Piotr Bogorodzki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Piotr Bogorodzki has a total of 176 co-authors. Here are the top co-authors by number of shared publications:
- Ewa Piątkowska-Janko
Nalecz Institute of Biocybernetics and Biomedical Engineering PAS
14 shared publications - Tomasz Wolak
Bioimaging Research Center, Institute of Physiology and Pathology of Hearing, Warsaw, Poland
7 shared publications - Kamil Lipiński
Institute of Radioelectronics and Multimedia Technology, The Faculty of Electronics and Information Technology, Warsaw University of Technology, Nowowiejska 15/19, 00-655 Warsaw, Poland
5 shared publications - Paweł Grieb
Department of Experimental Pharmacology, Mossakowski Medical Research Centre, Polish Academy of Sciences, A. Pawińskiego 5, 02-106 Warsaw, Poland
5 shared publications Jadwiga Rogowska
E Institute of Radioelectronics, Warsaw Technical University, Poland
4 shared publications- Konrad Werys
Oxford Centre for Clinical Magnetic Resonance Research, John Radcliffe Hospital, Headington, Oxford, UK
4 shared publications
Latest Publications
- Open Access
- 11 June 2026
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 139 (22)
Ferromagnetic resonances in thin films—Electrodynamic analysis and experiments employing multimode rectangular cavity and broadband coplanar waveguide techniques
Rigorous electrodynamic analysis of resonances in rectangular TMn,m,0z mode resonators containing a thin in-plane magnetized ferromagnetic film is presented. Apart from the resonance frequencies and Q-factors, the electromagnetic field distribution is analyzed showing the appearance of a giant microwave magnetic field component perpendicular to the sample at the resonance frequencies of both the dominant and higher order modes. This confirms the plasmonic-like behavior of resonances in thin ferromagnetic films, where the term is used in the electrodynamic sense of subwavelength resonances. The conductivity of metallic ferromagnetic films is accounted for in computations. Resonance curve broadening due to conductivity is predicted for larger conductivities and/or for thicker samples. Results of rigorous computations are compared with the perturbation theory. A rectangular TMn,m,0z mode cavity is used for measurements of the saturation magnetization and Gilbert damping factor of thin CoFeB films at several frequencies in the range 4–12 GHz showing agreement with the broadband coplanar waveguide technique. The Gilbert damping factor of a single-crystal yttrium iron garnet film grown on a GGG substrate and an amorphous CoFeB thin film were determined from measurements of their Q-factors, employing a vector network analyzer, and considering the sample as a magnetic plasmon-like resonator coupled to the coplanar line.
- 11 June 2026
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 139 (22)
Open AccessFerromagnetic resonances in thin films—Electrodynamic analysis and experiments employing multimode rectangular cavity and broadband coplanar waveguide techniques
Rigorous electrodynamic analysis of resonances in rectangular TMn,m,0z mode resonators containing a thin in-plane magnetized ferromagnetic film is presented. Apart from the resonance frequencies and Q-factors, the electromagnetic field distribution is analyzed showing the appearance of a giant microwave magnetic field component perpendicular to the sample at the resonance frequencies of both the dominant and higher order modes. This confirms the plasmonic-like behavior of resonances in thin ferromagnetic films, where the term is used in the electrodynamic sense of subwavelength resonances. The conductivity of metallic ferromagnetic films is accounted for in computations. Resonance curve broadening due to conductivity is predicted for larger conductivities and/or for thicker samples. Results of rigorous computations are compared with the perturbation theory. A rectangular TMn,m,0z mode cavity is used for measurements of the saturation magnetization and Gilbert damping factor of thin CoFeB films at several frequencies in the range 4–12 GHz showing agreement with the broadband coplanar waveguide technique. The Gilbert damping factor of a single-crystal yttrium iron garnet film grown on a GGG substrate and an amorphous CoFeB thin film were determined from measurements of their Q-factors, employing a vector network analyzer, and considering the sample as a magnetic plasmon-like resonator coupled to the coplanar line.
- Open Access
- 21 January 2026
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 17 (1) , 54
Analysis of the Feasibility of Concurrent Application of Magnetic Nanoparticles as MRI Contrast Agents and for Magnetic Hyperthermia
The aim of the article was to analyze the potential simultaneous use of magnetic nanoparticles as contrast agents in MRI imaging and for magnetic hyperthermia. The study proposed characterizing the nanoparticles using various measurement methods in order to investigate the relationships between different properties. The first stage involved measuring images of nanoparticle samples using scanning transmission electron microscopy (TEM) and dynamic light scattering (DLS). The diameter distribution of nanoparticles was determined based on image segmentation. The next step involved measuring relaxation properties of nanoparticles in low and high magnetic fields. The research was carried out for nanoparticle solutions of various concentrations and properties. The last step was measuring calorimetric properties of nanoparticles as a thermal source under alternating magnetic field excitation conditions. The range of nanoparticle diameters (20–25 nm) for which maximum losses occur in an alternating magnetic field corresponds to the diameter range in which the maximum r2 relaxivity is observed.
- 21 January 2026
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 17 (1) , 54
Open AccessAnalysis of the Feasibility of Concurrent Application of Magnetic Nanoparticles as MRI Contrast Agents and for Magnetic Hyperthermia
The aim of the article was to analyze the potential simultaneous use of magnetic nanoparticles as contrast agents in MRI imaging and for magnetic hyperthermia. The study proposed characterizing the nanoparticles using various measurement methods in order to investigate the relationships between different properties. The first stage involved measuring images of nanoparticle samples using scanning transmission electron microscopy (TEM) and dynamic light scattering (DLS). The diameter distribution of nanoparticles was determined based on image segmentation. The next step involved measuring relaxation properties of nanoparticles in low and high magnetic fields. The research was carried out for nanoparticle solutions of various concentrations and properties. The last step was measuring calorimetric properties of nanoparticles as a thermal source under alternating magnetic field excitation conditions. The range of nanoparticle diameters (20–25 nm) for which maximum losses occur in an alternating magnetic field corresponds to the diameter range in which the maximum r2 relaxivity is observed.
- Open Access
Impedance Analysis of a Two-Layer Air-Core Coil for AC Magnetometry Applications
The aim of the study was to analyze the impedance characteristics of the transmitting coil used in a system for AC magnetometry and the measurement of the Specific Absorption Rate (SAR) of magnetic nanoparticles. A theoretical relationship for the current distribution in a multilayer air-core coil was derived. The formulas for the coil’s stray capacitance were modified to account for additional spacing between layers, introduced to reduce the interlayer capacitance. The developed theory was applied to a two-layer air-core coil with an additional gap between the layers. The frequency dependence of the coil impedance was measured. The measurements confirmed an extension of the useful operating frequency range of the constructed coil.
Open AccessImpedance Analysis of a Two-Layer Air-Core Coil for AC Magnetometry Applications
The aim of the study was to analyze the impedance characteristics of the transmitting coil used in a system for AC magnetometry and the measurement of the Specific Absorption Rate (SAR) of magnetic nanoparticles. A theoretical relationship for the current distribution in a multilayer air-core coil was derived. The formulas for the coil’s stray capacitance were modified to account for additional spacing between layers, introduced to reduce the interlayer capacitance. The developed theory was applied to a two-layer air-core coil with an additional gap between the layers. The frequency dependence of the coil impedance was measured. The measurements confirmed an extension of the useful operating frequency range of the constructed coil.
- Open Access
- 20 March 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (6) , 653
Evaluation of Whole Brain Intravoxel Incoherent Motion (IVIM) Imaging
Intravoxel Incoherent Motion (IVIM) imaging provides non-invasive perfusion measurements, eliminating the need for contrast agents. This work explores the feasibility of IVIM imaging in whole brain perfusion studies, where an isotropic 1 mm voxel is widely accepted as a standard. This study follows the validity of a time-limited, precise, segmentation-ready whole-brain IVIM protocol suitable for clinical reality. To assess the influence of SNR on the estimation of S0, f, D*, and D IVIM parameters, a series of measurements and simulations were performed in MATLAB for the following three estimation techniques: segmented grid search, segmented curve fitting, and one-step curve fitting, utilizing known “ground truth” and noised data. Scanner-specific SNR was estimated based on a healthy subject IVIM MRI study in a 3T scanner. Measurements were conducted for 25.6 × 25.6 × 14.4 cm FOV with a 256 × 256 in-plane resolution and 72 slices, resulting in 1 × 1 × 2 mm voxel size. Simulations were performed for 36 SNR levels around the measured SNR value. For a single voxel grid, the search algorithm mean relative error Ŝ0, , , and of at the expected SNR level were 5.00%, 81.91%, 76.31%, and 18.34%, respectively. Analysis has shown that high-resolution IVIM imaging is possible, although there is significant variation in both accuracy and precision, depending on SNR and the chosen estimation method.- 20 March 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (6) , 653
Open AccessEvaluation of Whole Brain Intravoxel Incoherent Motion (IVIM) Imaging
Intravoxel Incoherent Motion (IVIM) imaging provides non-invasive perfusion measurements, eliminating the need for contrast agents. This work explores the feasibility of IVIM imaging in whole brain perfusion studies, where an isotropic 1 mm voxel is widely accepted as a standard. This study follows the validity of a time-limited, precise, segmentation-ready whole-brain IVIM protocol suitable for clinical reality. To assess the influence of SNR on the estimation of S0, f, D*, and D IVIM parameters, a series of measurements and simulations were performed in MATLAB for the following three estimation techniques: segmented grid search, segmented curve fitting, and one-step curve fitting, utilizing known “ground truth” and noised data. Scanner-specific SNR was estimated based on a healthy subject IVIM MRI study in a 3T scanner. Measurements were conducted for 25.6 × 25.6 × 14.4 cm FOV with a 256 × 256 in-plane resolution and 72 slices, resulting in 1 × 1 × 2 mm voxel size. Simulations were performed for 36 SNR levels around the measured SNR value. For a single voxel grid, the search algorithm mean relative error Ŝ0, , , and of at the expected SNR level were 5.00%, 81.91%, 76.31%, and 18.34%, respectively. Analysis has shown that high-resolution IVIM imaging is possible, although there is significant variation in both accuracy and precision, depending on SNR and the chosen estimation method. - Open Access
- 19 February 2024
- Published by MDPI AG in Preprints.org
Evaluation of Whole Brain Intra Voxel Incoherent Motion (IVIM) Imaging
Intra Voxel Incoherent Motion (IVIM) imaging provides non-invasive perfusion measurements, eliminating the need for contrast agents. The aim of this work was to explore the feasibility of IVIM in whole brain perfusion studies, where isotropic 1mm voxel is widely accepted as a standard. This study treats on validity of time limited, precise, segmentation ready Whole Brain IVIM imaging protocol suitable for clinical reality. To assess the influence of SNR on the estimation of S0, f, D* and D IVIM parameters a series of measurements and simulations under MATLAB environment were performed for three estimation techniques, utilizing known “ground truth” and noised data. Scanner specific SNR was estimated based on healthy subject IVIM MRI study in 3T scanner. Measurements were conducted for 25,6x25,6x14,4 cm FOV with 256x256 in plane resolution and 72 slices resulting in 1x1x2 mm voxel size. Simulations were performed for 36 SNR levels around measured SNR value. Single voxel grid search estimation method mean relative error for S0 f D* D estimates at measured SNR level were: 5.00%,81.91%, 76.31%, 18.34% respectively. Analysis has shown that high resolution IVIM is possible, although there is significant variation in estimation accuracy and precision depending on SNR level and chosen estimation method.
- 19 February 2024
- Published by MDPI AG in Preprints.org
Open AccessEvaluation of Whole Brain Intra Voxel Incoherent Motion (IVIM) Imaging
Intra Voxel Incoherent Motion (IVIM) imaging provides non-invasive perfusion measurements, eliminating the need for contrast agents. The aim of this work was to explore the feasibility of IVIM in whole brain perfusion studies, where isotropic 1mm voxel is widely accepted as a standard. This study treats on validity of time limited, precise, segmentation ready Whole Brain IVIM imaging protocol suitable for clinical reality. To assess the influence of SNR on the estimation of S0, f, D* and D IVIM parameters a series of measurements and simulations under MATLAB environment were performed for three estimation techniques, utilizing known “ground truth” and noised data. Scanner specific SNR was estimated based on healthy subject IVIM MRI study in 3T scanner. Measurements were conducted for 25,6x25,6x14,4 cm FOV with 256x256 in plane resolution and 72 slices resulting in 1x1x2 mm voxel size. Simulations were performed for 36 SNR levels around measured SNR value. Single voxel grid search estimation method mean relative error for S0 f D* D estimates at measured SNR level were: 5.00%,81.91%, 76.31%, 18.34% respectively. Analysis has shown that high resolution IVIM is possible, although there is significant variation in estimation accuracy and precision depending on SNR level and chosen estimation method.
- Open Access
- 5 November 2023
- Published by Elsevier in IBRO Neuroscience Reports
- Vol. 15, S853
EMPATHIZING WITH PAIN OF OTHERS – THE EFFECT OF SENSORY PROCESSING SENSITIVITY
- 5 November 2023
- Published by Elsevier in IBRO Neuroscience Reports
- Vol. 15, S853
Open AccessEMPATHIZING WITH PAIN OF OTHERS – THE EFFECT OF SENSORY PROCESSING SENSITIVITY
- 11 September 2023
- Published by Springer Nature
- p. 407-420
Application of Unsuppressed Water Peaks for MRS Thermometry
- 11 September 2023
- Published by Springer Nature
- p. 407-420
Application of Unsuppressed Water Peaks for MRS Thermometry
- 11 September 2023
- Published by Springer Nature
- p. 131-146
Optimization of the BOLD Hemodynamic Response Function for EEG-FMRI Studies in Epilepsy
- 11 September 2023
- Published by Springer Nature
- p. 131-146
Optimization of the BOLD Hemodynamic Response Function for EEG-FMRI Studies in Epilepsy
- Open Access
The Hybrid System for the Magnetic Characterization of Superparamagnetic Nanoparticles
The characterization of nanoparticles is crucial in several medical applications, such as hyperthermic therapy, which heats superparamagnetic nanoparticles with an external electromagnetic field. The knowledge of heating ability (magnetic losses) in AC magnetic field frequency function allows for selecting the optimal excitation. A hybrid system for the characterization of superparamagnetic nanoparticles was designed and tested. The proposed setup consists of an excitation coil and two sensing probes: calorimetric and magnetic. The measurements of the imaginary part of the complex magnetic susceptibility of superparamagnetic nanoparticles are possible in the kilohertz range. The system was verified using a set of nanoparticles with different diameters. The measurement procedure was described and verified. The results confirmed that an elaborated sensor system and measuring procedures could properly characterize the magnetic characteristics of nanoparticles. The main advantage of this system is the ability to compare both characteristics and confirm the selection of optimal excitation parameters.
Open AccessThe Hybrid System for the Magnetic Characterization of Superparamagnetic Nanoparticles
The characterization of nanoparticles is crucial in several medical applications, such as hyperthermic therapy, which heats superparamagnetic nanoparticles with an external electromagnetic field. The knowledge of heating ability (magnetic losses) in AC magnetic field frequency function allows for selecting the optimal excitation. A hybrid system for the characterization of superparamagnetic nanoparticles was designed and tested. The proposed setup consists of an excitation coil and two sensing probes: calorimetric and magnetic. The measurements of the imaginary part of the complex magnetic susceptibility of superparamagnetic nanoparticles are possible in the kilohertz range. The system was verified using a set of nanoparticles with different diameters. The measurement procedure was described and verified. The results confirmed that an elaborated sensor system and measuring procedures could properly characterize the magnetic characteristics of nanoparticles. The main advantage of this system is the ability to compare both characteristics and confirm the selection of optimal excitation parameters.
- 1 September 2022
- Published by Taylor & Francis
- p. 129-139
Gabor-Filter-based Longitudinal Strain Estimation from Tagged MRI
Local contractility evaluation is a promising area of cardiovascular research. We propose and validate strain calculation method based on Gabor filters used on tagged magnetic resonance images. We focus on longitudinal strain calculated from images of the heart in its long axis. We validate the results on studies of both a healthy volunteer and two cardiomiopathy patients.
- 1 September 2022
- Published by Taylor & Francis
- p. 129-139
Gabor-Filter-based Longitudinal Strain Estimation from Tagged MRI
Local contractility evaluation is a promising area of cardiovascular research. We propose and validate strain calculation method based on Gabor filters used on tagged magnetic resonance images. We focus on longitudinal strain calculated from images of the heart in its long axis. We validate the results on studies of both a healthy volunteer and two cardiomiopathy patients.