Multi-atlas attenuation correction supports full quantification of static and dynamic brain PET data in PET-MR
Open Access
- 14 March 2017
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 62 (7) , 2834-2858
Abstract
In simultaneous PET-MR, attenuation maps are not directly available. Essential for absolute radioactivity quantification, they need to be derived from MR or PET data to correct for gamma photon attenuation by the imaged object. We evaluate a multi-atlas attenuation correction method for brain imaging (MaxProb) on static [18F]FDG PET and, for the first time, on dynamic PET, using the serotoninergic tracer [18F]MPPF. A database of 40 MR/CT image pairs (atlases) was used. The MaxProb method synthesises subject-specific pseudo-CTs by registering each atlas to the target subject space. Atlas CT intensities are then fused via label propagation and majority voting. Here, we compared these pseudo-CTs with the real CTs in a leave-one-out design, contrasting the MaxProb approach with a simplified single-atlas method (SingleAtlas). We evaluated the impact of pseudo-CT accuracy on reconstructed PET images, compared to PET data reconstructed with real CT, at the regional and voxel levels for the following: radioactivity images; time-activity curves; and kinetic parameters (non-displaceable binding potential, BPND). On static [18F]FDG, the mean bias for MaxProb ranged between 0 and 1% for 73 out of 84 regions assessed, and exceptionally peaked at 2.5% for only one region. Statistical parametric map analysis of MaxProb-corrected PET data showed significant differences in less than 0.02% of the brain volume, whereas SingleAtlas-corrected data showed significant differences in 20% of the brain volume. On dynamic [18F]MPPF, most regional errors on BPND ranged from -1 to +3% (maximum bias 5%) for the MaxProb method. With SingleAtlas, errors were larger and had higher variability in most regions. PET quantification bias increased over the duration of the dynamic scan for SingleAtlas, but not for MaxProb. We show that this effect is due to the interaction of the spatial tracer-distribution heterogeneity variation over time with the degree of accuracy of the attenuation maps. This work demonstrates that inaccuracies in attenuation maps can induce bias in dynamic brain PET studies. Multi-atlas attenuation correction with MaxProb enables quantification on hybrid PET-MR scanners, eschewing the need for CT.Keywords
Funding Information
- Agence Nationale de la Recherche (ANR-10-IBHU-0003, project-11-EQPX-0026)
- ANRT / Siemens (CIFRE 2013/1092)
This publication has 39 references indexed in Scilit:
- Multi-contrast attenuation map synthesis for PET/MR scanners: assessment on FDG and Florbetapir PET tracersEuropean Journal of Nuclear Medicine and Molecular Imaging, 2015
- Patch‐based generation of a pseudo CT from conventional MRI sequences for MRI‐only radiotherapy of the brainMedical Physics, 2015
- Effect of scatter correction when comparing attenuation maps: Application to brain PET/MR2014
- Attenuation Correction Synthesis for Hybrid PET-MR Scanners: Application to Brain StudiesIEEE Transactions on Medical Imaging, 2014
- A comparison of CT- and MR-based attenuation correction in neurological PETEuropean Journal of Nuclear Medicine and Molecular Imaging, 2014
- Combined PET/MR imaging in neurology: MR-based attenuation correction implies a strong spatial bias when ignoring boneNeuroImage, 2014
- Performance Measurements of the Siemens mMR Integrated Whole-Body PET/MR ScannerJournal of Nuclear Medicine, 2011
- Toward Implementing an MRI-Based PET Attenuation-Correction Method for Neurologic Studies on the MR-PET Brain PrototypeJournal of Nuclear Medicine, 2010
- Method for transforming CT images for attenuation correction in PET/CT imagingMedical Physics, 2006
- Modeling [18F]MPPF Positron Emission Tomography Kinetics for the Determination of 5-Hydroxytryptamine(1A) Receptor Concentration with MultiinjectionJournal of Cerebral Blood Flow & Metabolism, 2002