We determine experimentally the accuracy of pulsed photothermal radiometric (PPTR) temperature depth profiling in water-based samples. We use custom tissue phantoms composed of agar gel layers separated by very thin absorbing layers. Two configurations of the acquisition system are compared, one using the customary spectral band of the InSb radiation detector (3.0–5.5 μm) and the other with a spectrally narrowed acquisition band (4.5–5.5 μm). The laser-induced temperature depth profiles are reconstructed from measured radiometric signals using a custom minimization algorithm. The results correlate very well with phantom geometry as determined by optical coherence tomography (OCT) and histology in all evaluated samples. Determination of the absorbing layer depth shows good repeatability with spatial resolution decreasing with depth. Spectral filtering improves the accuracy and resolution, especially for shallow absorption layers (∼120 μm) and more complex structures (e.g., with two absorbing layers). The average full width at half maximum (FWHM) of the temperature peaks equals 23% of the layer depth.Keywords
This publication has 21 references indexed in Scilit:
- Optimal cryogen spray cooling parameters for pulsed laser treatment of port wine stainsLasers in Surgery and Medicine, 2000
- Accuracy of subsurface temperature distributions computed from pulsed photothermal radiometryPhysics in Medicine & Biology, 1998
- Non-invasive determination of port wine stain anatomy and physiology for optimal laser treatment strategiesPhysics in Medicine & Biology, 1997
- Limitations in measurement of subsurface temperatures using pulsed photothermal radiometryJournal of Biomedical Optics, 1997
- Depth determination of chromophores in human skin by pulsed photothermal radiometryApplied Optics, 1996
- Depth profiling of laser-heated chromophores in biological tissues by pulsed photothermal radiometryJournal of the Optical Society of America A, 1995
- Analysis of layered scattering materials by pulsed photothermal radiometry: application to photon propagation in tissueApplied Optics, 1995
- In-vivo opto-thermal measurement of epidermal thicknessJournal de Physique IV, 1994
- Pulsed photothermal radiometry of port-wine-stain lesionsApplied Optics, 1993
- Pulsed photothermal radiometry for depth profiling of layered mediaApplied Physics Letters, 1987