Real‐time control of hybrid active power filter using conservative power theory in industrial power system
Open Access
- 1 February 2017
- journal article
- research article
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 10 (2) , 196-207
Abstract
Industrial power system consists of several linear and non‐linear loads. The proliferation of non‐linear loads in power system causes the power system harmonics. Passive filters (PFs) are one of the ancient solutions to mitigate the harmonics. Some of the industrial power systems use PFs for harmonic compensation. Owing to dynamic load variation, the PFs are not the appropriate solution for harmonic compensation. To improve the system performance with existing PFs, this study presents the conservative power theory (CPT)‐based hybrid active power filter (HAPF) with Type‐II current controller for compensation of harmonics, reactive power and also the unbalance caused by different linear and non‐linear loads of an industrial power system. In this system, the CPT is used as a harmonic reference generator and Type‐II controller is designed for current control operation. The proposed HAPF overcomes the drawbacks of PFs and performs the compensation tasks effectively. The industrial power system with the proposed HAPF is modelled in MATLAB/Simulink environment and implemented in the real‐time (RT) using OPAL‐RT‐based RT simulator. The RT results are in compliance with IEEE 519‐2014 standard.Keywords
This publication has 20 references indexed in Scilit:
- Power System Harmonics and Passive Filter Designs2015
- Hybrid Active Filter With Variable Conductance for Harmonic Resonance Suppression in Industrial Power SystemsIEEE Transactions on Industrial Electronics, 2014
- A Combination of Shunt Hybrid Power Filter and Thyristor-Controlled Reactor for Power QualityIEEE Transactions on Industrial Electronics, 2013
- Analysis and design of different control strategies of hybrid active power filter based on the state modelIET Power Electronics, 2012
- Minimum inverter capacity design for LC-hybrid active power filters in three-phase four-wire distribution systemsIET Power Electronics, 2012
- Hysteresis current control of hybrid active power filtersIET Power Electronics, 2012
- Active Harmonic FiltersProceedings of the IEEE, 2005
- Passive Filters—Potentialities and LimitationsIEEE Transactions on Industry Applications, 2004
- A hybrid active filter for damping of harmonic resonance in industrial power systemsIEEE Transactions on Power Electronics, 2000