Bon Ki Ku
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Bon Ki Ku has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Pramod Kulkarni
Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health
7 shared publications - Chen Wang
Health Effects Laboratory Division, National Institute for Occupational Safety and Health
3 shared publications - Kabir Rishi
Centers for Disease Control and Prevention (CDC), National Institute for Occupational Safety and Health (NIOSH), 1090 Tusculum Avenue, Cincinnati 45226, Ohio, United States
3 shared publications - Drew Thompson
Centers for Disease Control and Prevention (CDC), National Institute for Occupational Safety and Health (NIOSH), Division of Field Studies and Engineering (DFSE) , 1090 Tusculum Ave, Cincinnati, OH 45226
2 shared publications Gregory Deye
Centers for Disease Control and Prevention (CDC), National Institute for Occupational Safety and Health (NIOSH), Cincinnati, Ohio, USA
2 shared publicationsLeonid A. Turkevich
Division of Applied Research and Technology, Centers for Disease Control and Prevention (CDC), National Institute for Occupational Safety and Health (NIOSH)
2 shared publications
Latest Publications
- 17 December 2025
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Processes & Impacts
- Vol. 28 (1) , 84-97
Flow imaging microscopy-based method for rapid, high-throughput measurement of fiber count and length distributions in air
Discrepancies between Flow Imaging Microscopy (FIM) and Phase Contrast Microscopy (PCM) decrease as fiber counts increase, underscoring the value of FIM's high-throughput measurement capability.
- 17 December 2025
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Processes & Impacts
- Vol. 28 (1) , 84-97
Flow imaging microscopy-based method for rapid, high-throughput measurement of fiber count and length distributions in air
Discrepancies between Flow Imaging Microscopy (FIM) and Phase Contrast Microscopy (PCM) decrease as fiber counts increase, underscoring the value of FIM's high-throughput measurement capability.
- 23 August 2025
- Published by Oxford University Press (OUP) in Annals of Work Exposures and Health
- Vol. 70 (1)
Compatibility of engineered stone materials with tetrahydrofuran processing for crystalline silica analysis by XRD
This study investigated the compatibility of Tetrahydrofuran (THF) dissolution, following the procedures outlined in NIOSH Method 7500 and the similar OSHA ID-142 method, as a sample preparation technique for respirable crystalline silica (RCS) analysis in engineered stone materials compared to the muffle furnace (MF) ashing method. Our results revealed considerable variability in RCS content across different batches of engineered stone tested, underscoring the inherent material heterogeneity in engineered stone products. A statistically significant underestimation of RCS concentrations was observed when using THF dissolution for Stone A (polyester-based) samples collected on 47 mm polyvinyl chloride (PVC) filters, particularly at lower analyte loadings. In contrast, no statistically significant differences in RCS measurement were found between THF dissolution and MF ashing for the other 3 stone types, including one laboratory-synthetic material. The observed discrepancy in Stone A is likely attributed to the interaction of THF with its polyester resin binder, leading to swelling of the filter matrix and forming a non-volatile residue. This residue may physically entrap silica particles, hindering their complete recovery and subsequent quantification by X-ray diffraction (XRD). The suitability of THF processing as a sample preparation method is therefore highly dependent on the specific composition of the engineered stone. Based on these findings, MF ashing is recommended as the more reliable and universally applicable sample preparation method for engineered stone samples, especially those containing polyester resin binders. Caution should be exercised when considering THF dissolution for RCS analysis in engineered stones due to the potential for significant underestimation of actual RCS values, which could have implications for exposure assessments and regulatory compliance.
- 23 August 2025
- Published by Oxford University Press (OUP) in Annals of Work Exposures and Health
- Vol. 70 (1)
Compatibility of engineered stone materials with tetrahydrofuran processing for crystalline silica analysis by XRD
This study investigated the compatibility of Tetrahydrofuran (THF) dissolution, following the procedures outlined in NIOSH Method 7500 and the similar OSHA ID-142 method, as a sample preparation technique for respirable crystalline silica (RCS) analysis in engineered stone materials compared to the muffle furnace (MF) ashing method. Our results revealed considerable variability in RCS content across different batches of engineered stone tested, underscoring the inherent material heterogeneity in engineered stone products. A statistically significant underestimation of RCS concentrations was observed when using THF dissolution for Stone A (polyester-based) samples collected on 47 mm polyvinyl chloride (PVC) filters, particularly at lower analyte loadings. In contrast, no statistically significant differences in RCS measurement were found between THF dissolution and MF ashing for the other 3 stone types, including one laboratory-synthetic material. The observed discrepancy in Stone A is likely attributed to the interaction of THF with its polyester resin binder, leading to swelling of the filter matrix and forming a non-volatile residue. This residue may physically entrap silica particles, hindering their complete recovery and subsequent quantification by X-ray diffraction (XRD). The suitability of THF processing as a sample preparation method is therefore highly dependent on the specific composition of the engineered stone. Based on these findings, MF ashing is recommended as the more reliable and universally applicable sample preparation method for engineered stone samples, especially those containing polyester resin binders. Caution should be exercised when considering THF dissolution for RCS analysis in engineered stones due to the potential for significant underestimation of actual RCS values, which could have implications for exposure assessments and regulatory compliance.
- Open Access
- 10 December 2024
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 9 (51) , 50308-50317
Release of Crystalline Silica Nanoparticles during Engineered Stone Fabrication
Inhalation exposure to respirable crystalline silica (RCS) during the fabrication of engineered stone-based kitchen countertops has been on the rise in recent years and has become a significant occupational health problem in the United States and globally. Little is known about the presence of nanocrystalline silica (NCS), i.e., particles below 100 nm. We present a methodology to quantify the crystalline silica content in the sub-100 nm size fraction of the aerosol released during engineered stone fabrication using X-ray diffraction (XRD) and Fourier transform infrared (FTIR) spectroscopy. Aerosol was generated in a test chamber designed per EN 1093-3 and sampled using cascade impactors. XRD and FTIR analysis showed the presence of both α-quartz (15-60%) and cristobalite (10-50%) polymorphs in all size fractions. With increasing particle size, the cristobalite content increased. Seventy percent of the total aerosol mass in the sub-100 nm fraction was found to be crystalline silica, qualitatively confirmed by electron diffraction and electron energy loss spectroscopy. The presence of other minerals was detected in all size fractions; no polymeric resin binder was detected in the sub-100 nm fraction. Although the sub-100 nm fraction was about 1% of the aerosol mass, it accounted for 4-24% of the aerosol surface area based on the total lung deposition. If the surface area is a more relevant exposure metric, the assessment of the efficacy of current engineering control systems using mass as an exposure metric may not provide adequate protection.
- 10 December 2024
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 9 (51) , 50308-50317
Open AccessRelease of Crystalline Silica Nanoparticles during Engineered Stone Fabrication
Inhalation exposure to respirable crystalline silica (RCS) during the fabrication of engineered stone-based kitchen countertops has been on the rise in recent years and has become a significant occupational health problem in the United States and globally. Little is known about the presence of nanocrystalline silica (NCS), i.e., particles below 100 nm. We present a methodology to quantify the crystalline silica content in the sub-100 nm size fraction of the aerosol released during engineered stone fabrication using X-ray diffraction (XRD) and Fourier transform infrared (FTIR) spectroscopy. Aerosol was generated in a test chamber designed per EN 1093-3 and sampled using cascade impactors. XRD and FTIR analysis showed the presence of both α-quartz (15-60%) and cristobalite (10-50%) polymorphs in all size fractions. With increasing particle size, the cristobalite content increased. Seventy percent of the total aerosol mass in the sub-100 nm fraction was found to be crystalline silica, qualitatively confirmed by electron diffraction and electron energy loss spectroscopy. The presence of other minerals was detected in all size fractions; no polymeric resin binder was detected in the sub-100 nm fraction. Although the sub-100 nm fraction was about 1% of the aerosol mass, it accounted for 4-24% of the aerosol surface area based on the total lung deposition. If the surface area is a more relevant exposure metric, the assessment of the efficacy of current engineering control systems using mass as an exposure metric may not provide adequate protection.
- 20 September 2023
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 27 (11) , 1-10
Lab on a chip for detecting Clara cell protein 16 (CC16) for potential screening of the workers exposed to respirable silica aerosol
Early detection of pulmonary responses to silica aerosol exposure, such as lung inflammation as well as early identification of silicosis initiation, is of great importance in disease prevention of workers. In this study, to early screen the health condition of the workers who are exposed to respirable silica dusts, an immunoassay lab on a chip (LOC) was designed, developed and fully characterized for analyzing Clara cell protein 16 (CC16) in serum which has been considered as one of the potential biomarkers of lung inflammation or lung damage due to the respirable silica dusts. Sandwich immunoassay of CC16 was performed on the LOC developed with a custom-designed portable analyzer using artificial serums spiked with CC16 protein first and then human serums obtained from the coal mine workers exposed to the respirable silica-containing dusts. The dynamic range of CC16 assay performed on the LOC was in a range of 0.625–20 ng/mL, and the achieved limit of detection (LOD) was around 0.35 ng/mL. The assay results of CC16 achieved from both the developed LOC and the conventional 96 well plate showed a reasonable corelation. The correlation between the conventional reader and the developed portable analyzer was found to be reasonable, resulting in R2 ~ 0.93. This study shows that the LOC developed for the early detection of CC16 can be potentially applied for the development of a field-deployable point-of-care testing (POCT) for the early monitoring of the field workers who are exposed to silica aerosol.
- 20 September 2023
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 27 (11) , 1-10
Lab on a chip for detecting Clara cell protein 16 (CC16) for potential screening of the workers exposed to respirable silica aerosol
Early detection of pulmonary responses to silica aerosol exposure, such as lung inflammation as well as early identification of silicosis initiation, is of great importance in disease prevention of workers. In this study, to early screen the health condition of the workers who are exposed to respirable silica dusts, an immunoassay lab on a chip (LOC) was designed, developed and fully characterized for analyzing Clara cell protein 16 (CC16) in serum which has been considered as one of the potential biomarkers of lung inflammation or lung damage due to the respirable silica dusts. Sandwich immunoassay of CC16 was performed on the LOC developed with a custom-designed portable analyzer using artificial serums spiked with CC16 protein first and then human serums obtained from the coal mine workers exposed to the respirable silica-containing dusts. The dynamic range of CC16 assay performed on the LOC was in a range of 0.625–20 ng/mL, and the achieved limit of detection (LOD) was around 0.35 ng/mL. The assay results of CC16 achieved from both the developed LOC and the conventional 96 well plate showed a reasonable corelation. The correlation between the conventional reader and the developed portable analyzer was found to be reasonable, resulting in R2 ~ 0.93. This study shows that the LOC developed for the early detection of CC16 can be potentially applied for the development of a field-deployable point-of-care testing (POCT) for the early monitoring of the field workers who are exposed to silica aerosol.
- 26 August 2019
- Published by Taylor & Francis in Aerosol Science and Technology
- Vol. 53 (10) , 1217-1227
Collection efficiency of airborne fibers on nylon mesh screens with different pore sizes and configurations
Aerodynamic behavior of airborne fibers including high-aspect ratio particles plays an important role in aerosol filtration and lung deposition. Fiber length is considered to be an important parameter in causing toxicological responses of elongate mineral particles, including asbestos, as well as one of the factors affecting lung deposition. In order to estimate the toxicity of fibers as a function of fiber length, it is required to separate fibers by length and understand mechanisms related to fiber separation for use in toxicology studies. In this study, we used nylon mesh screens with different pore sizes as a separation method to remove long fibers and measured screen collection efficiency of glass fibers (a surrogate for asbestos) as a function of aerodynamic diameter with the aim to prepare toxicology samples free of long fibers and/or harvest long fibers from the screen. Two screen configurations ([i] without a laminar flow entrance length, and [ii] with the entrance length) were tested to investigate the effect of screen pore size (10, 20, and 60 µm) and screen configuration on collection efficiency of fibers. Screen collection efficiency (η) was obtained based on measurements of downstream concentrations of a test chamber either without or with a screen. The results showed that screen collection efficiency increases as screen pore size decreases from 60 to 10 µm for both cases with and without entrance lengths. For the screen configuration without entrance length, higher collection efficiency was obtained than the case with entrance length probably due to increased impaction caused by the close proximity of inlet to screen. In addition, the difference between the collection efficiencies for the different configurations was small in the aerodynamic size range below 3 µm while it increased in the size range from 3 to about 7 µm, indicating that as large aerodynamic diameter is associated with longer fibers, some differential selection of fibers is possible. Modified model collection efficiency for 10 and 20 µm screens based on the interception predicts well the measured data for the case with entrance length, indicating that the fiber deposition on these screens occurs dominantly through the interception mechanism in the micrometer size range under a given flow condition.
- 26 August 2019
- Published by Taylor & Francis in Aerosol Science and Technology
- Vol. 53 (10) , 1217-1227
Collection efficiency of airborne fibers on nylon mesh screens with different pore sizes and configurations
Aerodynamic behavior of airborne fibers including high-aspect ratio particles plays an important role in aerosol filtration and lung deposition. Fiber length is considered to be an important parameter in causing toxicological responses of elongate mineral particles, including asbestos, as well as one of the factors affecting lung deposition. In order to estimate the toxicity of fibers as a function of fiber length, it is required to separate fibers by length and understand mechanisms related to fiber separation for use in toxicology studies. In this study, we used nylon mesh screens with different pore sizes as a separation method to remove long fibers and measured screen collection efficiency of glass fibers (a surrogate for asbestos) as a function of aerodynamic diameter with the aim to prepare toxicology samples free of long fibers and/or harvest long fibers from the screen. Two screen configurations ([i] without a laminar flow entrance length, and [ii] with the entrance length) were tested to investigate the effect of screen pore size (10, 20, and 60 µm) and screen configuration on collection efficiency of fibers. Screen collection efficiency (η) was obtained based on measurements of downstream concentrations of a test chamber either without or with a screen. The results showed that screen collection efficiency increases as screen pore size decreases from 60 to 10 µm for both cases with and without entrance lengths. For the screen configuration without entrance length, higher collection efficiency was obtained than the case with entrance length probably due to increased impaction caused by the close proximity of inlet to screen. In addition, the difference between the collection efficiencies for the different configurations was small in the aerodynamic size range below 3 µm while it increased in the size range from 3 to about 7 µm, indicating that as large aerodynamic diameter is associated with longer fibers, some differential selection of fibers is possible. Modified model collection efficiency for 10 and 20 µm screens based on the interception predicts well the measured data for the case with entrance length, indicating that the fiber deposition on these screens occurs dominantly through the interception mechanism in the micrometer size range under a given flow condition.
- 1 January 2019
- Published by Elsevier in Journal of Aerosol Science
- Vol. 127, 38-48
Aerosolization and characterization of carbon nanotube and nanofiber materials: Relationship between aerosol properties and bulk density
- 1 January 2019
- Published by Elsevier in Journal of Aerosol Science
- Vol. 127, 38-48
Aerosolization and characterization of carbon nanotube and nanofiber materials: Relationship between aerosol properties and bulk density
- Open Access
- 7 March 2018
- Published by Taylor & Francis in Aerosol Science and Technology
- Vol. 52 (5) , 597-608
Application of fractal theory to estimation of equivalent diameters of airborne carbon nanotube and nanofiber agglomerates
Understanding transport characteristics of airborne nanotubes and nanofibers is important for assessing their fate in the respiratory system. Typically, diffusion and aerodynamic diameters capture key deposition mechanisms of near-spherical particles such as diffusion and impaction in the submicrometer size range. For nonspherical particles with high aspect ratios, such as aerosolized carbon nanotubes, these diameters can vary widely, requiring their independent measurement. The objective of this study was to develop an approach to provide approximate estimates of aerodynamic- and diffusion-equivalent diameters of airborne carbon nanotubes (CNTs) and carbon nanofibers (CNFs) using their morphological characteristics obtained from electron micrographs. The as-received CNT and CNF materials were aerosolized using different techniques such as dry dispersion and nebulization. Mobility and aerodynamic diameters of test aerosol were directly deduced from tandem measurement of particle mobility and mass. The same test aerosol was mobility-classified and subsequently collected on a microscopy grid for transmission electron microscopy (TEM) analysis. TEM micrographs were used to obtain projected area, maximum projected length, and two-dimensional (2-D) radius of gyration of test particles. Estimates of the aerodynamic diameter and the diffusion diameter were obtained by applying the fractal theory developed for aerosol agglomerates of primary spherical particles. After accounting for the particle dynamic shape factor, estimated aerodynamic diameters agreed with those from the direct measurements (using tandem mobility-mass technique) within 30–40% for the agglomerates with relatively open structures while the diffusion diameters agreed within 40–50%. The uncertainty of these estimates mainly depends on degree of overlapping structures in the microscopy image and nonuniformity in tube diameter. The approach could be useful in calculating approximate airborne properties from microscopy images of CNT and CNF agglomerates with relatively open structures. This article not subject to US copyright law
- 7 March 2018
- Published by Taylor & Francis in Aerosol Science and Technology
- Vol. 52 (5) , 597-608
Open AccessApplication of fractal theory to estimation of equivalent diameters of airborne carbon nanotube and nanofiber agglomerates
Understanding transport characteristics of airborne nanotubes and nanofibers is important for assessing their fate in the respiratory system. Typically, diffusion and aerodynamic diameters capture key deposition mechanisms of near-spherical particles such as diffusion and impaction in the submicrometer size range. For nonspherical particles with high aspect ratios, such as aerosolized carbon nanotubes, these diameters can vary widely, requiring their independent measurement. The objective of this study was to develop an approach to provide approximate estimates of aerodynamic- and diffusion-equivalent diameters of airborne carbon nanotubes (CNTs) and carbon nanofibers (CNFs) using their morphological characteristics obtained from electron micrographs. The as-received CNT and CNF materials were aerosolized using different techniques such as dry dispersion and nebulization. Mobility and aerodynamic diameters of test aerosol were directly deduced from tandem measurement of particle mobility and mass. The same test aerosol was mobility-classified and subsequently collected on a microscopy grid for transmission electron microscopy (TEM) analysis. TEM micrographs were used to obtain projected area, maximum projected length, and two-dimensional (2-D) radius of gyration of test particles. Estimates of the aerodynamic diameter and the diffusion diameter were obtained by applying the fractal theory developed for aerosol agglomerates of primary spherical particles. After accounting for the particle dynamic shape factor, estimated aerodynamic diameters agreed with those from the direct measurements (using tandem mobility-mass technique) within 30–40% for the agglomerates with relatively open structures while the diffusion diameters agreed within 40–50%. The uncertainty of these estimates mainly depends on degree of overlapping structures in the microscopy image and nonuniformity in tube diameter. The approach could be useful in calculating approximate airborne properties from microscopy images of CNT and CNF agglomerates with relatively open structures. This article not subject to US copyright law
- 1 December 2015
- Published by Elsevier in Journal of Aerosol Science
- Vol. 90, 169-181
Measurement of transport properties of aerosolized nanomaterials
- 1 December 2015
- Published by Elsevier in Journal of Aerosol Science
- Vol. 90, 169-181
Measurement of transport properties of aerosolized nanomaterials
- 14 January 2014
- Published by Taylor & Francis in Inhalation Toxicology
- Vol. 26 (2) , 70-83
Efficacy of screens in removing long fibers from an aerosol stream – sample preparation technique for toxicology studies
Fiber dimension (especially length) and biopersistence are thought to be important variables in determining the pathogenicity of asbestos and other elongate mineral particles. In order to prepare samples of fibers for toxicology studies, it is necessary to develop and evaluate methods for separating fibers by length in the micrometer size range. In this study, we have filtered an aerosol of fibers through nylon screens to investigate whether such screens can efficiently remove the long fibers (L >20 µm, a typical macrophage size) from the aerosol stream. Such a sample, deficient in long fibers, could then be used as the control in a toxicology study to investigate the role of length. A well-dispersed aerosol of glass fibers (a surrogate for asbestos) was generated by vortex shaking a Japan Fibrous Material Research Association (JFMRA) glass fiber powder. Fibers were collected on a mixed cellulose ester (MCE) filter, imaged with phase contrast microscopy (PCM) and lengths were measured. Length distributions of the fibers that penetrated through various screens (10, 20 and 60 µm mesh sizes) were analyzed; additional study was made of fibers that penetrated through double screen and centrally blocked screen configurations. Single screens were not particularly efficient in removing the long fibers; however, the alternative configurations, especially the centrally blocked screen configuration, yielded samples substantially free of the long fibers.
- 14 January 2014
- Published by Taylor & Francis in Inhalation Toxicology
- Vol. 26 (2) , 70-83
Efficacy of screens in removing long fibers from an aerosol stream – sample preparation technique for toxicology studies
Fiber dimension (especially length) and biopersistence are thought to be important variables in determining the pathogenicity of asbestos and other elongate mineral particles. In order to prepare samples of fibers for toxicology studies, it is necessary to develop and evaluate methods for separating fibers by length in the micrometer size range. In this study, we have filtered an aerosol of fibers through nylon screens to investigate whether such screens can efficiently remove the long fibers (L >20 µm, a typical macrophage size) from the aerosol stream. Such a sample, deficient in long fibers, could then be used as the control in a toxicology study to investigate the role of length. A well-dispersed aerosol of glass fibers (a surrogate for asbestos) was generated by vortex shaking a Japan Fibrous Material Research Association (JFMRA) glass fiber powder. Fibers were collected on a mixed cellulose ester (MCE) filter, imaged with phase contrast microscopy (PCM) and lengths were measured. Length distributions of the fibers that penetrated through various screens (10, 20 and 60 µm mesh sizes) were analyzed; additional study was made of fibers that penetrated through double screen and centrally blocked screen configurations. Single screens were not particularly efficient in removing the long fibers; however, the alternative configurations, especially the centrally blocked screen configuration, yielded samples substantially free of the long fibers.