Differences in pulse rate variability with measurement site
Open Access
- 21 February 2020
- journal article
- research article
- Published by Springer Nature in Journal of Physiological Anthropology
- Vol. 39 (1) , 1-6
Abstract
Background: Recently, attempts have been made to use the pulse rate variability (PRV) as a surrogate for heart rate variability (HRV). PRV, however, may be caused by the fluctuations of left ventricular pre-ejection period and pulse transit time besides HRV. We examined whether PRV differs not only from HRV but also depending on the measurement site.Results: In five healthy subjects, pulse waves were measured simultaneously on both wrists and both forearms together with single-lead electrocardiogram (ECG) in the supine and sitting positions. Although average pulse interval showed no significant difference from average R-R interval in either positions, PRV showed greater power for the low-frequency (LF) and high-frequency (HF) components and lower LF/HF than HRV. The deviations of PRV from HRV in the supine and sitting positions were 13.2% and 7.9% for LF power, 24.5% and 18.3% for HF power, and − 15.0% and − 30.2% for LF/HF, respectively. While the average pulse interval showed 0.8% and 0.5% inter-site variations among the four sites in the supine and sitting positions, respectively, the inter-site variations in PRV were 4.0% and 3.6% for LF power, 3.8% and 4.7% for HF power, and 18.0% and 17.5% for LF/HF, respectively.Conclusions: These suggest that PRV shows not only systemic differences from HRV but also considerable inter-site variations.Keywords
This publication has 12 references indexed in Scilit:
- How accurate is pulse rate variability as an estimate of heart rate variability?International Journal of Cardiology, 2013
- Estimating heart rate using wrist-type Photoplethysmography and acceleration sensor while running2012
- Photoplethysmography pulse rate variability as a surrogate measurement of heart rate variability during non-stationary conditionsPhysiological Measurement, 2010
- The Acceleration Plethysmography System as a New Physiological Technology for Evaluating Autonomic ModulationsHealth Evaluation and Promotion, 2008
- Can Photoplethysmography Variability Serve as an Alternative Approach to Obtain Heart Rate Variability Information?Journal of Clinical Monitoring and Computing, 2007
- Combined photoplethysmographic monitoring of respiration rate and pulse: a comparison between different measurement sites in spontaneously breathing subjectsActa Anaesthesiologica Scandinavica, 2007
- Assessment of pulse rate variability by the method of pulse frequency demodulationBioMedical Engineering OnLine, 2005
- Pulse rate variability is not a surrogate for heart rate variability.1999
- Pulse rate variability is not a surrogate for heart rate variabilityClinical Science, 1999
- Assessment of frequency shifts in R-R interval variability and respiration with complex demodulationJournal of Applied Physiology, 1994