JNJ. Stuart Nelson

J. Stuart Nelson

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


J. Stuart Nelson has a total of 61 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Optical and acoustic scattering in cutaneous neurofibromas: Implications for early detection

    by Wangcun Jia, Nitesh Katta, Gordon T. Kennedy, Junsoo Lee, Emily Nguyen, Oswald Lai, Yurie Jeong, Rachel Elsanadi, Feben Messele, James E. Johnson, et al.

  • Open Access

    Unique Clinical Aspects of Nasal Scarring

    by Benjamin P. Caughlin, Christian Barnes, J. Stuart Nelson, Brian J.F. Wong


  • PAPI-V: Performance Monitoring for Virtual Machines

    by Matthew Johnson, Heike McCraw, Shirley Moore, Phil Mucci, John Nelson, Dan Terpstra, Vince Weaver, Tushar Mohan

    This paper describes extensions to the PAPI hardware counter library for virtual environments, called PAPI-V. The extensions support timing routines, I/O measurements, and processor counters. The PAPI-V extensions will allow application and tool developers to use a familiar interface to obtain relevant hardware performance monitoring information in virtual environments.


  • Open Access

    Pulsed photothermal temperature profiling of agar tissue phantoms

    by Matija Milanič, Boris Majaron, J. Stuart Nelson

    We determine experimentally the accuracy of pulsed photothermal radiometric (PPTR) temperature depth profiling in water-based samples. We use custom tissue phantoms composed of agar gel layers separated by very thin absorbing layers. Two configurations of the acquisition system are compared, one using the customary spectral band of the InSb radiation detector (3.0–5.5 μm) and the other with a spectrally narrowed acquisition band (4.5–5.5 μm). The laser-induced temperature depth profiles are reconstructed from measured radiometric signals using a custom minimization algorithm. The results correlate very well with phantom geometry as determined by optical coherence tomography (OCT) and histology in all evaluated samples. Determination of the absorbing layer depth shows good repeatability with spatial resolution decreasing with depth. Spectral filtering improves the accuracy and resolution, especially for shallow absorption layers (∼120 μm) and more complex structures (e.g., with two absorbing layers). The average full width at half maximum (FWHM) of the temperature peaks equals 23% of the layer depth.


  • Open Access

    Feasibility study of normal and septic tracheal imaging using optical coherence tomography

    by Woonggyu Jung, Jun Zhang, Reza Mina‐Araghi, Nevine Hanna, Matthew Brenner, J. Stuart Nelson, Zhongping Chen

    Background and Objectives: Optical coherence tomography (OCT) is an imaging technology that may be adapted for use with flexible fiberoptic bronchoscopy, potentially allowing it to play an important role in pulmonary diagnostics. The goal of this study was to evaluate the feasibility of OCT to image tracheal pathology.Study Design/Materials and Methods: Tracheas were harvested from normal and septic New Zealand White rabbits and imaged using OCT. Two delivery devices were employed. One was a moving stage with an objective lens and collimator, the other a linear scanning flexible fiberoptic catheter using a GRIN lens and prism for endoscopic OCT. After OCT images were obtained from normal and septic tracheas, the excised tissues were prepared for standard histologic examination. Areas imaged by OCT were compared with corresponding histology slides.Results: OCT images demonstrated in detail tracheal sub‐surface structures such as the epithelium, lamina propria, submucosa, and cartilage. The appearance of structures imaged by OCT corresponded very well with histologic pictures obtained by light microscopy. The OCT images from septic tracheas showed marked swelling of the mucosal and submucosal layers. Such pathology was equally imaged by either the moving stage or fiberoptic catheter for endoscopic OCT.Conclusions: OCT images of the trachea can distinguish many sub‐surface structural features usually requiring biopsy and light microscopy for visualization. Marked differences between normal and septic trachea were apparent in OCT images. In the future, OCT may be a valuable tool for evaluating tracheal pathology in situ with high image resolution. Lasers Surg. Med. 35:121–127, 2004.


  • Optimization of Cryogen Spray Cooling for Port Wine Stain Laser Therapy Using Photoacoustic Measurement of Epidermal Melanin

    by John A. Viator, Guillermo Aguilar, Steven L. Jacques, J. Stuart Nelson

    Treatment of vascular skin lesions, such as port wine stain (PWS) birthmarks, uses laser energy to thermally damage the hypervascular regions in the dermis. Delivery of sufficient laser energy to the dermis can be confounded by the more superficial epidermal melanin layer, a broadband optical absorber. Laser pulses directed at skin lesions may result in excessive heating and scarring of the epidermis, resulting also in limiting the energy available to treat the dermal lesion. Cryogen spray cooling is used to selectively cool the epidermis, allowing the use of higher laser fluences which cause thermal damage in the deeper lesion, while preventing hypertrophic scarring of the epidermis. In order to optimize cryogen cooling and laser pulse parameter for treatment, the depth profile of the epidermal melanin layer and vascular lesion must be known. We use a photoacoustic probe to determine this depth profile. A Q-switched Nd:YAG laser emitting 532 nm light pulses of 4 ns duration is used to excite acoustic waves in epidermal melanin and hemoglobin in the vascular lesions via a miniature probe incorporating a piezoelectric detector. We used acoustic propagation time to determine the spatial relationship of the absorbing structures, thereby giving the necessary means to determine cryogen spurt and laser pulse timing. We present a finite difference thermal model along with data from tissue phantoms showing the effectiveness of the photoacoustic method.


  • Test Channels for Flow Characterization of Processed Plastic Microchannels

    by Yandong Chen, Zhongping Chen, Yonghua Zhao, J. Stuart Nelson, Mark Bachman, Yuh-Min Chiang, Charles Chu, G. P. Li


  • Cryogen Spray Cooling during Nd:YAG Laser Treatment of Hemangiomas A Preliminary Animal Model Study

    by Wendy L. Hoffman, Bahman Anvari, Samireh Said, Samuel B. Tanenbaum, Lih-Huei Liaw, Thomas Milner, Stuart J. Nelson

    Successful laser treatment of hemangiomas requires selective photothermal destruction of dilated cutaneous vessels without damaging the overlying epidermis. Delivering a short cryogen spurt, on the order of milliseconds, has been shown to result in localized cooling of the superficial skin structures during laser irradiation. The purpose of this study was to examine the effectiveness of cryogen spray cooling (CSC) in protecting superficial tissue structures during continuous Nd:YAG laser irradiation of an in vivo model hemangioma. The highly vascularized chicken comb was selected as the animal model for hemangiomas. The Nd:YAG laser irradiation ranged from 2.6 to 35.1 J/mm2. A feedback system utilizing infrared radiometry monitored the comb surface temperature and controlled delivery time of the cryogen spurt. When comb surface temperature during laser irradiation reached 36-42 degrees C, a 30-100 msec cryogen spurt was delivered. Animals were euthanized 1 hour to 21 days following each experiment. Gross and histologic analyses were performed. Nd:YAG laser irradiation resulted in deep (up to 6.1 mm) tissue photocoagulation, while CSC preserved the overlying epidermis and papillary dermis. The results demonstrate that CSC is effective in protecting the epidermis and papillary dermis, while achieving deep tissue photocoagulation during Nd:YAG laser irradiation. Further pilot studies in humans appear warranted.


  • Compositional dependence of the luminescence of In0.49(AlyGa1−y)0.51P alloys near the direct–indirect band-gap crossover

    by J. S. Nelson, E. D. Jones, S. M. Myers, D. M. Follstaedt, H. P. Hjalmarson, J. E. Schirber, R. P. Schneider, J. E. Fouquet, V. M. Robbins, K. W. Carey

    A number of complementary experimental characterization tools and theoretical band structure methods were used to determine unambiguously the band-edge luminescence as a function of Al concentration, and to place an upper limit on the short-wavelength emission of InAlGaP alloys lattice matched to GaAs. In particular, the direct-to-indirect band-gap crossing has been determined by analyzing a series of metalorganic vapor-phase-epitaxy-grown In0.49(Aly Ga1−y )0.51P alloys lattice matched to GaAs with double-crystal x-ray analysis, Rutherford backscattering spectroscopy, pressure- and temperature-dependent photoluminescence, and transmission electron microscopy. The experimental measurements are compared to first-principles plane-wave pseudopotential band structure calculations for the ternary end points, InGaP and InAlP. The maximum room temperature direct band gap is found to be 2.24 eV, corresponding to an Al composition of y=0.52±0.02, in good agreement with the theoretical prediction of 0.58±0.05. © 1996 The American Physical Society.