  • Ferumoxytol‐enhanced magnetic resonance T1 reactivity for depiction of myocardial hypoperfusion

    by Caroline M. Colbert, Anna H. Le, Jiaxin Shao, Jesse W. Currier, Olujimi A. Ajijola, Peng Hu, Kim‐Lien Nguyen

    Myocardial T1 reactivity, defined as the relative change in T1 between rest and vasodilator‐induced stress, has been proposed as a magnetic resonance imaging (MRI) biomarker of tissue perfusion. We hypothesize that the superparamagnetic iron‐oxide nanoparticle, ferumoxytol, sensitizes T1 to changes in the intramyocardial vascular compartment and improves the sensitivity and specificity of T1 reactivity as an imaging biomarker of tissue perfusion. We aim to assess the diagnostic performance of ferumoxytol‐enhanced (FE) myocardial T1 reactivity in swine models of myocardial hypoperfusion. We induced acute myocardial hypoperfusion in 13 swine via percutaneous, transcatheter deployment of a 3D printed intracoronary stenosis implant into the left anterior descending coronary artery. We performed native and FE adenosine stress testing using 5(3)3(3)3 MOLLI and SASHA T1 mapping sequences with bSSFP readout on a clinical 3.0 T magnet. MOLLI T1 maps were fitted using both the conventional MOLLI and the Instantaneous Signal Loss (InSiL) T1‐fitting algorithms. Regardless of the MOLLI or SASHA pulse sequence or T1‐fitting algorithm, ferumoxytol contrast increased the dynamic range of T1 reactivity in both the remote and ischemic myocardial regions. Relative to remote myocardium, native and FE T1 reactivity were blunted in ischemic myocardium (p < 0.05) with InSiL‐MOLLI, MOLLI and SASHA. An InSiL‐MOLLI–derived FE T1 reactivity threshold of −4.65% had 73.3% sensitivity and 96.2% specificity for prediction of regional wall motion abnormalities (AUC 0.915, 95% CI 0.786–0.979), whereas a SASHA‐derived FE T1 reactivity threshold of −5.25% had 75.0% sensitivity and 95.2% specificity (AUC 0.905, 95% CI 0.751–0.979). Ferumoxytol significantly increased the dynamic range of T1 reactivity as a measure of myocardial hypoperfusion in vasodilator stress T1 mapping studies. FE T1 reactivity maps can be used to quantitatively distinguish ischemic and remote myocardium with high specificity in swine models of acute myocardial hypoperfusion.


  • Fast and accurate calculation of myocardial T1 and T2 values using deep learning Bloch equation simulations (DeepBLESS)

    by Jiaxin Shao, Vahid Ghodrati, Kim‐Lien Nguyen, Peng Hu

    Purpose: To propose and evaluate a deep learning model for rapid and accurate calculation of myocardial T1/T2 values based on a previously proposed Bloch equation simulation with slice profile correction (BLESSPC) method.Methods: Deep learning Bloch equation simulations (DeepBLESS) models are proposed for rapid and accurate T1 estimation for the MOLLI T1 mapping sequence with balanced SSFP readouts and T1/T2 estimation for a radial simultaneous T1 and T2 mapping (radial T1‐T2) sequence. The DeepBLESS models were trained separately based on simulated radial T1‐T2 and MOLLI data, respectively. The DeepBLESS T1‐T2 estimation accuracy was evaluated based on simulated data with different noise levels. The DeepBLESS model was compared with BLESSPC in simulation, phantom, and in vivo studies for the MOLLI sequence at 1.5 T and radial T1‐T2 sequence at 3 T.Results: After DeepBLESS was trained, in phantom studies, DeepBLESS and BLESSPC achieved similar accuracy and precision in T1‐T2 estimations for both MOLLI and radial T1‐T2 (P > .05). For in vivo, DeepBLESS and BLESSPC generated similar myocardial T1/T2 values for radial T1‐T2 at 3 T (T1: 1366 ± 31 ms for both methods, P > .05; T2: 37.4 ms ± 0.9 ms for both methods, P > .05), and similar myocardial T1 values for the MOLLI sequence at 1.5 T (1044 ± 20 ms for both methods, P > .05). DeepBLESS generated a T1/T2 map in less than 1 second.Conclusion: The DeepBLESS model offers an almost instantaneous approach for estimating accurate T1/T2 values, replacing BLESSPC for both MOLLI and radial T1‐T2 sequences, and is promising for multiparametric mapping in cardiac MRI.


  • Accurate, precise, simultaneous myocardial T1 and T2 mapping using a radial sequence with inversion recovery and T2 preparation

    by Jiaxin Shao, Ziwu Zhou, Kim‐Lien Nguyen, J. Paul Finn, Peng Hu

    We propose a simultaneous myocardial T1 and T2 mapping technique using a radial sequence with inversion recovery and T2 preparation, which achieves high accuracy and precision, with T1 and T2 reproducibility similar to the Modified Look‐Locker Inversion recovery (MOLLI) sequence and the conventional bright blood T2 mapping technique, respectively. The sequence was developed by incorporating gold angle radial fast low angle shot (FLASH) readout combined with an inversion pulse and T2prep pulses. The extended Bloch equation simulation with slice profile correction (BLESSPC) algorithm was proposed to reconstruct T1 and T2 maps at the same time in a few seconds, while maintaining good T1 and T2 estimation accuracy. Accuracy and precision were compared among the proposed technique, MOLLI and conventional T2 mapping techniques using phantom studies, 10 healthy volunteers and three patients. In phantom studies, the proposed technique was more accurate than MOLLI (P < 0.05) while achieving similar precision (P = 0.3) in T1 estimation, and was more accurate (P < 0.05) and precise (P < 0.001) than conventional T2 mapping (two‐parameter fitting) in T2 estimation. In vivo, the proposed technique achieved significantly higher T1 values (P < 0.001) and similar reproducibility (P = 0.3) compared with MOLLI, with significantly lower T2 values (P < 0.001) and similar reproducibility (P = 0.6) compared with the conventional T2 mapping technique. Thus, the proposed radial T1‐T2 mapping technique allows for accurate, precise, simultaneous myocardial T1 and T2 mapping in an 11‐heartbeat single breath‐hold acquisition.


  • Accuracy, precision, and reproducibility of myocardial T1 mapping: A comparison of four T1 estimation algorithms for modified look‐locker inversion recovery (MOLLI)

    by Jiaxin Shao, Dapeng Liu, Kyunghyun Sung, Kim‐Lien Nguyen, Peng Hu

    Purpose: To compare the accuracy and precision of four different T1 estimation algorithms for modified Look‐Locker inversion recovery (MOLLI).Methods: Four T1 estimation algorithms, including the original fit, inversion group (IG) fit, instantaneous signal loss simulation (InSiL), and Bloch equation simulation with slice profile correction (BLESSPC) were studied. T1 estimation accuracy, precision, reproducibility, and sensitivity to heart rate (HR), flip angle (FA), and acquisition scheme (AcS) variations were compared in simulation, phantom, and volunteer studies.Results: T1 estimation accuracy of IG (‐2.4% ± 3.9%) and original fit (‐3.2% ± 1.4%) were worse than BLESSPC (0.2% ± 1.5%) and InSiL (‐0.7% ± 2.1%). The original fit had the best precision for T1 from 409–1884 ms for the same FA (0.67% ± 0.16% versus 0.90% ± 0.23% using IG, 0.78% ± 0.11% using InSiL, 0.77% ± 0.12% using BLESSPC). BLESSPC generated the most consistent in vivo T1 values over different FAs and AcS, and the T1 estimation reproducibility was similar (P > 0.3) among the four methods when FA = 35°. When using FA = 50°, the reproducibility was significantly improved only when using BLESSPC (1.6% ± 0.9 versus 2.6% ± 1.9%, P < 0.05).Conclusion: BLESSPC has superior accuracy and is the least sensitive to FA, HR, and AcS variations. T1 estimation using BLESSPC and FA = 50° is superior to conventional MOLLI with FA = 35° in accuracy and precision. Further clinical studies in varying pathological conditions are warranted to confirm our findings. Magn Reson Med 78:1746–1756, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


  • Phase‐contrast MRI with hybrid one and two‐sided flow‐encoding and velocity spectrum separation

    by Da Wang, Jiaxin Shao, Daniel B. Ennis, Peng Hu

    Purpose: To develop and evaluate a phase‐contrast MRI (PC‐MRI) technique with hybrid one and two‐sided flow‐encoding and velocity spectrum separation (HOTSPA) for accelerated blood flow and velocity measurement.Methods: In the HOTSPA technique, the two‐sided flow encoding (FE) is used for two FE directions and one‐sided is used for the remaining FE direction. Such a temporal modulation of the FE strategy allows for separations of the Fourier velocity spectrum into components for the flow‐compensated and the three‐directional velocity waveforms, accelerating PC‐MRI by encoding three‐directional velocities using only two repetition times (TRs) instead of four TRs as in standard PC‐MRI. The HOTSPA was evaluated and compared with standard PC‐MRI in the common carotid arteries of six healthy volunteers.Results: Total volumetric flow and peak velocity measurements based on HOTSPA and the conventional PC‐MRI were in good agreement with a bias of −0.005 mL (−0.1% relative bias error) for total volumetric flow and 1.21 cm/s (1.1% relative bias error) for peak velocity, although the total acquisition time was 50% of the conventional PC‐MRI.Conclusion: The proposed HOTSPA technique achieved nearly two‐fold acceleration of PC‐MRI while maintaining accuracy for total volumetric flow and peak velocity quantification by separating the paired acquisitions in the Fourier velocity spectrum domain. Magn Reson Med 78:182–192, 2017. © 2016 International Society for Magnetic Resonance in Medicine


  • Cardiac MRI: a Translational Imaging Tool for Characterizing Anthracycline-Induced Myocardial Remodeling

    by Kim-Lien Nguyen, Peng Hu, Daniel B. Ennis, Jiaxin Shao, Kimberly A. Pham, Joseph J. Chen

    Cardiovascular side effects of cancer therapeutics are the leading causes of morbidity and mortality in cancer survivors. Anthracyclines (AC) serve as the backbone of many anti-cancer treatment strategies, but dose-dependent myocardial injury limits their use. Cumulative AC exposure can disrupt the dynamic equilibrium of the myocardial microarchitecture while repeated injury and repair leads to myocyte loss, interstitial myocardial fibrosis, and impaired contractility. Although children are assumed to have greater myocardial plasticity, AC exposure at a younger age portends worse prognosis. In older patients, there is lower overall survival once they develop cardiovascular disease. Because aberrations in the myocardial architecture predispose the heart to a decline in function, early detection with sensitive imaging tools is crucial and the implications for resource utilization are substantial. As a comprehensive imaging modality, cardiac magnetic resonance (CMR) imaging is able to go beyond quantification of ejection fraction and myocardial deformation to characterize adaptive microstructural and microvascular changes that are important to myocardial tissue health. Herein, we describe CMR as an established translational imaging tool that can be used clinically to characterize AC-associated myocardial remodeling.


  • Myocardial T1 mapping for patients with implanted cardiac devices using wideband inversion recovery spoiled gradient echo readout

    by Jiaxin Shao, Shams Rashid, Pierangelo Renella, Kim-Lien Nguyen, Peng Hu

    Purpose To develop and validate a technique for myocardial T1 mapping in patients with implantable cardioverter defibrillators (ICDs). Methods A MOLLI-based pulse sequence, named Wideband-FLASH-MOLLI, was developed by incorporating a fast low angle shot (FLASH) readout and a wideband inversion pulse. The performance of Wideband-FLASH-MOLLI was evaluated using phantom studies and validated in eight healthy volunteers and ten patients with ICDs at 1.5 Tesla. Comparisons were made between Wideband-FLASH-MOLLI, FLASH-MOLLI, and bSSFP-MOLLI sequences. Results In phantom studies, the maximum T1 estimation errors using Wideband-FLASH-MOLLI with and without an ICD were less than 3% for T1 range from 212 to 1673 ms. In all healthy volunteers, there was no significant native myocardial T1 estimation difference using Wideband-FLASH-MOLLI before and after the external attachment of an ICD to the body coil (1178 ± 27 ms versus 1174 ± 33 ms; P = 0.41). Due to the presence of an ICD, the magnitude images acquired using bSSFP-MOLLI and FLASH-MOLLI showed severe artifacts within the myocardium. In contrast, no or negligible device-induced artifacts were noted within the myocardial regions of the healthy volunteers or the patients with ICDs when using Wideband-FLASH-MOLLI. Conclusion This study demonstrates the feasibility of using Wideband-FLASH-MOLLI to mitigate image artifacts and to produce accurate myocardial T1 maps in patients with ICDs. Magn Reson Med 77:1495–1504, 2017. © 2016 International Society for Magnetic Resonance in Medicine


  • Open Access

    Improved myocardial T1 mapping for patients with implanted cardiac devices

    by Jiaxin Shao, Shams Rashid, Kim-Lien Nguyen, Peng Hu

  • Myocardial T1 mapping at 3.0 tesla using an inversion recovery spoiled gradient echo readout and bloch equation simulation with slice profile correction (BLESSPC) T1 estimation algorithm

    by Jiaxin Shao, Stanislas Rapacchi, Kim‐Lien Nguyen, Peng Hu

    Background: To develop an accurate and precise myocardial T1 mapping technique using an inversion recovery spoiled gradient echo readout at 3.0 Tesla (T).Theory and Methods: The modified Look‐Locker inversion‐recovery (MOLLI) sequence was modified to use fast low angle shot (FLASH) readout, incorporating a BLESSPC (Bloch Equation Simulation with Slice Profile Correction) T1 estimation algorithm, for accurate myocardial T1 mapping. The FLASH‐MOLLI with BLESSPC fitting was compared with different approaches and sequences with regards to T1 estimation accuracy, precision and image artifact based on simulation, phantom studies, and in vivo studies of 10 healthy volunteers and three patients at 3.0 Tesla.Results: The FLASH‐MOLLI with BLESSPC fitting yields accurate T1 estimation (average error = −5.4 ± 15.1 ms, percentage error = −0.5% ± 1.2%) for T1 from 236–1852 ms and heart rate from 40–100 bpm in phantom studies. The FLASH‐MOLLI sequence prevented off‐resonance artifacts in all 10 healthy volunteers at 3.0T. In vivo, there was no significant difference between FLASH‐MOLLI‐derived myocardial T1 values and “ShMOLLI+IE” derived values (1458.9 ± 20.9 ms versus 1464.1 ± 6.8 ms, P = 0.50); However, the average precision by FLASH‐MOLLI was significantly better than that generated by “ShMOLLI+IE” (1.84 ± 0.36% variance versus 3.57 ± 0.94%, P < 0.001).Conclusion: The FLASH‐MOLLI with BLESSPC fitting yields accurate and precise T1 estimation, and eliminates banding artifacts associated with bSSFP at 3.0T. J. Magn. Reson. Imaging 2016;43:414–425.