Dominic J. Crotty
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Dominic J. Crotty has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
M P Tornai
Department of Radiology, Duke University Medical Center, Durham, NC 27710, USA
1 shared publicationMartin P. Tornai
Senior Member, IEEE, Member, IEEE, Multi-Modality Imaging Laboratory, departments of Radiology, Biomedical Engineering, Medical Physics Graduate Program, Duke University, Durham, NC 27710 USA. telephone: 919-684-7943
1 shared publication- Martin P. Tornai
Duke University
1 shared publication Priti Madhav
Member, IEEE, Member, IEEE, Multi-Modality Imaging Laboratory, departments of Radiology, Biomedical Engineering, Medical Physics Graduate Program, Duke University, Durham, NC 27710 USA. telephone: 919-684-7943
1 shared publicationR L McKinley
Department of Radiology, Duke University Medical Center, Durham, NC 27710, USA
1 shared publicationRandolph L. McKinley
Member, IEEE, Member, IEEE, Multi-Modality Imaging Laboratory, departments of Radiology, Biomedical Engineering, Medical Physics Graduate Program, Duke University, Durham, NC 27710 USA. telephone: 919-684-7943
1 shared publication
Latest Publications
- 10 January 2007
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 52 (3) , 603-616
Experimental spectral measurements of heavyK-edge filtered beams for x-ray computed mammotomography
A dual modality computed mammotomography (CmT) and single photon emission computed tomography (SPECT) system for dedicated 3D breast imaging is in development. Using heavy K-edge filtration, the CmT component narrows the energy spectrum of the cone-shaped x-ray beam incident on the patient's pendant, uncompressed breast. This quasi-monochromatic beam is expected to improve discrimination of tissue with similar attenuation coefficients while restraining absorbed dose to below that of dual view mammography. Previous simulation studies showed the optimal energy that maximizes dose efficiency for a 50/50% adipose/glandular breast is between 30 and 40 keV. This study experimentally validates these results using pre-breast and post-breast spectral measurements made under tungsten tube voltages between 40 and 100 kVp using filter materials with K-edge values ranging from 15 to 70 keV. Different filter material thicknesses are used, approximately equivalent to the 200th and 500th attenuating value layer (VL) thickness. Cerium (K = 40.4 keV) filtered post-breast spectra for 8-18 cm breasts are measured for a range of breast compositions. Figures of merit include mean beam energy, spectral full-width at tenth-maximum, beam hardening and dose for the range of breast sizes. Measurements corroborate simulation results, indicating that for a given dose, a 200th VL of cerium filtration may have optimal performance in the dedicated mammotomography paradigm.
- 10 January 2007
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 52 (3) , 603-616
Experimental spectral measurements of heavyK-edge filtered beams for x-ray computed mammotomography
A dual modality computed mammotomography (CmT) and single photon emission computed tomography (SPECT) system for dedicated 3D breast imaging is in development. Using heavy K-edge filtration, the CmT component narrows the energy spectrum of the cone-shaped x-ray beam incident on the patient's pendant, uncompressed breast. This quasi-monochromatic beam is expected to improve discrimination of tissue with similar attenuation coefficients while restraining absorbed dose to below that of dual view mammography. Previous simulation studies showed the optimal energy that maximizes dose efficiency for a 50/50% adipose/glandular breast is between 30 and 40 keV. This study experimentally validates these results using pre-breast and post-breast spectral measurements made under tungsten tube voltages between 40 and 100 kVp using filter materials with K-edge values ranging from 15 to 70 keV. Different filter material thicknesses are used, approximately equivalent to the 200th and 500th attenuating value layer (VL) thickness. Cerium (K = 40.4 keV) filtered post-breast spectra for 8-18 cm breasts are measured for a range of breast compositions. Figures of merit include mean beam energy, spectral full-width at tenth-maximum, beam hardening and dose for the range of breast sizes. Measurements corroborate simulation results, indicating that for a given dose, a 200th VL of cerium filtration may have optimal performance in the dedicated mammotomography paradigm.
- 2 March 2006
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6142
Experimental spectral measurements of heavy K-edge filtered beams for x-ray computed mammotomography
A compact, dual modality computed mammotomography (CmT) and single photon emission computed tomography (SPECT) system for dedicated 3D breast imaging is in development. The CmT component utilizes novel, heavy K-edge filtration to practicably narrow the energy spectrum of the cone-shaped x-ray beam incident on the patient's pendant, uncompressed breast. This quasi-monochromatic beam in CmT is expected to improve discrimination of tissue with very similar attenuation coefficients while restraining dose levels to below that of existing dual view mammography. Our previous extensive simulation studies showed the optimal energy range that provides maximum dose efficiency for a 50/50 adipose/glandular breast is in the 35-40keV range. This current study aims to experimentally validate previous simulation results. Here, experimental pre-breast and post-breast collimated x-ray beam spectral measurements are made under tube operating voltages between 40-100kVp using filter materials from Z=13-74, with K-edge values spanning that of Ce (K=40.4keV), and using different attenuating thicknesses of filter material, approximately equivalent to the 200th and 500th attenuating value layer (VL) thickness. Ce-filtered post breast spectra for 8cm to 18cm breasts are measured for a range of breast adipose/glandular compositions. Evaluated figures of merit include mean beam energy, spectral full-width at tenth-maximum, beam hardening and dose for the range of breast sizes. Measurements are shown to corroborate the simulations, and both indicate that for a given dose a 200th VL of Ce filtration may have the most optimal performance in the dedicated mammotomography paradigm.
- 2 March 2006
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6142
Experimental spectral measurements of heavy K-edge filtered beams for x-ray computed mammotomography
A compact, dual modality computed mammotomography (CmT) and single photon emission computed tomography (SPECT) system for dedicated 3D breast imaging is in development. The CmT component utilizes novel, heavy K-edge filtration to practicably narrow the energy spectrum of the cone-shaped x-ray beam incident on the patient's pendant, uncompressed breast. This quasi-monochromatic beam in CmT is expected to improve discrimination of tissue with very similar attenuation coefficients while restraining dose levels to below that of existing dual view mammography. Our previous extensive simulation studies showed the optimal energy range that provides maximum dose efficiency for a 50/50 adipose/glandular breast is in the 35-40keV range. This current study aims to experimentally validate previous simulation results. Here, experimental pre-breast and post-breast collimated x-ray beam spectral measurements are made under tube operating voltages between 40-100kVp using filter materials from Z=13-74, with K-edge values spanning that of Ce (K=40.4keV), and using different attenuating thicknesses of filter material, approximately equivalent to the 200th and 500th attenuating value layer (VL) thickness. Ce-filtered post breast spectra for 8cm to 18cm breasts are measured for a range of breast adipose/glandular compositions. Evaluated figures of merit include mean beam energy, spectral full-width at tenth-maximum, beam hardening and dose for the range of breast sizes. Measurements are shown to corroborate the simulations, and both indicate that for a given dose a 200th VL of Ce filtration may have the most optimal performance in the dedicated mammotomography paradigm.
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 6 (10823654) , 3915-3919
Patient Bed Design for an Integrated SPECT-CT Dedicated Mammotomography System
This study investigates the significant challenges and tradeoffs associated with designing a patient positioning system for a novel, compact SPECT-CT system dedicated to 3D breast and chest wall imaging. The primary challenge is to maintain patient comfort while optimally positioning the patient for maximal chest wall imaging, given the physical and geometric dimensions of the dual-modality system. The dedicated breast SPECT system comprises a 16times20cm2 CZT-based gamma camera attached to a versatile gantry, capable of varying polar tilt, radial distance and azimuth. The dedicated breast cone beam CT system, initially designed here without dynamic polar tilt, includes a tungsten target source and a 20times25cm2 CsI(Tl) detector laterally offset from the central ray, separated by a 60cm SID. The integrated imaging system with a common field-of-view is positioned below the custom-designed, 3-dimensionally flexible bed positioning system. An additional consideration of the bed is that it is radio-opaque, which minimizes both emission contamination from the patient's body into the transmission CT system, while simultaneously minimizing any X-ray scatter onto the patient's body. This preliminary implementation and investigation indicates the need for novel camera trajectories to satisfy both chest wall proximity imaging and patient comfort. The effects of breast volume imaged within the common FOV and table angles, which are assumed to correspond to patient comfort, are examined. A manufactured galvanized steel prototype demonstrates the practicability of the bed.
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 6 (10823654) , 3915-3919
Patient Bed Design for an Integrated SPECT-CT Dedicated Mammotomography System
This study investigates the significant challenges and tradeoffs associated with designing a patient positioning system for a novel, compact SPECT-CT system dedicated to 3D breast and chest wall imaging. The primary challenge is to maintain patient comfort while optimally positioning the patient for maximal chest wall imaging, given the physical and geometric dimensions of the dual-modality system. The dedicated breast SPECT system comprises a 16times20cm2 CZT-based gamma camera attached to a versatile gantry, capable of varying polar tilt, radial distance and azimuth. The dedicated breast cone beam CT system, initially designed here without dynamic polar tilt, includes a tungsten target source and a 20times25cm2 CsI(Tl) detector laterally offset from the central ray, separated by a 60cm SID. The integrated imaging system with a common field-of-view is positioned below the custom-designed, 3-dimensionally flexible bed positioning system. An additional consideration of the bed is that it is radio-opaque, which minimizes both emission contamination from the patient's body into the transmission CT system, while simultaneously minimizing any X-ray scatter onto the patient's body. This preliminary implementation and investigation indicates the need for novel camera trajectories to satisfy both chest wall proximity imaging and patient comfort. The effects of breast volume imaged within the common FOV and table angles, which are assumed to correspond to patient comfort, are examined. A manufactured galvanized steel prototype demonstrates the practicability of the bed.