A shape sensing algorithm is proposed to reconstruct the shape of the CR based on the relation between the DTG sensor and the CR centerline. Simulations and experiments on a maxillary sinus phantom are conducted to test the ability of the CR to reach the blind regions. Different groups of experiments are performed to evaluate the performance of the shape reconstructions, including DTG sensor shape tests and CR shape tests in planar and spatial space. Experiments show a mean planar error of 0.23 mm (0.51%) and a mean spatial error of 0.61 mm (1.36%). The results demonstrate the effectiveness of the multisection CR shape sensing method suggested in this study.
- 12 September 2022
- Published by ASME International in Journal of Mechanisms and Robotics
- Vol. 14 (6)
Closed-Loop Trajectory Tracking Control of a Cable-Driven Continuum Robot With Integrated Draw Tower Grating Sensor Feedback
Due to the inherent deformability of continuum robots (CRs), closed-loop control strategies of CRs come with some challenges, including sensor integration within a limited dimension and uncertainties with the CR system. In this paper, to obtain the spatial shape information and tip position of a cable-driven CR, a draw tower grating (DTG) sensor is integrated. A shape sensing algorithm is proposed to reconstruct the shape of the CR based on the relation between the DTG sensor and the CR centerline. Then, with the feedback information of the DTG sensor, a damped least-squares (DLS)-based closed-loop controller is implemented to improve the trajectory tracking performance of the CR. To verify the effectiveness of the proposed scheme, comparative experiments are performed.
- 12 September 2022
- Published by ASME International in Journal of Mechanisms and Robotics
- Vol. 14 (6)
Closed-Loop Trajectory Tracking Control of a Cable-Driven Continuum Robot With Integrated Draw Tower Grating Sensor Feedback
Due to the inherent deformability of continuum robots (CRs), closed-loop control strategies of CRs come with some challenges, including sensor integration within a limited dimension and uncertainties with the CR system. In this paper, to obtain the spatial shape information and tip position of a cable-driven CR, a draw tower grating (DTG) sensor is integrated. A shape sensing algorithm is proposed to reconstruct the shape of the CR based on the relation between the DTG sensor and the CR centerline. Then, with the feedback information of the DTG sensor, a damped least-squares (DLS)-based closed-loop controller is implemented to improve the trajectory tracking performance of the CR. To verify the effectiveness of the proposed scheme, comparative experiments are performed.
- 18 May 2022
- Published by SAGE Publications in Journal of X-Ray Science and Technology
- Vol. 30 (4) , 835-846
Evaluating image quality and optimal parameters for non-linear blending dual-energy computed tomography images of hepatic portal veins by blending-property-map
BACKGROUND: Blending technology is usually used to improve quality of dual-energy computed (DECT) images. OBJECTIVES: To evaluate the blended DECT image qualities by employing the Blending-Property-Map (BP-Map) and elucidating the optimal parameters with the highest signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). METHODS: Sixty pairs of 80 kV and 140 kV CT images are blended non-linearly by four methods. Protocol A uses the fixed values of blending width (BW) and blending center (BC); Protocol B uses the values of BW = (CThepatic portal vein – CThepatic parenchymal) / 2 and BC = (CThepatic portal vein + CThepatic parenchymal) / 2; Protocol C uses a BW ranging from 10 to 100 HU at an interval of 10 HU and BC = (CThepatic portal vein + CThepatic parenchymal) / 2; Protocol D uses the BP-Map that covers all possible values of BW and BC. RESULTS: When using CT value of adipose tissue as noise, the calculated SNR and CNR of optimal blending width and blending center were 123.22±41.73 and 9.00±3.52, respectively, by the BP-Map in the protocol D. By employing the CT value of back muscle as noise, the SNR and CNR of the best-blended images were 75.90±14.52 and 6.39±2.37, respectively. The subjective score of protocol D was 4.88±0.12. CONCLUSIONS: Compared to traditional blending methods, the BP-Map technique can determine the optimal blending parameter and provide the best-blended images with the highest SNR and CNR.
- 18 May 2022
- Published by SAGE Publications in Journal of X-Ray Science and Technology
- Vol. 30 (4) , 835-846
Evaluating image quality and optimal parameters for non-linear blending dual-energy computed tomography images of hepatic portal veins by blending-property-map
BACKGROUND: Blending technology is usually used to improve quality of dual-energy computed (DECT) images. OBJECTIVES: To evaluate the blended DECT image qualities by employing the Blending-Property-Map (BP-Map) and elucidating the optimal parameters with the highest signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). METHODS: Sixty pairs of 80 kV and 140 kV CT images are blended non-linearly by four methods. Protocol A uses the fixed values of blending width (BW) and blending center (BC); Protocol B uses the values of BW = (CThepatic portal vein – CThepatic parenchymal) / 2 and BC = (CThepatic portal vein + CThepatic parenchymal) / 2; Protocol C uses a BW ranging from 10 to 100 HU at an interval of 10 HU and BC = (CThepatic portal vein + CThepatic parenchymal) / 2; Protocol D uses the BP-Map that covers all possible values of BW and BC. RESULTS: When using CT value of adipose tissue as noise, the calculated SNR and CNR of optimal blending width and blending center were 123.22±41.73 and 9.00±3.52, respectively, by the BP-Map in the protocol D. By employing the CT value of back muscle as noise, the SNR and CNR of the best-blended images were 75.90±14.52 and 6.39±2.37, respectively. The subjective score of protocol D was 4.88±0.12. CONCLUSIONS: Compared to traditional blending methods, the BP-Map technique can determine the optimal blending parameter and provide the best-blended images with the highest SNR and CNR.
- 11 October 2021
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 18 (1) , e2340
Development and validation of a two‐segment continuum robot for maxillary sinus surgery
Background: Existing rigid instruments have difficulties in backward inspection and operation. Moreover, the pathway to the maxillary sinus is curved and narrow, resulting in complex and repetitive manual operations. There is a necessity to develop a retro‐flexing robot and achieve path‐following motion.Methods: A continuum robotic system is developed for maxillary sinus surgery (MSS). And the system adopts an anatomical constraint‐based optimization of the follow‐the‐leader strategy to generate a safe control scheme along a given path.Results: The accuracy of the system is evaluated, and the task of reaching deep‐seated targets is performed in a constrained anatomical space. The simulations and experiments of the path‐following motion have validated the feasibility of the proposed method. Furthermore, a preliminary porcine study is performed to assess the capability of instruments.Conclusions: The developed continuum robotic system can meet the requirements of MSS.
- 11 October 2021
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 18 (1) , e2340
Development and validation of a two‐segment continuum robot for maxillary sinus surgery
Background: Existing rigid instruments have difficulties in backward inspection and operation. Moreover, the pathway to the maxillary sinus is curved and narrow, resulting in complex and repetitive manual operations. There is a necessity to develop a retro‐flexing robot and achieve path‐following motion.Methods: A continuum robotic system is developed for maxillary sinus surgery (MSS). And the system adopts an anatomical constraint‐based optimization of the follow‐the‐leader strategy to generate a safe control scheme along a given path.Results: The accuracy of the system is evaluated, and the task of reaching deep‐seated targets is performed in a constrained anatomical space. The simulations and experiments of the path‐following motion have validated the feasibility of the proposed method. Furthermore, a preliminary porcine study is performed to assess the capability of instruments.Conclusions: The developed continuum robotic system can meet the requirements of MSS.
- Open Access
- 1 April 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1187 (3) , 032076
Research on Trajectory Tracking and Vibration Suppression of a Smart Flexible-joint-and-link Space Manipulator
The under actuated model of a smart space manipulator with flexible links and joints is established based on the Lagrange equation and assumed model method. Afterwards, using singular perturbation method, the system is decomposed into a slow subsystem and a fast subsystem, which describe the rigid-body motion and flexible vibration, respectively. Then, a modified computed torque controller based on the under actuated model is put forward to realize trajectory tracking of joints. In the meantime, the joint flexibility is compensated real-timely by the motors while the real-time suppression of the link vibration is realized by the embedded piezoelectric actuators. Finally, the simulation results indicate that the proposed composite control strategy can realize the trajectory tracking rapidly and in the same time suppress the vibration caused by flexible joints and links efficiently.
- 1 April 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1187 (3) , 032076
Open AccessResearch on Trajectory Tracking and Vibration Suppression of a Smart Flexible-joint-and-link Space Manipulator
The under actuated model of a smart space manipulator with flexible links and joints is established based on the Lagrange equation and assumed model method. Afterwards, using singular perturbation method, the system is decomposed into a slow subsystem and a fast subsystem, which describe the rigid-body motion and flexible vibration, respectively. Then, a modified computed torque controller based on the under actuated model is put forward to realize trajectory tracking of joints. In the meantime, the joint flexibility is compensated real-timely by the motors while the real-time suppression of the link vibration is realized by the embedded piezoelectric actuators. Finally, the simulation results indicate that the proposed composite control strategy can realize the trajectory tracking rapidly and in the same time suppress the vibration caused by flexible joints and links efficiently.