Accurate, precise, simultaneous myocardial T1 and T2 mapping using a radial sequence with inversion recovery and T2 preparation
- 28 August 2019
- journal article
- research article
- Published by Wiley in NMR in Biomedicine
- Vol. 32 (11) , e4165
Abstract
We propose a simultaneous myocardial T1 and T2 mapping technique using a radial sequence with inversion recovery and T2 preparation, which achieves high accuracy and precision, with T1 and T2 reproducibility similar to the Modified Look‐Locker Inversion recovery (MOLLI) sequence and the conventional bright blood T2 mapping technique, respectively. The sequence was developed by incorporating gold angle radial fast low angle shot (FLASH) readout combined with an inversion pulse and T2prep pulses. The extended Bloch equation simulation with slice profile correction (BLESSPC) algorithm was proposed to reconstruct T1 and T2 maps at the same time in a few seconds, while maintaining good T1 and T2 estimation accuracy. Accuracy and precision were compared among the proposed technique, MOLLI and conventional T2 mapping techniques using phantom studies, 10 healthy volunteers and three patients. In phantom studies, the proposed technique was more accurate than MOLLI (P < 0.05) while achieving similar precision (P = 0.3) in T1 estimation, and was more accurate (P < 0.05) and precise (P < 0.001) than conventional T2 mapping (two‐parameter fitting) in T2 estimation. In vivo, the proposed technique achieved significantly higher T1 values (P < 0.001) and similar reproducibility (P = 0.3) compared with MOLLI, with significantly lower T2 values (P < 0.001) and similar reproducibility (P = 0.6) compared with the conventional T2 mapping technique. Thus, the proposed radial T1‐T2 mapping technique allows for accurate, precise, simultaneous myocardial T1 and T2 mapping in an 11‐heartbeat single breath‐hold acquisition.Keywords
Funding Information
- National Heart, Lung, and Blood Institute (R01HL127153)
This publication has 41 references indexed in Scilit:
- T 1 measurements in the human myocardium: The effects of magnetization transfer on the SASHA and MOLLI sequencesMagnetic Resonance in Medicine, 2013
- Noncontrast T1 Mapping for the Diagnosis of Cardiac AmyloidosisJACC: Cardiovascular Imaging, 2013
- T1 and extracellular volume mapping in the heart: estimation of error maps and the influence of noise on precisionJournal of Cardiovascular Magnetic Resonance, 2013
- Modified Look‐Locker T1 evaluation using Bloch simulations: Human and phantom validationMagnetic Resonance in Medicine, 2012
- Non-contrast T1-mapping detects acute myocardial edema with high diagnostic accuracy: a comparison to T2-weighted cardiovascular magnetic resonanceJournal of Cardiovascular Magnetic Resonance, 2012
- Assessment of Myocardial Fibrosis With Cardiovascular Magnetic ResonanceJACC, 2011
- Shortened Modified Look-Locker Inversion recovery (ShMOLLI) for clinical myocardial T1-mapping at 1.5 and 3 T within a 9 heartbeat breathholdJournal of Cardiovascular Magnetic Resonance, 2010
- T2 quantification for improved detection of myocardial edemaJournal of Cardiovascular Magnetic Resonance, 2009
- T2 measurement of the human myocardium using a T2‐prepared transient‐state trueFISP sequenceMagnetic Resonance in Medicine, 2007
- Modified Look‐Locker inversion recovery (MOLLI) for high‐resolution T1 mapping of the heartMagnetic Resonance in Medicine, 2004