SISaki Ito

Saki Ito

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Saki Ito has a total of 136 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Cardiac mechanical efficiency in patients with cardiogenic shock

    by Kristoffer Berg-Hansen, Oskar Kjærgaard Hørsdal, Henrik Wiggers, Roni Nielsen, Saki Ito, Barry A Borlaug, Dustin Hillerson, Jacob C Jentzer

    Aims: Cardiogenic shock (CS) is characterized by impaired left ventricular (LV) mechanical performance and adverse remodelling. We evaluated whether transthoracic echocardiography (TTE)-derived modified cardiac efficiency (mCE), integrating stroke work and residual LV volume, is associated with short- and long-term mortality in CS and whether its prognostic value differs by shock aetiology. Methods and results: In this retrospective cohort study, consecutive adults admitted with CS to the cardiac intensive care unit at Mayo Clinic (2007–2018) were included if TTE was performed within 24 h. mCE was calculated as (stroke volume × estimated LV end-systolic pressure) divided by LV end-systolic volume and categorized into quartiles. Primary outcome was in-hospital mortality; secondary outcome was 1-year mortality. Multivariable logistic and Cox models adjusted for illness severity, comorbidity burden, shock aetiology, cardiac arrest, vasoactive therapy, and mechanical circulatory support. Among 667 patients, median mCE was 48 mmHg (IQR 32–74). In-hospital mortality was 28% and increased stepwise across decreasing mCE quartiles. The lowest quartile had a 2.5-fold higher adjusted odds of in-hospital death (OR 2.53; 95%CI: 1.49–4.37; P < 0.001). One-year mortality was 41%; the lowest quartile had a two-fold higher adjusted hazard of death (HR 2.05; 95%CI: 1.45–2.89; P < 0.001). Associations were stronger in acute coronary syndrome-related CS (interaction P = 0.035 for in-hospital; P = 0.015 for 1-year). Within the lowest quartile, reduced systolic pressure further amplified mortality risk. Conclusion: Early TTE-derived mCE was independently associated with short- and long-term mortality in CS, particularly in acute coronary syndrome-related CS, and captured the interaction between ventricular remodelling and mechanical performance underlying high-risk phenotypes.


  • Open Access

    Left Ventricular Outflow Tract Diameter Variability and Prosthesis-Patient Mismatch: A Simulation Study

    by J W Taco Boltje, Bart J J Velders, Joseph F Sabik, Jae K Oh, Saki Ito, Robert J M Klautz, Michiel D Vriesendorp

    A recent discussion that highlighted the differences between the reported effective orifice area and corresponding incidence of prosthesis-patient mismatch within the 1- and 7-year results of the PERIcardial SurGical AOrtic Valve ReplacemeNt (PERIGON) Trial of the Avalus valve has once again emphasized the instability of such measurements. The effective orifice area, calculated using the continuity equation through measurements of the left ventricular outflow tract diameter, is highly susceptible to measurement variability, as previously demonstrated in literature through both intra- and interobserver variability. To illustrate this problem, a simulation was performed in which the left ventricular outflow tract diameter was systematically altered by −2 mm, −1 mm, 0 mm, +1 mm, and +2 mm. Subsequently, the proportion of severe prosthesis-patient mismatch was recalculated and varied between 13.3%, 6.2%, 3.1% (original), 1.2%, and 0.3%, respectively. These findings demonstrate that small but clinically realistic variability in left ventricular outflow tract measurements can significantly affect the presence of prosthesis-patient mismatch. A measurement variability of 1 mm can nearly double or halve the prevalence of severe prosthesis-patient mismatch. This illustrates that prosthesis-patient mismatch, in its current form, is highly unstable and that indexed effective orifice area-based prosthesis-patient mismatch should not be used in isolation.

  • Optimal Left Atrium Strain Acquisition and Measurement in Clinical Practice

    by Saki Ito, Victoria R. Jones, Michael D. Martineau, Joshua G. Fosland, Noweeda N. Mirza, Cristina Pislaru, Garvan C. Kane, Jeremy J. Thaden

  • Reply

    by Saki Ito, Jae K. Oh, Hector I. Michelena, Alexander C. Egbe, Heidi M. Connolly, Patricia A. Pellikka, Vuyisile T. Nkomo, Bradley R. Lewis, William R. Miranda

  • Impact of Transcatheter or Surgical Aortic Valve Performance on 5-Year Outcomes in Patients at ≥ Intermediate Risk

    by Steven J. Yakubov, Nicolas M. Van Mieghem, Jae K. Oh, Saki Ito, Kendra J. Grubb, Daniel O’HAir, John K. Forrest, Hemal Gada, Mubashir Mumtaz, G. Michael Deeb, et al.


  • Global longitudinal strain is a predictor of mortality in patients with cardiogenic shock

    by Kristoffer Berg-Hansen, Saki Ito, Jae Oh, Jeong Hoon Yang, Henrik Wiggers, Jacob C Jentzer

    Aims: Cardiogenic shock (CS) is a critical manifestation of severe cardiac dysfunction, necessitating precise evaluation of left ventricular (LV) function by transthoracic echocardiography. The prognostic value of global longitudinal strain (GLS) has not been examined in patients with CS. Therefore, we aimed to assess the prognostic significance of GLS in patients with CS. Methods and results: This was a retrospective study of patients with CS from 2007 to 2018 who had a transthoracic echocardiography performed within 24 h of admission. GLS was measured, and conventional parameters were obtained. LV dysfunction was categorized by GLS: > 9.7% (Quartile 1), 7.0% < GLS ≤ 9.7% (Quartile 2), 5.0% < GLS ≤ 7.0% (Quartile 3), and ≤5.0% (Quartile 4). Outcomes included in-hospital and 1-year all-cause mortality. Among 623 patients with CS with the median LVEF of 31% [inter-quartile range (IQR): 24–41%] and the median GLS of 7.0% (IQR: 5.0–9.7%), in-hospital mortality was 29%. Mortality increased across GLS quartiles: Quartile 1: 17%; Quartile 2: 22%; Quartile 3: 35%; and Quartile 4: 42%. GLS remained the only independent echocardiographic predictor of in-hospital mortality after adjusting for clinical covariates (adjusted odds ratio: 1.23 per 1% decrease, 95% confidence interval: 1.04–1.46, P = 0.015). GLS independently predicted 1-year all-cause mortality (P < 0.001). The prognostic value of GLS was superior in cases with acute coronary syndrome. A classification and regression tree analysis identified GLS as the most important echocardiographic variable for predicting in-hospital mortality. Conclusion: GLS independently predicted short- and long-term mortality in patients with CS, surpassing conventional echocardiographic parameters in prognostic value, supporting its potential role in risk stratification in this population.


  • Open Access

    Seven-year outcomes after surgical aortic valve replacement with a stented bovine pericardial bioprosthesis in over 1100 patients: a prospective multicentre analysis

    by Joseph F Sabik, Vivek Rao, Francois Dagenais, Michael G Moront, Michael J Reardon, Himanshu J Patel, Jae K Oh, Shinichi Fukuhara, Louis Labrousse, Ralf Günzinger, et al.

    Safety, efficacy, and durability are important considerations when selecting a bioprosthesis for aortic valve replacement (AVR). This study assessed 7-year clinical outcomes and haemodynamic performance of the Avalus bioprosthesis. Patients indicated for surgical AVR were enrolled in this prospective, nonrandomized trial, conducted across 39 sites globally. The primary end-point of this analysis was freedom from surgical explant or percutaneous valve-in-valve reintervention due to structural valve deterioration (SVD) at 7 years of follow-up, determined using Kaplan–Meier (KM) analysis. We also evaluated a composite end-point of SVD or severe haemodynamic dysfunction (SHD) requiring reintervention. Survival, valve-related safety events, and haemodynamic performance were assessed. Deaths and safety events were adjudicated by an independent clinical events committee. A total of 1132 patients underwent surgical AVR. Mean age was 70 years; 854 patients (75%) were men. Mean STS risk of mortality was 2.0 ± 1.4%, and 659 patients (58%) had a NYHA classification of I/II. One or more concomitant procedures were performed in 577 patients (51%). At 7 years, the Kaplan–Meier rate of freedom from SVD/SHD requiring reintervention was 1.2% (0.5–2.5%) with no cases adjudicated as SVD. The survival rate was 82.6% (79.5–85.0%). The KM event rate was 5.7% (4.3–7.7%) for reintervention, 6.3% (4.9–8.3%) for endocarditis, and 0.4% (0.1–1.1%) for valve thrombosis. Mean aortic gradient, dimensionless velocity index, and effective orifice area were 13.8 ± 5.9 mmHg, 0.42 ± 0.09, and 1.99 ± 0.53 cm2, respectively. This analysis demonstrated excellent durability of the Avalus valve with good clinical outcomes and stable haemodynamic performance through 7 years of follow-up. www.clinicaltrials.gov ID: NCT02088554


  • Open Access

    Three-Year Outcomes Following TAVR in Younger (<75 Years) Low-Surgical-Risk Severe Aortic Stenosis Patients

    by Thomas Modine, Didier Tchétché, Nicolas M. Van Mieghem, G. Michael Deeb, Stanley J. Chetcuti, Steven J. Yakubov, Paul Sorajja, Hemal Gada, Mubashir Mumtaz, Basel Ramlawi, et al.

    BACKGROUND: Transcatheter aortic valve replacement (TAVR) is an alternative to surgery in patients with severe aortic stenosis, but data are limited on younger, low-risk patients. This analysis compares outcomes in low-surgical-risk patients aged P =0.241). Although there was no difference between TAVR and surgery in all-cause mortality, the incidence of disabling stroke was lower with TAVR (0.6%) than surgery (2.9%; P =0.019), while surgery was associated with a lower incidence of pacemaker implantation (7.1%) compared with TAVR (21.0%; P P =0.962) were low in both groups. Valve performance was significantly better with TAVR than surgery with lower mean aortic gradients ( P P <0.001). Rates of valve thrombosis and endocarditis were similar between groups. There were no significant differences in rates of residual ≥moderate paravalvular regurgitation. CONCLUSIONS: Low-risk patients <75 years treated with supra-annular, self-expanding TAVR had comparable 3-year all-cause mortality and lower disabling stroke compared with patients treated with surgery. There was significantly better valve performance in patients treated with TAVR. REGISTRATION: URL: https://clinicaltrials.gov ; Unique identifier: NCT02701283.


  • High-Gradient Aortic Stenosis With Valve Area >1.0 cm2

    by Saki Ito, Jae K. Oh, Hector I. Michelena, Alexander C. Egbe, Heidi M. Connolly, Patricia A. Pellikka, Vuyisile T. Nkomo, Bradley R. Lewis, William R. Miranda


  • Examining the typical hemodynamic performance of nearly 3000 modern surgical aortic bioprostheses

    by Robert J M Klautz, Vivek Rao, Michael J Reardon, G Michael Deeb, Francois Dagenais, Michael G Moront, Stephen H Little, Louis Labrousse, Himanshu J Patel, Saki Ito, et al.

    The objective of this analysis was to assess the normal haemodynamic performance of contemporary surgical aortic valves at 1 year postimplant in patients undergoing surgical aortic valve replacement for significant valvular dysfunction. By pooling data from 4 multicentre studies, this study will contribute to a better understanding of the effectiveness of surgical aortic valve replacement procedures, aiding clinicians and researchers in making informed decisions regarding valve selection and patient management. Echocardiograms were assessed by a single core laboratory. Effective orifice area, dimensionless velocity index, mean aortic gradient, peak aortic velocity and stroke volume were evaluated. The cohort included 2958 patients. Baseline age in the studies ranged from 70.1 ± 9.0 to 83.3 ± 6.4 years, and Society of Thoracic Surgeons risk of mortality was 1.9 ± 0.7 to 7.5 ± 3.4%. Twenty patients who had received a valve model implanted in fewer than 10 cases were excluded. Ten valve models (all tissue valves; n = 2938 patients) were analysed. At 1 year, population mean effective orifice area ranged from 1.46 ± 0.34 to 2.12 ± 0.59 cm2, and dimensionless velocity index, from 0.39 ± 0.07 to 0.56 ± 0.15. The mean gradient ranged from 8.6 ± 3.4 to 16.1 ± 6.2 mmHg with peak aortic velocity of 1.96 ± 0.39 to 2.65 ± 0.47 m/s. Stroke volume was 75.3 ± 19.6 to 89.8 ± 24.3 ml. This pooled cohort is the largest to date of contemporary surgical aortic valves with echocardiograms analysed by a single core lab. Overall haemodynamic performance at 1 year ranged from good to excellent. These data can serve as a benchmark for other studies and may be useful to evaluate the performance of bioprosthetic surgical valves over time. NCT02088554, NCT02701283, NCT01586910 and NCT01531374.