Lab on a chip for detecting Clara cell protein 16 (CC16) for potential screening of the workers exposed to respirable silica aerosol
- 20 September 2023
- journal article
- research article
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 27 (11) , 1-10
Abstract
Early detection of pulmonary responses to silica aerosol exposure, such as lung inflammation as well as early identification of silicosis initiation, is of great importance in disease prevention of workers. In this study, to early screen the health condition of the workers who are exposed to respirable silica dusts, an immunoassay lab on a chip (LOC) was designed, developed and fully characterized for analyzing Clara cell protein 16 (CC16) in serum which has been considered as one of the potential biomarkers of lung inflammation or lung damage due to the respirable silica dusts. Sandwich immunoassay of CC16 was performed on the LOC developed with a custom-designed portable analyzer using artificial serums spiked with CC16 protein first and then human serums obtained from the coal mine workers exposed to the respirable silica-containing dusts. The dynamic range of CC16 assay performed on the LOC was in a range of 0.625–20 ng/mL, and the achieved limit of detection (LOD) was around 0.35 ng/mL. The assay results of CC16 achieved from both the developed LOC and the conventional 96 well plate showed a reasonable corelation. The correlation between the conventional reader and the developed portable analyzer was found to be reasonable, resulting in R2 ~ 0.93. This study shows that the LOC developed for the early detection of CC16 can be potentially applied for the development of a field-deployable point-of-care testing (POCT) for the early monitoring of the field workers who are exposed to silica aerosol.Keywords
Funding Information
- CDC/NIOSH (75D3-0118-C-00391, 93908LQ, 75D3-0118-C-00391, 75D3-0118-C-00391, 93908LQ)
This publication has 29 references indexed in Scilit:
- A novel microfluidic microplate as the next generation assay platform for enzyme linked immunoassays (ELISA)Lab on a Chip, 2012
- Microfluidic designs and techniques using lab-on-a-chip devices for pathogen detection for point-of-care diagnosticsLab on a Chip, 2012
- Serum lactate dehydrogenase levels significantly correlate with radiological extent of disease and spirometric values in patients with silicosis due to denim sandblastingClinical Chemistry and Laboratory Medicine (CCLM), 2012
- Medical surveillance, exposure registries, and epidemiologic research for workers exposed to nanomaterialsToxicology, 2010
- Neopterin: Biomarker of cell-mediated immunity and potent usage as biomarker in silicosis and other occupational diseasesIndian Journal of Occupational and Environmental Medicine, 2008
- Methodological aspects on measurement of Clara cell protein in urine as a biomarker for airway toxicity, compared with serum levelsJournal of Applied Toxicology, 2006
- Mechanistically Identified Suitable Biomarkers of Exposure, Effect, and Susceptibility for Silicosis and Coal-Worker'S Pneumoconiosis: A Comprehensive ReviewJournal of Toxicology and Environmental Health, Part B, 2006
- Heme Oxygenase-1, a Potential Biomarker of Chronic Silicosis, Attenuates Silica-induced Lung InjuryAmerican Journal of Respiratory and Critical Care Medicine, 2006
- Cross sectional study on cytokine production (TNF-α, IL-8) in German coalminers with progressive massive fibrosis and in control miners using a rapid wholeblood assayBiomarkers, 2001
- Ex vivo cytokine release from whole blood: A routine method for health effect screeningExperimental and Toxicologic Pathology, 1996