Comparison of three differently shaped ROIs in free breathing breast radiotherapy setup using surface guidance with AlignRT®
Authors:
Open Access
- 1 January 2021
- journal article
- research article
- Published by VM Media Group sp. z o.o in Reports of Practical Oncology and Radiotherapy
- Vol. 26 (4) , 545-552
Abstract
Background: Setup accuracy within adjuvant radiotherapy of breast cancer treated in free breathing is well studied, but a comparison of the typical regions of interest (ROI) used in surface guided radiation therapy (SGRT) does not exist. The aim of this study was to estimate the setup accuracy obtained with differently shaped ROls in SGRT. Materials and methods: A total of 573 orthogonal image pairs were analyzed from free breathing breast patients in two groups: positioning using AlignRT surface guidance system (Group A, n = 20), and setup using conventional laser and tattoo setup (Group L, n = 20). For SGRT, three different setup ROIs were used: a Breast-shaped, 0-shaped and T-shaped (8-0 and T-ROI). We evaluated the isocenter-, rotation-, pitch and arm position accuracy and residual errors for the chest wall and shoulder joint in kV orthogonal and tangential setup images with laser- or SGRT-based setup. Results: Less isocenter variance was found in Group A than in Group L Rotations and posture errors were larger in group L than in Group A (p <= 0.05). Rotation error was smaller with T-shaped ROI than with 0- or B-shape (p = 0.01-0.04). Conclusion: Setup with AlignRT (R) improves reproducibility compared to laser setup. Between the different ROI shapes only small differences were found in the patient posture or the isocenter position in the images. The T-ROI is recommended to set up the chest wall bony structure and an additional B-ROl may be used to fine-tune the soft tissue accuracy.Keywords
This publication has 17 references indexed in Scilit:
- Intrafractional baseline drift during free breathing breast cancer radiation therapyActa Oncologica, 2017
- Comparison of setup accuracy of three different image assessment methods for tangential breast radiotherapyJournal of Medical Radiation Sciences, 2016
- Improving the reproducibility of voluntary deep inspiration breath hold technique during adjuvant left-sided breast cancer radiotherapyActa Oncologica, 2016
- Residual position errors of lymph node surrogates in breast cancer adjuvant radiotherapy: Comparison of two arm fixation devices and the effect of arm position correctionMedical Dosimetry, 2016
- Should breathing adapted radiotherapy also be applied for right-sided breast irradiation?Acta Oncologica, 2015
- Estimation of optimal matching position for orthogonal kV setup images and minimal setup margins in radiotherapy of whole breast and lymph node areasReports of Practical Oncology and Radiotherapy, 2014
- Assessment of interfractional variation of the breast surface following conventional patient positioning for whole‐breast radiotherapyJournal of Applied Clinical Medical Physics, 2014
- Arm and shoulder morbidity following surgery and radiotherapy for breast cancerActa Oncologica, 2014
- Clinical evaluation of interfractional variations for whole breast radiotherapy using 3-dimensional surface imagingPractical Radiation Oncology, 2013
- Analysis of interfraction and intrafraction variation during tangential breast irradiation with an electronic portal imaging deviceInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2005