Three-element phased-array coil for imaging of rat spinal cord at 7T
- 24 November 2008
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 60 (6) , 1498-1505
Abstract
To overcome some of the limitations of an implantable coil, including its invasive nature and limited spatial coverage, a three-element phased-array coil is described for high-resolution magnetic resonance imaging (MRI) of rat spinal cord. This coil allows imaging both thoracic and cervical segments of rat spinal cord. In the current design, coupling between the nearest neighbors was minimized by overlapping the coil elements. A simple capacitive network was used for decoupling the next neighbor elements. The dimensions of individual coils in the array were determined based on the signal-to-noise ratio (SNR) measurements performed on a phantom with three different surface coils. SNR measurements on a phantom demonstrated higher SNR for the phased array coil relative to two different volume coils. In vivo images acquired on rat spinal cord with our coil demonstrated excellent gray and white matter contrast. To evaluate the performance of the phased array coil under parallel imaging, g-factor maps were obtained for acceleration factors of 2 and 3. These simulations indicate that parallel imaging with an acceleration factor of 2 would be possible without significant image reconstruction-related noise amplifications.Keywords
Funding Information
- National Institutes of Health/National Institute of Neurological Disorders and Stroke (NS045624)
This publication has 23 references indexed in Scilit:
- Radiofrequency coils for magnetic resonance microscopyNMR in Biomedicine, 2008
- In vivo diffusion tensor imaging of the rat spinal cord at 9.4TJournal of Magnetic Resonance Imaging, 2008
- Noninvasive diffusion tensor imaging of evolving white matter pathology in a mouse model of acute spinal cord injuryMagnetic Resonance in Medicine, 2007
- Mouse MRI using phased‐array coilsNMR in Biomedicine, 2007
- Parallel imaging for NMR microscopy at 14.1 TeslaMagnetic Resonance in Medicine, 2005
- Parallel Imaging at High Field StrengthTopics in Magnetic Resonance Imaging, 2004
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- Design of Matching Networks for Low Noise PreamplifiersMagnetic Resonance in Medicine, 1995
- A method for in vivo high resolution MRI of rat spinal cord injuryMagnetic Resonance in Medicine, 1994