RRRosendo A. Rodriguez

Rosendo A. Rodriguez

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Rosendo A. Rodriguez has a total of 31 co-authors. Here are the top co-authors by number of shared publications:

  • Howard J. Nathan

    5 shared publications
  • Fraser Rubens

    Division of Cardiac Surgery, Department of Surgery, University of Ottawa Heart Institute, Ottawa, Ontario, Canada

    4 shared publications
  • Dean Belway

    Department of Cardiovascular Perfusion, University of Ottawa Heart Institute, Ottawa, Canada

    2 shared publications
  • Garry Cornel

    Department of Surgery, Division of Cardiac Surgery, Ottawa, Ontario, Canada

    2 shared publications
  • Howard J Nathan

    Department of Anesthesiology, Cardiac Division, University of Ottawa Heart Institute, Ottawa, Ontario, Canada

    2 shared publications
  • Marc Ruel

    Division of Cardiac Surgery, University of Ottawa Heart Institute, Ottawa, ON, Canada

    2 shared publications

Latest Publications

  • Predictors of Duration of Unconsciousness in Patients With Coma After Cardiac Surgery

    by Rosendo A. Rodriguez, Miguel Bussière, Michael Bourke, Thierry Mesana, Howard J. Nathan


  • Cerebral Emboli Detected by Transcranial Doppler During Cardiopulmonary Bypass Are Not Correlated With Postoperative Cognitive Deficits

    by Rosendo A. Rodriguez, Fraser D. Rubens, Denise Wozny, Howard J. Nathan

    Background and Purpose— High-intensity transient signals (HITS) are the transcranial Doppler representation of both air and solid cerebral emboli. We studied the frequency of HITS associated with different surgical maneuvers during cardiopulmonary bypass for coronary artery bypass graft surgery and their association with postoperative cognitive dysfunction (POCD). Methods— We combined 356 patients undergoing coronary artery bypass graft from 2 clinical trials who had both neuropsychological testing (before, 1 week and 3 months after surgery) and transcranial Doppler during cardiopulmonary bypass. HITS were grouped into periods that included: cannulation, cardiopulmonary bypass onset, aortic crossclamp-on, aortic crossclamp-off, side clamp-on, side clamp-off, and decannulation. POCD was defined by a decreased combined Z-score of at least 2.0 or reduction in Z-scores of at least 2.0 in 20% of the individual tests. Results— Incidence of POCD was 47.3% and 6.3% at 1 week and 3 months after surgery. There was no association between cardiopulmonary bypass counts of HITS and POCD at 1 week ( P =0.617) and 3 months ( P =0.110). No differences in HITS counts were identified at any of the surgical periods between patients with and without POCD. Factors affecting HITS counts were surgical period ( P P =0.012), cardiopulmonary bypass duration ( P =0.040), and clinical study ( P =0.048). Conclusions— Although cerebral microemboli have been implicated in the pathogenesis of POCD, in this study that included low-risk patients undergoing coronary artery bypass surgery, there was no demonstrable correlation between the counts of HITS and POCD.


  • Open Access

    Transcranial Doppler and acoustic pressure fluctuations for the assessment of cavitation and thromboembolism in patients with mechanical heart valves

    by Rosendo A. Rodriguez, Marc Ruel, Michel Labrosse, Thierry Mesana

    The formation and collapse of vapor-filled bubbles near a mechanical heart valve is called cavitation. Such microbubbles are suspected to have strong


  • Do Surface-Modifying Additive Circuits Reduce the Rate of Cerebral Microemboli During Cardiopulmonary Bypass?

    by Rosendo A. Rodriguez, Maura I. Watson, Howard J. Nathan, Fraser Rubens

    The objective of this study was to determine if surface-modifying additive (SMA) cardiopulmonary bypass (CPB) circuits are associated with a lower rate of cerebral microemboli during CPB compared with standard circuits. In a 2 × 2 factorial design, patients undergoing coronary artery bypass graft surgery were randomized to SMA or standard CPB circuits (with and without methyl-prednisolone). Transcranial Doppler was used to detect high-intensity transient signals (HITS) in both middle cerebral arteries. HITS were counted from onset to end of CPB. Intervals of interest were as follows: period 1, from CPB onset to aortic cross-clamping; period 2, from aortic cross-clamping to immediately before de-clamping; period 3, from aortic de-clamping to before aortic side-clamping; period 4, from the application of the aortic side clamp to immediately before the release of the side clamp; period 5, from aortic side clamp release to the end of CPB. There were 14 patients in each circuit group. No significant differences were found on the partial and total counts of HITS (medians [25th, 75th percentile]) between patients exposed to standard (total count: 228 HITS [174, 280]) and SMA circuits (total count: 156 HITS [104, 356]; p = .427). The median of the sum of HITS per patient associated with perfusionist interventions was not different between both circuit groups (standard: 17 HITS [7, 80]; SMA: 43 HITS [13, 168]; p = .085). This study, with a sample size of 28 patients, indicates that it is unlikely to find any difference in the count of HITS during CPB that is greater than 117 HITS between the two CPB circuits. Moreover, our findings emphasize the relevance of minimizing additional sources of cerebral microembolization during CPB that are not directly related to the biocompatible nature of the SMA CPB circuit.


  • Comparison of two different extracorporeal circuits on cerebral embolization during cardiopulmonary bypass in children

    by Rosendo A Rodriguez, Dean Belway

    Objective: To compare the effect of two different extra-corporeal circuits on the counts of high-intensity transient signals (HITS) during pediatric cardiopulmonary bypass (CPB). Methods: Transcranial Doppler was used to detect HITS associated with extracorporeal sources during the period of aortic crossclamping in the middle cerebral artery of children undergoing CPB. Based on body size, children were assigned one of two extracorporeal circuits (A or B). Circuit A included a D-705 oxygenator and associated reservoir, and circuit B included a Lilliput oxygenator and reservoir. Patients were further classified into two groups according to the complexity of surgical repair: single simple lesions or multiple complex lesions. Results: We studied 109 pediatric patients. Surgery for multiple complex lesions was associated with longer periods of aortic crossclamping and CPB (p <0.0001). The median count of extra-corporeal HITS was 12 (25th, 75th percentiles: 3, 51). The type of extracorporeal circuit (p=0.012) and the complexity of surgical repair (p <0.0001) had an effect on the HITS counts. The use of circuit A was associated with higher HITS counts during surgery for multiple complex lesions compared to single simple lesions (p 0.25). During surgery for multiple complex lesions, patients treated with circuit A showed higher HITS counts than those with circuit B (p <0.01), but there were no circuit-related differences in HITS counts (p=0.30) during single simple lesions. Conclusion: Variations in the design characteristics of extracorporeal circuits can increase cerebral emboli during CPB in children. This may be related to the reduced ability of some circuits to remove emboli during long periods of CPB for complex congenital heart-surgery.


  • Sources of Variability in the Detection of Cerebral Emboli with Transcranial Doppler During Cardiac Surgery

    by Rosendo A. Rodriguez, Fraser Rubens, Carlos D. Rodriguez, Howard J. Nathan

    Objective. The application of intensity thresholds for embolus detection with transcranial Doppler (TCD) can exclude from analysis an unrecognized proportion of high‐intensity transient signals (HITS))whose intensities are below the threshold. The lack of consistent threshold criteria between clinical trials may explain part of the discrepancy in the reported HITS counts. We investigated the effect of choosing different thresholds on the sensitivity and specificity of detecting HITS during cardiopulmonary bypass (CPB). Methods. Two observers independently analyzed TCD recordings from 8 patients under CPB. Doppler signals were classified as true HITS, equivocal HITS, artifacts, and Doppler speckles according to preestablished criteria. The relative intensity of Doppler signals was measured by two different methods (TCD software vs manual). Receiver Operating Characteristic curves determined the optimal threshold for each of the two intensity methods. Results. Reviewers achieved agreement in 96% of 2190 Doppler signals (κ= 0.90). Relative intensities calculated with the TCD‐software method were 3 dB (95% CI: 3.0‐3.4) higher than the manual method. The optimal threshold was found at 10 dB (sensitivity: 99%; specificity: 90.8%) with the software method and at 7 dB with the manual method (sensitivity: 96%; specificity: 83%). The use of an intensity threshold 2 dB higher than the optimal increased the rejection of true HITS by 8% and 14%, respectively. Conclusions. Using intensity thresholds higher than the optimal for embolus detection decreases HITS counts. Choosing a threshold depends on the type of method used for measuring the signal intensity. Uniform threshold criteria and comparative studies between different Doppler devices are necessary for making clinical trials more comparable.


  • Residual air in the venous cannula increases cerebral embolization at the onset of cardiopulmonary bypass

    by Rosendo A. Rodriguez, Fraser Rubens, Dean Belway, Howard J. Nathan

    When the right atrium (RA) cannula is connected to the venous return line of the cardiopulmonary bypass (CPB) circuit, air is often introduced. Air in the venous cannula may increase cerebral air embolization at initiation of CPB despite the arterial line filter. We measured the volume of air present in the venous cannula after cannulation of the RA. Transcranial Doppler quantified emboli as high-intensity transient-signals (HITS) in both middle-cerebral arteries (MCA) at the beginning of CPB. After RA cannulation, the air column in the venous line was measured and the total volume calculated using the known lumen diameter. CPB onset was defined as the instant when the CPB machine started moving the patient's blood from the RA into the venous reservoir. Starting from CPB onset, HITS were counted: (a) until completion of the first minute on CPB (1-min count) and (b) until aortic cross clamping (pre-clamping count). We studied 135 patients during coronary artery bypass surgery operated on by 10 cardiac surgeons. HITS during onset of CPB were detected in 95% of patients. Median counts were 10 HITS (25th, 75th percentiles: 3, 26) at 1-min and 21 HITS (8, 51) during pre-clamping. A significant correlation was found between the volume of air in the venous cannula and the HITS counts (r=0.524, p<0.0001). Absence of retained air was associated with lower HITS counts [3 HITS (1, 11)] compared with any amount of air [13 HITS (4, 29), p=0.002)]. The volume of air in the venous cannula, the MCA mean blood flow velocity and the pre-clamping time were the only independent predictors of the pre-clamping HITS counts (p<0.001). Air in the venous cannula can result in HITS in the MCA. Minimizing the volume of air introduced into the venous cannula after cannulation of the RA can decrease cerebral air embolization at the beginning of CPB.


  • Effect of perfusionist technique on cerebral embolization during cardiopulmonary bypass

    by Rosendo A Rodriguez, Kathryn A Williams, Andrei Babaev, Fraser Rubens, Howard J Nathan

    Objective: To determine the association between high-intensity transient signals (HITS) and perfusionist interventions, purging techniques, pump flows and venous reservoir blood volume levels during cardiopulmonary bypass. Methods: Transcranial Doppler was used to detect HITS in the middle cerebral artery during the period of aortic crossclamping in patients undergoing coronary artery bypass grafting. Perfusionist-related interventions were recorded and included blood sampling (including the number of times that the oxygenator sampling manifold was purged), drug bolus injections and infusions (vasopressors, crystalloid and mannitol). Pump flows and venous reservoir volume levels were also documented. Results: There were 534 interventions in 90 patients [median number of interventions per patient: 6 (quartiles: 4, 8)]. The median total HITS count from all interventions was 17 (5, 37). This represented 38% of the total HITS counts during aortic crossclamping. Factors contributing to differences in the HITS count included type of intervention ( p<0.0001) and perfusionist (p=0.0012). Blood sampling ( p<0.001) and drug bolus injections (p=0.06) had higher HITS counts per patient than infusions. Repetitive purging significantly increased HITS counts (r=0.74; p<0.001). Purging perfusionists (purging: 1 - 10 times) had higher HITS counts per patient [5 HITS (1, 15) than nonpurgers [0 HITS (0, 1) p800 mL) in the venous reservoir.


  • Human Auditory Evoked Potentials in the Assessment of Brain Function During Major Cardiovascular Surgery

    by Rosendo A. Rodriguez

    Focal neurologic and intellectual deficits or memory problems are relatively frequent after cardiac surgery. These complications have been associated with cerebral hypoperfusion, embolization, and inflammation that occur during or after surgery. Auditory evoked potentials, a neurophysiologic technique that evaluates the function of neural structures from the auditory nerve to the cortex, provide useful information about the functional status of the brain during major cardiovascular procedures. Skepticism regarding the presence of artifacts or difficulty in their interpretation has outweighed considerations of its potential utility and noninvasiveness. This paper reviews the evidence of their potential applications in several aspects of the management of cardiac surgery patients. The sensitivity of auditory evoked potentials to the effects of changes in brain temperature makes them useful for monitoring cerebral hypothermia and rewarming during cardiopulmonary bypass. The close relationship between evoked potential waveforms and specific anatomic structures facilitates the assessment of the functional integrity of the central nervous system in cardiac surgery patients. This feature may also be relevant in the management of critical patients under sedation and coma or in the evaluation of their prognosis during critical care. Their objectivity, reproducibility, and relative insensitivity to learning effects make auditory evoked potentials attractive for the cognitive assessment of cardiac surgery patients. From a clinical perspective, auditory evoked potentials represent an additional window for the study of underlying cerebral processes in healthy and diseased patients. From a research standpoint, this technology offers opportunities for a better understanding of the particular cerebral deficits associated with patients who are undergoing major cardiovascular procedures.