Seven-year outcomes after surgical aortic valve replacement with a stented bovine pericardial bioprosthesis in over 1100 patients: a prospective multicentre analysis
Open Access
- 20 November 2024
- journal article
- research article
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 67 (1)
Abstract
Safety, efficacy, and durability are important considerations when selecting a bioprosthesis for aortic valve replacement (AVR). This study assessed 7-year clinical outcomes and haemodynamic performance of the Avalus bioprosthesis. Patients indicated for surgical AVR were enrolled in this prospective, nonrandomized trial, conducted across 39 sites globally. The primary end-point of this analysis was freedom from surgical explant or percutaneous valve-in-valve reintervention due to structural valve deterioration (SVD) at 7 years of follow-up, determined using Kaplan–Meier (KM) analysis. We also evaluated a composite end-point of SVD or severe haemodynamic dysfunction (SHD) requiring reintervention. Survival, valve-related safety events, and haemodynamic performance were assessed. Deaths and safety events were adjudicated by an independent clinical events committee. A total of 1132 patients underwent surgical AVR. Mean age was 70 years; 854 patients (75%) were men. Mean STS risk of mortality was 2.0 ± 1.4%, and 659 patients (58%) had a NYHA classification of I/II. One or more concomitant procedures were performed in 577 patients (51%). At 7 years, the Kaplan–Meier rate of freedom from SVD/SHD requiring reintervention was 1.2% (0.5–2.5%) with no cases adjudicated as SVD. The survival rate was 82.6% (79.5–85.0%). The KM event rate was 5.7% (4.3–7.7%) for reintervention, 6.3% (4.9–8.3%) for endocarditis, and 0.4% (0.1–1.1%) for valve thrombosis. Mean aortic gradient, dimensionless velocity index, and effective orifice area were 13.8 ± 5.9 mmHg, 0.42 ± 0.09, and 1.99 ± 0.53 cm2, respectively. This analysis demonstrated excellent durability of the Avalus valve with good clinical outcomes and stable haemodynamic performance through 7 years of follow-up. www.clinicaltrials.gov ID: NCT02088554Keywords
Funding Information
- Medtronic
This publication has 14 references indexed in Scilit:
- Current definitions of hemodynamic structural valve deterioration after bioprosthetic aortic valve replacement lack consistencyJTCVS Open, 2024
- Seven-year outcomes following aortic valve replacement with a novel tissue bioprosthesisThe Journal of Thoracic and Cardiovascular Surgery, 2023
- Long-term durability after surgical aortic valve replacement with the Trifecta and the Intuity valve—a comparative analysisEuropean Journal of Cardio-Thoracic Surgery, 2021
- Doppler Velocity Index Outcomes Following Surgical or Transcatheter Aortic Valve Replacement in the PARTNER TrialsJACC: Cardiovascular Interventions, 2021
- Valve Academic Research Consortium 3: Updated Endpoint Definitions for Aortic Valve Clinical ResearchJACC, 2021
- One-year outcomes associated with a novel stented bovine pericardial aortic bioprosthesisThe Journal of Thoracic and Cardiovascular Surgery, 2018
- Recommendations for the imaging assessment of prosthetic heart valves: a report from the European Association of Cardiovascular Imaging endorsed by the Chinese Society of Echocardiography, the Inter-American Society of Echocardiography, and the Brazilian Department of Cardiovascular Imaging†European Heart Journal - Cardiovascular Imaging, 2016
- Recommendations for Evaluation of Prosthetic Valves With Echocardiography and Doppler UltrasoundJournal of the American Society of Echocardiography, 2009
- Guidelines for reporting mortality and morbidity after cardiac valve interventionsEuropean Journal of Cardio-Thoracic Surgery, 2008
- Aortic valve replacement with Toronto SPV bioprosthesis: Optimal patient survival but suboptimal valve durabilityThe Journal of Thoracic and Cardiovascular Surgery, 2008