Sources of Variability in the Detection of Cerebral Emboli with Transcranial Doppler During Cardiac Surgery
- 3 April 2006
- journal article
- research article
- Published by Wiley in Journal of Neuroimaging
- Vol. 16 (2) , 126-132
Abstract
Objective. The application of intensity thresholds for embolus detection with transcranial Doppler (TCD) can exclude from analysis an unrecognized proportion of high‐intensity transient signals (HITS))whose intensities are below the threshold. The lack of consistent threshold criteria between clinical trials may explain part of the discrepancy in the reported HITS counts. We investigated the effect of choosing different thresholds on the sensitivity and specificity of detecting HITS during cardiopulmonary bypass (CPB). Methods. Two observers independently analyzed TCD recordings from 8 patients under CPB. Doppler signals were classified as true HITS, equivocal HITS, artifacts, and Doppler speckles according to preestablished criteria. The relative intensity of Doppler signals was measured by two different methods (TCD software vs manual). Receiver Operating Characteristic curves determined the optimal threshold for each of the two intensity methods. Results. Reviewers achieved agreement in 96% of 2190 Doppler signals (κ= 0.90). Relative intensities calculated with the TCD‐software method were 3 dB (95% CI: 3.0‐3.4) higher than the manual method. The optimal threshold was found at 10 dB (sensitivity: 99%; specificity: 90.8%) with the software method and at 7 dB with the manual method (sensitivity: 96%; specificity: 83%). The use of an intensity threshold 2 dB higher than the optimal increased the rejection of true HITS by 8% and 14%, respectively. Conclusions. Using intensity thresholds higher than the optimal for embolus detection decreases HITS counts. Choosing a threshold depends on the type of method used for measuring the signal intensity. Uniform threshold criteria and comparative studies between different Doppler devices are necessary for making clinical trials more comparable.Keywords
This publication has 24 references indexed in Scilit:
- Transcranial Doppler Characteristics of Different Embolic Materials During In Vivo TestingJournal of Neuroimaging, 2002
- Automatic Classification of HITS Into Artifacts or Solid or Gaseous Emboli by a Wavelet Representation Combined With Dual-Gate TCDStroke, 2001
- Consensus on Microembolus Detection by TCDStroke, 1998
- Alterations of Neuropsychological Function and Cerebral Glucose Metabolism After Cardiac Surgery Are Not Related Only to Intraoperative Microembolic EventsStroke, 1998
- Intercenter Agreement in Reading Doppler Embolic SignalsStroke, 1997
- Bigated Transcranial Doppler for the Detection of Clinically Silent Circulating Emboli in Normal Persons and Patients With Prosthetic Cardiac ValvesStroke, 1997
- Clinically Silent Microemboli in Patients With Artificial Prosthetic Aortic Valves Are Predominantly Gaseous and Not SolidStroke, 1997
- Differentiation between gaseous and formed embolic materials in vivo. Application in prosthetic heart valve patients.Stroke, 1994
- Differentiation between different pathological cerebral embolic materials using transcranial Doppler in an in vitro model.Stroke, 1993
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986