In the presence of intrafraction organ motion, target localization uncertainty can greatly hamper the advantage of highly conformal dose techniques such as intensity modulated radiation therapy (IMRT). To minimize the adverse dosimetric effect caused by tumor motion, a real‐time knowledge of the tumor position is required throughout the beam delivery process. The recent integration of onboard kV diagnostic imaging together with MV electronic portal imaging devices on linear accelerators can allow for real‐time three‐dimensional (3D) tumor position monitoring during a treatment delivery. The aim of this study is to demonstrate a near real‐time 3D internal fiducial tracking system based on the combined use of kV and MV imaging. A commercially available radiotherapy system equipped with both kV and MV imaging systems was used in this work. A hardware video frame grabber was used to capture both kV and MV video streams simultaneously through independent video channels at 30 frames per second. The fiducial locations were extracted from the kV and MV images using a software tool. The geometric tracking capabilities of the system were evaluated using a pelvic phantom with embedded fiducials placed on a moveable stage. The maximum tracking speed of the kV/MV system is approximately 9 Hz, which is primarily limited by the frame rate of the MV imager. The geometric accuracy of the system is found to be on the order of less than 1 mm in all three spatial dimensions. The technique requires minimal hardware modification and is potentially useful for image‐guided radiation therapy systems.Keywords
Funding Information
- National Cancer Institute (1R01 CA98523)
- National Cancer Institute (CA104205)
This publication has 32 references indexed in Scilit:
- Individualized gating windows based on four-dimensional CT information for respiration-gated radiotherapyPhysics in Medicine & Biology, 2007
- Examination of geometric and dosimetric accuracies of gated step‐and‐shoot intensity modulated radiation therapyMedical Physics, 2007
- Fluoroscopic tracking of multiple implanted fiducial markers using multiple object trackingPhysics in Medicine & Biology, 2007
- Technical and dosimetric aspects of respiratory gating using a pressure‐sensor motion monitoring systemMedical Physics, 2005
- A four-dimensional controller for DMLC-based tumor trackingInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2004
- Errors and margins in radiotherapySeminars in Radiation Oncology, 2004
- Tracking moving organs in real timeSeminars in Radiation Oncology, 2004
- Intrafractional tumor motion: lung and liverSeminars in Radiation Oncology, 2004
- Robotic motion compensation for respiratory movement during radiosurgeryComputer Aided Surgery, 2000
- Respiration gated radiotherapy treatment: a technical studyPhysics in Medicine & Biology, 1996