Experimental spectral measurements of heavyK-edge filtered beams for x-ray computed mammotomography
Authors:
- 10 January 2007
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 52 (3) , 603-616
Abstract
A dual modality computed mammotomography (CmT) and single photon emission computed tomography (SPECT) system for dedicated 3D breast imaging is in development. Using heavy K-edge filtration, the CmT component narrows the energy spectrum of the cone-shaped x-ray beam incident on the patient's pendant, uncompressed breast. This quasi-monochromatic beam is expected to improve discrimination of tissue with similar attenuation coefficients while restraining absorbed dose to below that of dual view mammography. Previous simulation studies showed the optimal energy that maximizes dose efficiency for a 50/50% adipose/glandular breast is between 30 and 40 keV. This study experimentally validates these results using pre-breast and post-breast spectral measurements made under tungsten tube voltages between 40 and 100 kVp using filter materials with K-edge values ranging from 15 to 70 keV. Different filter material thicknesses are used, approximately equivalent to the 200th and 500th attenuating value layer (VL) thickness. Cerium (K = 40.4 keV) filtered post-breast spectra for 8-18 cm breasts are measured for a range of breast compositions. Figures of merit include mean beam energy, spectral full-width at tenth-maximum, beam hardening and dose for the range of breast sizes. Measurements corroborate simulation results, indicating that for a given dose, a 200th VL of cerium filtration may have optimal performance in the dedicated mammotomography paradigm.Keywords
This publication has 11 references indexed in Scilit:
- Compton‐scattering measurement of diagnostic x‐ray spectrum using high‐resolution Schottky CdTe detectorMedical Physics, 2005
- Development of an optimal X-ray beam for dual-mode emission and transmission mammotomographyNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2004
- Simulation study of a quasi‐monochromatic beam for x‐ray computed mammotomographyMedical Physics, 2004
- A comprehensive analysis of DgNCT coefficients for pendant-geometry cone-beam breast computed tomographyMedical Physics, 2004
- Radiography of soft tissue of the foot and ankle with diffraction enhanced imagingJournal of Anatomy, 2003
- Cone‐beam volume CT breast imaging: Feasibility studyMedical Physics, 2002
- An iterative maximum-likelihood polychromatic algorithm for CTIEEE Transactions on Medical Imaging, 2001
- Bragg-diffraction-based quasi-monochromatic source for mammography using mosaic crystals1999
- Diffraction enhanced x-ray imagingPhysics in Medicine & Biology, 1997
- Absorbed Radiation Dose in MammographyRadiology, 1979