Identifying Noisy Electrodes in High Density Surface Electromyography Recordings Through Analysis of Spatial Similarities
- 1 July 2018
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2018, 2325-2328
Abstract
In this study we developed a technique for identifying noisy electrodes in high density surface electromyography (HD-sEMG). The technique finds the spatial similarity of each electrode in the electrode array by counting the number of interactions the electrode has. Using this information the technique identifies noisy electrodes by finding electrodes that are significantly dissimilar to the other electrodes. The HD-sEMG recordings used in this study were taken from three participants who performed two isometric contractions of their biceps at 40% and 80% of their maximum voluntary contraction (MVC) force. White Gaussian noisy was added to a varying number of recorded signals before being digital filtering to generate a variety of recordings to test the technique with. In the recordings, groups of 2, 4, 8, and 16 electrodes had noise added such that the signal to noise ratios (SNR) were 0, 5, 10, 15, and 20dB. The results show that the technique can reliably identify groups of 2, 4, and 8 noisy electrodes with SNRs of 0, 5, and 10dB.Keywords
This publication has 12 references indexed in Scilit:
- Measuring the interactions between different locations in a muscle to monitor localized muscle fatigue2017
- Estimating the progression of muscle fatigue based on dependence between motor units using high density surface electromyogram2016
- Automated Biosignal Quality Analysis for Electromyography Using a One-Class Support Vector MachineIEEE Transactions on Instrumentation and Measurement, 2014
- Outlier detection in high-density surface electromyographic signalsMedical & Biological Engineering & Computing, 2011
- On-line signal quality estimation of multichannel surface electromyogramsMedical & Biological Engineering & Computing, 2005
- Evolution in impedance at the electrode-skin interface of two types of surface EMG electrodes during long-term recordingsJournal of Electromyography and Kinesiology, 2003
- Investigation into the origin of the noise of surface electrodesMedical & Biological Engineering & Computing, 2002
- Sampling, noise-reduction and amplitude estimation issues in surface electromyographyJournal of Electromyography and Kinesiology, 2002
- A direct comparison of wet, dry and insulating bioelectric recording electrodesPhysiological Measurement, 2000
- Temporal changes in electrode impedance while recording the electrocardiogram with “Dry” electrodesAnnals of Biomedical Engineering, 1973