Evaluation of Whole Brain Intravoxel Incoherent Motion (IVIM) Imaging
Open Access
- 20 March 2024
- journal article
- research article
- Published by MDPI AG in Diagnostics
- Vol. 14 (6) , 653
Abstract
Intravoxel Incoherent Motion (IVIM) imaging provides non-invasive perfusion measurements, eliminating the need for contrast agents. This work explores the feasibility of IVIM imaging in whole brain perfusion studies, where an isotropic 1 mm voxel is widely accepted as a standard. This study follows the validity of a time-limited, precise, segmentation-ready whole-brain IVIM protocol suitable for clinical reality. To assess the influence of SNR on the estimation of S0, f, D*, and D IVIM parameters, a series of measurements and simulations were performed in MATLAB for the following three estimation techniques: segmented grid search, segmented curve fitting, and one-step curve fitting, utilizing known “ground truth” and noised data. Scanner-specific SNR was estimated based on a healthy subject IVIM MRI study in a 3T scanner. Measurements were conducted for 25.6 × 25.6 × 14.4 cm FOV with a 256 × 256 in-plane resolution and 72 slices, resulting in 1 × 1 × 2 mm voxel size. Simulations were performed for 36 SNR levels around the measured SNR value. For a single voxel grid, the search algorithm mean relative error Ŝ0, , , and of at the expected SNR level were 5.00%, 81.91%, 76.31%, and 18.34%, respectively. Analysis has shown that high-resolution IVIM imaging is possible, although there is significant variation in both accuracy and precision, depending on SNR and the chosen estimation method.
Keywords
All Related Versions
Funding Information
- Polish National Science Centre (UMO-2018/31/B/ST7/01888)
This publication has 31 references indexed in Scilit:
- Optimizing b‐values schemes for diffusion MRI of the brain with segmented Intravoxel Incoherent Motion (IVIM) modelJournal of Applied Clinical Medical Physics, 2023
- MRI: Evaluating the Application of FOCUS‐MUSE Diffusion‐Weighted Imaging in the Pancreas in Comparison With FOCUS, MUSE, and Single‐Shot DWIsJournal of Magnetic Resonance Imaging, 2022
- Evaluation of intravoxel incoherent motion fitting methods in low‐perfused tissueJournal of Magnetic Resonance Imaging, 2016
- Gibbs‐ringing artifact removal based on local subvoxel‐shiftsMagnetic Resonance in Medicine, 2015
- Diffusion MRI noise mapping using random matrix theoryMagnetic Resonance in Medicine, 2015
- IVIM analysis of brain tumors: an investigation of the relaxation effects of CSF, blood, and tumor tissue on the estimated perfusion fractionMagnetic Resonance Materials in Physics, Biology and Medicine, 2014
- Intravoxel incoherent motion (IVIM) imaging at different magnetic field strengths: What is feasible?Magnetic Resonance Imaging, 2014
- Measuring brain perfusion with intravoxel incoherent motion (IVIM): Initial clinical experienceJournal of Magnetic Resonance Imaging, 2013
- Statistical parametric mapping2007
- Über die von der molekularkinetischen Theorie der Wärme geforderte Bewegung von in ruhenden Flüssigkeiten suspendierten TeilchenAnnalen der Physik, 1905