Novel high‐resolution silicon drift detectors
Authors:
- 29 January 2004
- journal article
- conference paper
- Published by Wiley in X-Ray Spectrometry
- Vol. 33 (4) , 256-261
Abstract
Silicon drift detectors (SDDs) are used as energy‐dispersive detectors for x‐ray fluorescence analysis in commercial systems. Because of the low capacitance of the readout anode, achieved by the device topology and by the integration of the first FET on the chip, noise contributions are very small, allowing good energy resolution at low shaping times and high count rates. Typical energy resolution is better than 147 eV FWHM at 5.9 keV (Mn Kα), at −10°C. This allows the chips to be cooled with a thermoelectric element, avoiding the use of liquid nitrogen. SDD chips are produced at MPI‐Halbleiterlabor in Munich with different geometries and areas. Recently, a new SDD has been developed which places the anode and the integrated JFET at the margin of the chip where it can easily be shielded from direct irradiation with the use of a collimator. The new layout allows the design of a readout anode with smaller area and therefore reduces the capacitance to values of about 120 fF compared with 200–250 fF with standard SDDs. The result is an improvement in energy resolution down to 128 eV at −15°C. A second effect is the enhancement of the peak‐to‐background values to 6000 homogeneously across the active area of the detector. Copyright © 2004 John Wiley & Sons, Ltd.Keywords
This publication has 10 references indexed in Scilit:
- Handbook of X-Ray Spectrometry2001
- Silicon drift detectors for high count rate X-ray spectroscopy at room temperatureNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2001
- Room-temperature x- and gamma-ray spectroscopy with silicon drift detectors2000
- Works of art investigation with silicon drift detectorsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2000
- Continuous charge restoration in semiconductor detectors by means of the gate-to-drain current of the integrated front-end JFETIEEE Transactions on Nuclear Science, 1999
- High-Resolution X-ray Spectroscopy Close to Room TemperatureMicroscopy and Microanalysis, 1998
- Silicon drift detectors for high resolution room temperature X-ray spectroscopyNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1996
- High Resolution Silicon Detectors for Photons and ParticlesRadiation Protection Dosimetry, 1995
- Room temperature, high-resolution X-ray spectroscopy with silicon drift chambersIEEE Transactions on Nuclear Science, 1995
- Semiconductor drift chamber — An application of a novel charge transport schemeNuclear Instruments and Methods in Physics Research, 1984