Effect of Attenuation Mismatches in Time of Flight PET Reconstruction
Authors:
Preprint
Abstract
While the pursuit of better time resolution in positron emission tomography (PET) is rapidly evolving, little work has been performed on time of flight (TOF) image quality at high time resolution in the presence of modelling inconsistencies. This works focuses on the effect of using the wrong attenuation map in the system model, causing perturbations in the reconstructed radioactivity image. Previous work has usually considered the effects to be local to the area where there is attenuation mismatch, and has shown that the quantification errors in this area tend to reduce with improved time resolution. This publication shows however that errors in the PET image at a distance from the mismatch increase with time resolution. The errors depend on the reconstruction algorithm used. We quantify the errors in the hypothetical case of perfect time resolution for maximum likelihood reconstructions. In addition, we perform reconstructions on simulated and patient data. In particular, for respiratory-gated reconstructions from a wrong attenuation map, increased errors are observed with improved time resolutions in areas close to the lungs (e.g., from 13.3% in non-TOF to up to 20.9% at 200 ps in the left ventricle).Keywords
All Related Versions
This publication has 20 references indexed in Scilit:
- PET/MRI attenuation estimation in the lung: A review of past, present, and potential techniquesMedical Physics, 2019
- Issues in quantification of registered respiratory gated PET/CT in the lungPhysics in Medicine & Biology, 2017
- Evaluation of a direct motion estimation/correction method in respiratory-gated PET/MRI with motion-adjusted attenuationMedical Physics, 2017
- Multi-atlas attenuation correction supports full quantification of static and dynamic brain PET data in PET-MRPhysics in Medicine & Biology, 2017
- Impact of time-of-flight on indirect 3D and direct 4D parametric image reconstruction in the presence of inconsistent dynamic PET dataPhysics in Medicine & Biology, 2016
- The effect of respiratory induced density variations on non-TOF PET quantitation in the lungPhysics in Medicine & Biology, 2016
- Respiratory-Induced Errors in Tumor Quantification and Delineation in CT Attenuation-Corrected PET Images: Effects of Tumor Size, Tumor Location, and Respiratory Trace: A Simulation Study Using the 4D XCAT PhantomMolecular Imaging and Biology, 2013
- Time-of-flight PET data determine the attenuation sinogram up to a constantPhysics in Medicine & Biology, 2012
- Why is TOF PET reconstruction a more robust method in the presence of inconsistent data?Physics in Medicine & Biology, 2010
- User-guided 3D active contour segmentation of anatomical structures: Significantly improved efficiency and reliabilityNeuroImage, 2006