MLMarko Laaksomaa

Marko Laaksomaa

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Marko Laaksomaa has a total of 25 co-authors. Here are the top co-authors by number of shared publications:

  • Mika Kapanen

    Teiskontie 35, Tampere, Finland

    4 shared publications
  • Mika Kapanen

    Department of Oncology, Tampere University Hospital, PO BOX 2000, FI-33521 Tampere, Finland; Department of Medical Physics, Tampere University Hospital, PO BOX 2000, FI-33521 Tampere, Finland

    4 shared publications
  • Pirkko-Liisa Kellokumpu-Lehtinen

    Faculty of Medicine and Life Sciences, University of Tampere, Tampere, Finland

    4 shared publications
  • Simo Hyödynmaa

    Department of Medical Physics, Medical Imaging Center, Tampere University Hospital, P.O. Box 2000, FI-33521 Tampere, Finland

    4 shared publications
  • Pirkko-Liisa Kellokumpu-Lehtinen

    Department of Oncology, Tampere University Hospital (TAUH), PO Box 2000, FI-33521 Tampere, Finland; Faculty of Medicine and Life Sciences, University of Tampere, PO Box 607, FI-33101 Tampere, Finland

    3 shared publications
  • Simo Hyödynmaa

    Department of Medical Physics, Tampere University Hospital (TAUH), PO Box 2000, FI-33521 Tampere, Finland

    3 shared publications

Latest Publications

  • Open Access

    AlignRT®, Catalyst™ and RPM™ in locoregional radiotherapy of breast cancer with DIBH. Is IGRT still needed?

    by Marko Laaksomaa, Jenni Ahlroth, Kiira Pynnönen, Anna Murtola, Maija Elina Rossi

    Background: In locoregional radiotherapy of breast cancer with deep inspiration breath hold (DIBH), setup accuracy may depend on hospital protocol. At present, comparison between different positioning devices is challenging due to differing hospital protocols. The aim of this study was to evaluate the setup accuracy obtained with surface-guided radiation therapy (SGRT; AlignRT®, Catalyst™) or with lasers and real-time position management (RPM™) in DIBH. Materials and methods: A total of 1692 image pairs were analyzed in three groups: positioning using AlignRT® surface guidance system (Group A, n = 45), Catalyst™ (Group C, n = 50) and conventional lasers and tattoos (Group L, n = 46). We evaluated residual errors for the bony chest wall, th1 and humeral head in kV images with laser- or SGRT-based setup with and without daily image-guided radiation therapy (IGRT). Results: Less isocenter variance was found in Group A than in Group L or C (p ≤ 0.05) and in Group C than in L (p = 0.02–0.6). With SGRT only, the smallest random rotation error was found in Group A (p = 0.01). With daily IGRT, only a small difference was found for residual errors between the groups. Conclusion: Setup with SGRT improves the isocenter reproducibility compared to lasers and RPM™. Only small differences were found in setup accuracy between the SGRT devices. Due to improved isocenter accuracy, daily orthogonal IGRT is suggested in all the groups.  Background: In locoregional radiotherapy of breast cancer with deep inspiration breath hold (DIBH), setup accuracy may depend on hospital protocol. At present, comparison between different positioning devices is challenging due to differing hospital protocols. The aim of this study was to evaluate the setup accuracy obtained with surface-guided radiation therapy (SGRT; AlignRT®, Catalyst™) or with lasers and real-time position management (RPM™) in DIBH. Materials and methods: A total of 1692 image pairs were analyzed in three groups: positioning using AlignRT® surface guidance system (Group A, n = 45), Catalyst™ (Group C, n = 50) and conventional lasers and tattoos (Group L, n = 46). We evaluated residual errors for the bony chest wall, th1 and humeral head in kV images with laser- or SGRT-based setup with and without daily image-guided radiation therapy (IGRT). Results: Less isocenter variance was found in Group A than in Group L or C (p ≤ 0.05) and in Group C than in L (p = 0.02–0.6). With SGRT only, the smallest random rotation error was found in Group A (p = 0.01). With daily IGRT, only a small difference was found for residual errors between the groups. Conclusion: Setup with SGRT improves the isocenter reproducibility compared to lasers and RPM™. Only small differences were found in setup accuracy between the SGRT devices. Due to improved isocenter accuracy, daily orthogonal IGRT is suggested in all the groups. 


  • Open Access

    Comparison of three differently shaped ROIs in free breathing breast radiotherapy setup using surface guidance with AlignRT®

    by Marko Laaksomaa, Torsten Moser, Julia Kritz, Kiira Pynnönen, Maija Rossi

    Background: Setup accuracy within adjuvant radiotherapy of breast cancer treated in free breathing is well studied, but a comparison of the typical regions of interest (ROI) used in surface guided radiation therapy (SGRT) does not exist. The aim of this study was to estimate the setup accuracy obtained with differently shaped ROls in SGRT. Materials and methods: A total of 573 orthogonal image pairs were analyzed from free breathing breast patients in two groups: positioning using AlignRT surface guidance system (Group A, n = 20), and setup using conventional laser and tattoo setup (Group L, n = 20). For SGRT, three different setup ROIs were used: a Breast-shaped, 0-shaped and T-shaped (8-0 and T-ROI). We evaluated the isocenter-, rotation-, pitch and arm position accuracy and residual errors for the chest wall and shoulder joint in kV orthogonal and tangential setup images with laser- or SGRT-based setup. Results: Less isocenter variance was found in Group A than in Group L Rotations and posture errors were larger in group L than in Group A (p <= 0.05). Rotation error was smaller with T-shaped ROI than with 0- or B-shape (p = 0.01-0.04). Conclusion: Setup with AlignRT (R) improves reproducibility compared to laser setup. Between the different ROI shapes only small differences were found in the patient posture or the isocenter position in the images. The T-ROI is recommended to set up the chest wall bony structure and an additional B-ROl may be used to fine-tune the soft tissue accuracy.


  • Effects of multiple breath hold reproducibility on treatment localization and dosimetric accuracy in radiotherapy of left-sided breast cancer with voluntary deep inspiration breath hold technique

    by Mika Kapanen, Marko Laaksomaa, Jani Pehkonen, Mikko Haltamo, Helmi Luukkanen, Turkka Lehtonen, Simo Hyödynmaa, Pirkko-Liisa Kellokumpu-Lehtinen


  • Residual position errors of lymph node surrogates in breast cancer adjuvant radiotherapy: Comparison of two arm fixation devices and the effect of arm position correction

    by Mika Kapanen, Marko Laaksomaa, Tanja Skyttä, Mikko Haltamo, Jani Pehkonen, Turkka Lehtonen, Pirkko-Liisa Kellokumpu-Lehtinen, Simo Hyödynmaa


  • Effects of remedies made in patient setup process on residual setup errors and margins in head and neck cancer radiotherapy based on 2D image guidance

    by Mika Kapanen, Marko Laaksomaa, Tapio Tulijoki, Pirkko-Liisa Kellokumpu-Lehtinen, Simo Hyödynmaa

    Patient setup errors were aimed to be reduced in radiotherapy (RT) of head-and-neck (H&N) cancer. Some remedies in patient setup procedure were proposed for this purpose. RT of H&N cancer has challenges due to patient rotation and flexible anatomy. Residual position errors occurring in treatment situation and required setup margins were estimated for relevant bony landmarks after the remedies made in setup process and compared with previous results. The formation process for thermoplastic masks was improved. Also image matching was harmonized to the vertebrae in the middle of the target and a 5 mm threshold was introduced for immediate correction of systematic errors of the landmarks. After the remedies, residual position errors of bony landmarks were retrospectively determined from 748 orthogonal X-ray images of 40 H&N cancer patients. The landmarks were the vertebrae C1-2, C5-7, the occiput bone and the mandible. The errors include contributions from patient rotation, flexible anatomy and inter-observer variation in image matching. Setup margins (3D) were calculated with the Van Herk formula. Systematic residual errors of the landmarks were reduced maximally by 49.8% (p ≤ 0.05) and the margins by 3.1 mm after the remedies. With daily image guidance the setup margins of the landmarks were within 4.4 mm, but larger margins of 6.4 mm were required for the mandible. Remarkable decrease in the residual errors of the bony landmarks and setup margins were achieved through the remedies made in the setup process. The importance of quality assurance of the setup process was demonstrated.


  • Open Access

    Determination of the optimal matching position for setup images and minimal setup margins in adjuvant radiotherapy of breast and lymph nodes treated in voluntary deep inhalation breath-hold

    by Marko Laaksomaa, Mika Kapanen, Mikko Haltamo, Tanja Skyttä, Seppo Peltola, Simo Hyödynmaa, Pirkko-Liisa Kellokumpu-Lehtinen

    Adjuvant radiotherapy (RT) of left-sided breast cancer is increasingly performed in voluntary deep inspiration breath-hold (vDIBH). The aim of this study was to estimate the reproducibility of breath-hold level (BHL) and to find optimal bony landmarks for matching of orthogonal setup images to minimise setup margins. 1067 sets of images with an orthogonal setup and tangential field from 67 patients were retrospectively analysed. Residual position errors were determined in the tangential treatment field images for different matches of the setup images. Variation of patient posture and BHL were analysed for position errors of the vertebrae, clavicula, ribs and sternum in the setup and tangential field images. The BHL was controlled with a Varian RPM® system. Setup margins were calculated using the van Herk’s formula. Patients who underwent lymph node irradiation were also investigated. For the breast alone, the midway compromise of the ribs and sternum was the best general choice for matching of the setup images. The required margins were 6.5 mm and 5.3 mm in superior-inferior (SI) and lateral/anterior-posterior (LAT/AP) directions, respectively. With the individually optimised image matching position also including the vertebrae, slightly smaller margins of 6.0 mm and 4.8 mm were achieved, respectively. With the individually optimised match, margins of 7.5 mm and 10.8 mm should be used in LAT and SI directions, respectively, for the lymph node regions. These margins were considered too large. The reproducibility of the BHL was within 5 mm in the AP direction for 75% of patients. The smallest setup margins were obtained when the matching position of the setup images was individually optimised for each patient. Optimal match for the breast alone is not optimal for the lymph node region, and, therefore, a threshold of 5 mm was introduced for residual position errors of the sternum, upper vertebrae, clavicula and chest wall to retain minimal setup margins of 5 mm. Because random interfraction variation in patient posture was large, we recommend daily online image guidance. The BHL should be verified with image guidance.


  • Estimation of optimal matching position for orthogonal kV setup images and minimal setup margins in radiotherapy of whole breast and lymph node areas

    by Marko Laaksomaa, Mika Kapanen, Tanja Skyttä, Seppo Peltola, Simo Hyödynmaa, Pirkko-Liisa Kellokumpu-Lehtinen

    The aim was to find an optimal setup image matching position and minimal setup margins to maximally spare the organs at risk in breast radiotherapy. Radiotherapy of breast cancer is a routine task but has many challenges. We investigated residual position errors in whole breast radiotherapy when orthogonal setup images were matched to different bony landmarks. A total of 1111 orthogonal setup image pairs and tangential field images were analyzed retrospectively for 50 consecutive patients. Residual errors in the treatment field images were determined by matching the orthogonal setup images to the vertebrae, sternum, ribs and their compromises. The most important region was the chest wall as it is crucial for the dose delivered to the heart and the ipsilateral lung. Inter-observer variation in online image matching was investigated. The best general image matching position was the compromise of the vertebrae, ribs and sternum, while the worst position was the vertebrae alone (p ≤ 0.03). The setup margins required for the chest wall varied from 4.3 mm to 5.5 mm in the lung direction while in the superior-inferior (SI) direction the margins varied from 5.1 mm to 7.6 mm. The inter-observer variation increased the minimal margins by approximately 1 mm. The margin of the lymph node areas should be at least 4.8 mm. Setup margins can be reduced by proper selection of a matching position for the orthogonal setup images. To retain the minimal margins sufficient, systematic error of the chest wall should not exceed 4 mm in the tangential field image.


  • Evaluation of overall setup accuracy and adequate setup margins in pelvic image-guided radiotherapy: Comparison of the male and female patients

    by Marko Laaksomaa, Mika Kapanen, Tapio Tulijoki, Seppo Peltola, Simo Hyödynmaa, Pirkko-Liisa Kellokumpu-Lehtinen


  • Open Access

    Estimation of adequate setup margins and threshold for position errors requiring immediate attention in head and neck cancer radiotherapy based on 2D image guidance

    by Mika Kapanen, Marko Laaksomaa, Tapio Tulijoki, Seppo Peltola, Tuija Wigren, Simo Hyödynmaa, Pirkko-Liisa Kellokumpu-Lehtinen