Imaging near titanium total hip arthroplasty at 0. 55 T compared with 3 T
Open Access
- 28 March 2025
- journal article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (1) , 242-250
Abstract
Purpose: To compare 0.55 T and 3 T MRI for imaging patients with titanium total hip arthroplasty (THA). Patients with orthopedic metallic implants often require diagnostic imaging to evaluate adjacent tissues. MRI performance measures, including artifact levels and SNR, vary with field strength. Methods: Six patients with titanium THA were scanned with similar protocols at 0.55 T and 3 T, including proton density (PD) weighted turbo spin echo (TSE), PD TSE with view‐angle tilting (TSE + VAT), PD slice encoding for metal artifact correction (SEMAC), and short tau inversion recovery with SEMAC (STIR‐SEMAC). Images from both field strengths were scored by two readers and qualitatively and quantitatively compared. Results: Diagnostic confidence was significantly higher at 0.55 T compared to 3 T. Perceived metal artifact was substantially reduced at 0.55 T compared to 3 T. At 0.55 T, diagnostic imaging was achieved both without and with multi spectral imaging (MSI) for PD weighted images. Conclusion: Compared to 3 T, 0.55 T MRI offers substantially reduced metal artifacts and higher diagnostic confidence when imaging titanium THA. Advanced multi‐spectral techniques may not be required when the metallic components are entirely titanium.Keywords
Funding Information
- National Science Foundation of Sri Lanka (1828736)
- National Institutes of Health (R01‐AR078912)
This publication has 17 references indexed in Scilit:
- Diagnosing periprosthetic hip joint infection with new-generation 0.55 T MRIEuropean Journal of Radiology, 2024
- Advanced deep learning-based image reconstruction in lumbar spine MRI at 0.55 T – Effects on image quality and acquisition time in comparison to conventional deep learning-based reconstructionEuropean Journal of Radiology Open, 2024
- Comparing Metal Artifact Severity and Ability to Assess Near-Metal Anatomy Between 0.55 T and 1.5 T MRI in Patients with Metallic Spinal Implants—A Scanner Comparison StudyAcademic Radiology, 2024
- Highlights of the 2022 American Joint Replacement Registry Annual ReportArthroplasty Today, 2023
- New-Generation Low-Field Magnetic Resonance Imaging of Hip Arthroplasty Implants Using Slice Encoding for Metal Artifact CorrectionInvestigative Radiology, 2022
- Factors Independently Associated With Complications and Length of Stay after Hip ArthroplastyThe Journal of Arthroplasty, 2012
- Imaging near metal with a MAVRIC‐SEMAC hybridMagnetic Resonance in Medicine, 2010
- Magnetic resonance imaging near metal implantsJournal of Magnetic Resonance Imaging, 2010
- SEMAC: Slice encoding for metal artifact correction in MRIMagnetic Resonance in Medicine, 2009
- A multispectral three‐dimensional acquisition technique for imaging near metal implantsMagnetic Resonance in Medicine, 2009